1SDA068059R1 ABB - XT3N 250 TMD 250-2500 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
6e02ed7f-17b7-4341-9a54-addfe501266a Italy
Simplified SCIP:
c67c1509-1fb8-4452-a702-0b07f01fbbec Germany
d4f45baa-ea21-4c9e-9189-1b75dc080893 Spain
dd18c2d5-d07c-4f4a-9537-929096aa340a Netherlands
c2c064b4-68e9-444e-b795-3162405604d5 Netherlands
7f17ec9d-7631-4488-b853-4de4c94aa81c Germany
e4d6c1d5-5cd1-4ae7-9434-ae519f839247 Sweden
f2253e3c-e8cf-43e9-ad91-7006b1eda1a3 Denmark
7a06855e-fdcd-42a1-adb4-7a036b2aa2fd Germany
c4c4a8ef-9791-4d17-9b97-88c358732875 Poland
68e4f3ad-03c4-47f8-9732-c2c181bb6d26 Norway
0e4638d5-976e-49c6-b94a-430e73f5e716 Finland
26af04db-d477-408d-b429-c27e7a32b1a8 Netherlands
c7169fb9-353e-4ad1-a7b9-f55758d503ba Croatia
9690de18-268a-4812-a2e9-4cfc22c37060 Czech Republic
73a45bca-2680-4dd9-9d08-e5d52bef7b1a Poland
4fdf049f-4055-437f-b00c-732b3a20971e Netherlands
016b2e28-6f0e-43af-991e-8acac3433e5b Estonia
ecb4b84a-ea71-4e87-8f8e-c9095f385895 Greece
c11f564b-92ab-437b-8c0b-66c533b18139 Portugal
c9c2a2c8-b424-42d1-b418-62bc7e3336c2 Bulgaria
f17b83a9-6cf5-4ed8-9a8a-ad5bf35821ca Sweden
338fe678-9ff9-475b-b4c5-488832a7dc4a Poland
2ecaed7e-730d-48c1-95f8-4f5d8dbb6f04 France
854d4adb-7062-4e49-9888-eba42ff7a55f Germany
fe453ba5-5af8-4dd1-829f-e48ec3218a3b Germany
e9f8710e-d4ea-4b03-8e77-b1e789d499f6 France
228278be-3f3c-4121-ab92-d00b43371275 Netherlands
c67c1509-1fb8-4452-a702-0b07f01fbbec Germany
d4f45baa-ea21-4c9e-9189-1b75dc080893 Spain
dd18c2d5-d07c-4f4a-9537-929096aa340a Netherlands
c2c064b4-68e9-444e-b795-3162405604d5 Netherlands
7f17ec9d-7631-4488-b853-4de4c94aa81c Germany
e4d6c1d5-5cd1-4ae7-9434-ae519f839247 Sweden
f2253e3c-e8cf-43e9-ad91-7006b1eda1a3 Denmark
7a06855e-fdcd-42a1-adb4-7a036b2aa2fd Germany
c4c4a8ef-9791-4d17-9b97-88c358732875 Poland
68e4f3ad-03c4-47f8-9732-c2c181bb6d26 Norway

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NE3250AFF000XXX
E-Number (Finland):
3641005
E-Number (Norway):
4309663
E-Number (Sweden):
3182434
EAN:
8015644019303
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.7 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
1.73 kg
Package Level 1 EAN:
8015644019303

Additional Information

Brand / Label:
ABB
Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 17.8 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
2500 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ABS Certificate:
ATEX Certificate:
BV Certificate:
Declaration of Conformity - CE:
DNV GL Certificate:
EAC Certificate:
GL Certificate:
KC Certificate:
LR Certificate:
RINA Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€259,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€259,95
€0,00
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
6e02ed7f-17b7-4341-9a54-addfe501266a Italy
Simplified SCIP:
c67c1509-1fb8-4452-a702-0b07f01fbbec Germany
d4f45baa-ea21-4c9e-9189-1b75dc080893 Spain
dd18c2d5-d07c-4f4a-9537-929096aa340a Netherlands
c2c064b4-68e9-444e-b795-3162405604d5 Netherlands
7f17ec9d-7631-4488-b853-4de4c94aa81c Germany
e4d6c1d5-5cd1-4ae7-9434-ae519f839247 Sweden
f2253e3c-e8cf-43e9-ad91-7006b1eda1a3 Denmark
7a06855e-fdcd-42a1-adb4-7a036b2aa2fd Germany
c4c4a8ef-9791-4d17-9b97-88c358732875 Poland
68e4f3ad-03c4-47f8-9732-c2c181bb6d26 Norway
0e4638d5-976e-49c6-b94a-430e73f5e716 Finland
26af04db-d477-408d-b429-c27e7a32b1a8 Netherlands
c7169fb9-353e-4ad1-a7b9-f55758d503ba Croatia
9690de18-268a-4812-a2e9-4cfc22c37060 Czech Republic
73a45bca-2680-4dd9-9d08-e5d52bef7b1a Poland
4fdf049f-4055-437f-b00c-732b3a20971e Netherlands
016b2e28-6f0e-43af-991e-8acac3433e5b Estonia
ecb4b84a-ea71-4e87-8f8e-c9095f385895 Greece
c11f564b-92ab-437b-8c0b-66c533b18139 Portugal
c9c2a2c8-b424-42d1-b418-62bc7e3336c2 Bulgaria
f17b83a9-6cf5-4ed8-9a8a-ad5bf35821ca Sweden
338fe678-9ff9-475b-b4c5-488832a7dc4a Poland
2ecaed7e-730d-48c1-95f8-4f5d8dbb6f04 France
854d4adb-7062-4e49-9888-eba42ff7a55f Germany
fe453ba5-5af8-4dd1-829f-e48ec3218a3b Germany
e9f8710e-d4ea-4b03-8e77-b1e789d499f6 France
228278be-3f3c-4121-ab92-d00b43371275 Netherlands
c67c1509-1fb8-4452-a702-0b07f01fbbec Germany
d4f45baa-ea21-4c9e-9189-1b75dc080893 Spain
dd18c2d5-d07c-4f4a-9537-929096aa340a Netherlands
c2c064b4-68e9-444e-b795-3162405604d5 Netherlands
7f17ec9d-7631-4488-b853-4de4c94aa81c Germany
e4d6c1d5-5cd1-4ae7-9434-ae519f839247 Sweden
f2253e3c-e8cf-43e9-ad91-7006b1eda1a3 Denmark
7a06855e-fdcd-42a1-adb4-7a036b2aa2fd Germany
c4c4a8ef-9791-4d17-9b97-88c358732875 Poland
68e4f3ad-03c4-47f8-9732-c2c181bb6d26 Norway

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NE3250AFF000XXX
E-Number (Finland):
3641005
E-Number (Norway):
4309663
E-Number (Sweden):
3182434
EAN:
8015644019303
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.7 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
1.73 kg
Package Level 1 EAN:
8015644019303

Additional Information

Brand / Label:
ABB
Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 17.8 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
2500 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ABS Certificate:
ATEX Certificate:
BV Certificate:
Declaration of Conformity - CE:
DNV GL Certificate:
EAC Certificate:
GL Certificate:
KC Certificate:
LR Certificate:
RINA Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator