1SDA067553R1 ABB

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
ce23f4ae-35ba-49ba-8bcb-1af092fb2c20 Italy
Simplified SCIP:
2b5eaa92-205a-40b9-bca7-7e52401ac428 France
23e1caf1-645d-4011-b1bd-567a512901dc Spain
ee5b4bb6-f1fb-4651-a746-778bd2eeb374 Hungary
8776e078-a8b0-432d-b5bd-b8361a90fe23 Belgium
cafa272f-e73a-473a-8f7f-dc8cd63278f4 Germany
ea8a9633-732a-4fd2-b78c-da111d5b6bbe Czech Republic
c2ab4b42-18f9-4042-9282-9aae651f22d8 Sweden
542b5cb7-04e5-4e34-854d-6157c44a31e7 Portugal
75364400-521b-471c-b1ac-4ffbb6824e70 Denmark
6239c29b-966e-45a7-b632-beaf0e63c84b Germany
733b23bd-e75a-4f1a-873a-95c5313bc5b4 Germany
043c41c4-6240-457e-b330-9093b5fd26c3 Croatia
f60ba0b2-b2ed-48f3-a498-9c2b23430b2b Germany
1db306bb-beec-4694-aea5-39a6e0bbf82d Norway
8801ee98-b3a8-4b58-9e4b-67a12206e7ed Netherlands
095641cf-77ae-4600-bb35-87c96dbe5444 Sweden
aa6fb5a3-0908-467d-a472-03f2f23ade01 Bulgaria
be054cbb-d051-46bf-940d-3051d79d0240 Poland
19359a19-6b7b-405d-af0d-45756d0b1630 Poland
f31eb2c5-8f6a-4af3-9a27-89b88358c8de Hungary
bee6c10f-1483-4f75-829a-a9a816a20ec9 Poland
c778cea7-8f44-48f5-be7d-61a151c865bf Finland
633608f6-ccb8-48c3-808c-c45159d9ab2c Estonia
891d9794-1b6c-40b5-8af5-b35b1da4af6a Belgium
5a5a49df-463d-4317-9073-0b0d161b6222 Germany
8d288905-05d5-4fdb-90ba-9570c71f0ab6 Greece
1bfc0c02-fab0-49b1-8a3c-dfe1a09a50c6 France
2b5eaa92-205a-40b9-bca7-7e52401ac428 France
23e1caf1-645d-4011-b1bd-567a512901dc Spain
ee5b4bb6-f1fb-4651-a746-778bd2eeb374 Hungary
8776e078-a8b0-432d-b5bd-b8361a90fe23 Belgium
cafa272f-e73a-473a-8f7f-dc8cd63278f4 Germany
ea8a9633-732a-4fd2-b78c-da111d5b6bbe Czech Republic
c2ab4b42-18f9-4042-9282-9aae651f22d8 Sweden
542b5cb7-04e5-4e34-854d-6157c44a31e7 Portugal
75364400-521b-471c-b1ac-4ffbb6824e70 Denmark
6239c29b-966e-45a7-b632-beaf0e63c84b Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE3032AFF000XXX
E-Number (Finland):
3638611
E-Number (Norway):
4379273
EAN:
8015644014490
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
90 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
130 mm
Package Level 1 Height:
208 mm
Package Level 1 Depth / Length:
145 mm
Package Level 1 Gross Weight:
1.664 kg
Package Level 1 EAN:
8015644014490

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 2.57 W
Rated Current (In):
32 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
320 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
22.4...32 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€160,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€160,95
€0,00
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
ce23f4ae-35ba-49ba-8bcb-1af092fb2c20 Italy
Simplified SCIP:
2b5eaa92-205a-40b9-bca7-7e52401ac428 France
23e1caf1-645d-4011-b1bd-567a512901dc Spain
ee5b4bb6-f1fb-4651-a746-778bd2eeb374 Hungary
8776e078-a8b0-432d-b5bd-b8361a90fe23 Belgium
cafa272f-e73a-473a-8f7f-dc8cd63278f4 Germany
ea8a9633-732a-4fd2-b78c-da111d5b6bbe Czech Republic
c2ab4b42-18f9-4042-9282-9aae651f22d8 Sweden
542b5cb7-04e5-4e34-854d-6157c44a31e7 Portugal
75364400-521b-471c-b1ac-4ffbb6824e70 Denmark
6239c29b-966e-45a7-b632-beaf0e63c84b Germany
733b23bd-e75a-4f1a-873a-95c5313bc5b4 Germany
043c41c4-6240-457e-b330-9093b5fd26c3 Croatia
f60ba0b2-b2ed-48f3-a498-9c2b23430b2b Germany
1db306bb-beec-4694-aea5-39a6e0bbf82d Norway
8801ee98-b3a8-4b58-9e4b-67a12206e7ed Netherlands
095641cf-77ae-4600-bb35-87c96dbe5444 Sweden
aa6fb5a3-0908-467d-a472-03f2f23ade01 Bulgaria
be054cbb-d051-46bf-940d-3051d79d0240 Poland
19359a19-6b7b-405d-af0d-45756d0b1630 Poland
f31eb2c5-8f6a-4af3-9a27-89b88358c8de Hungary
bee6c10f-1483-4f75-829a-a9a816a20ec9 Poland
c778cea7-8f44-48f5-be7d-61a151c865bf Finland
633608f6-ccb8-48c3-808c-c45159d9ab2c Estonia
891d9794-1b6c-40b5-8af5-b35b1da4af6a Belgium
5a5a49df-463d-4317-9073-0b0d161b6222 Germany
8d288905-05d5-4fdb-90ba-9570c71f0ab6 Greece
1bfc0c02-fab0-49b1-8a3c-dfe1a09a50c6 France
2b5eaa92-205a-40b9-bca7-7e52401ac428 France
23e1caf1-645d-4011-b1bd-567a512901dc Spain
ee5b4bb6-f1fb-4651-a746-778bd2eeb374 Hungary
8776e078-a8b0-432d-b5bd-b8361a90fe23 Belgium
cafa272f-e73a-473a-8f7f-dc8cd63278f4 Germany
ea8a9633-732a-4fd2-b78c-da111d5b6bbe Czech Republic
c2ab4b42-18f9-4042-9282-9aae651f22d8 Sweden
542b5cb7-04e5-4e34-854d-6157c44a31e7 Portugal
75364400-521b-471c-b1ac-4ffbb6824e70 Denmark
6239c29b-966e-45a7-b632-beaf0e63c84b Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE3032AFF000XXX
E-Number (Finland):
3638611
E-Number (Norway):
4379273
EAN:
8015644014490
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
90 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
130 mm
Package Level 1 Height:
208 mm
Package Level 1 Depth / Length:
145 mm
Package Level 1 Gross Weight:
1.664 kg
Package Level 1 EAN:
8015644014490

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 2.57 W
Rated Current (In):
32 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
320 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
22.4...32 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator