1SDA067440R1 ABB - XT1S 160 TMD 63-630 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
a64a71c8-2a15-484d-aa7f-726507440e44 Italy
Simplified SCIP:
fd03284a-b46f-46b9-af63-69b3b4762aea Germany
280ded22-e263-4e3b-b81c-9084d4308385 Poland
7b05548a-e015-4945-a79f-2075289b925a Poland
bf94d655-349c-44b7-bd29-3f75bc860916 Bulgaria
c5639dac-4194-430c-a23f-3252ebbca1ef Portugal
b148701a-d8a8-4c5a-b3fa-73c59b7d9174 Hungary
35940b5c-2b3e-4270-bb06-e7e2588b2137 Belgium
3db23266-a43d-4a48-b738-917d8ef907d2 Spain
fa34b4e5-6ac3-4154-912d-a510aecaae6a France
459dd98a-1407-4239-a2fb-05dca88961c0 Germany
3457a8bb-56ed-4ecf-a190-f9bdff93df8c Denmark
43573122-88b5-4317-b9b8-08c0212e9206 Sweden
08bf8494-6075-4c06-bc4f-84d4fbb5915b Germany
5f0b1111-d6a8-474c-8727-03eeac4a21ac Germany
913aecfc-7aab-4baa-b645-2130b8975519 Croatia
054527a7-cebf-473b-bd8a-ed748d883693 Czech Republic
34621fae-58d0-4e90-ae40-952bbbc2dd12 Germany
5d29a269-d245-4a5d-926d-e6dd438fb713 Greece
c833f4e3-5422-4210-8f33-1c3a1d8010c1 France
f6a3be32-6ea4-4c7d-b3e9-6ea5abbdcd1d Belgium
dcdd5d0e-c6d7-489e-81d4-9baa8bdcf944 Estonia
48b75ddc-93dc-49ba-9951-af1ca9494921 Hungary
adafc7c9-e8aa-4762-82fe-c974d4985d62 Poland
92a6b06c-f3b1-41e3-a241-8e6ad9d7dbd3 Sweden
514cb359-ef47-455e-90f2-c4935727278e Finland
7dd0bde2-1f35-45fe-b751-a1fb27f7df16 Norway
9e8d7d74-0f78-4696-a3c1-19b336ffd2de Netherlands
fd03284a-b46f-46b9-af63-69b3b4762aea Germany
280ded22-e263-4e3b-b81c-9084d4308385 Poland
7b05548a-e015-4945-a79f-2075289b925a Poland
bf94d655-349c-44b7-bd29-3f75bc860916 Bulgaria
c5639dac-4194-430c-a23f-3252ebbca1ef Portugal
b148701a-d8a8-4c5a-b3fa-73c59b7d9174 Hungary
35940b5c-2b3e-4270-bb06-e7e2588b2137 Belgium
3db23266-a43d-4a48-b738-917d8ef907d2 Spain
fa34b4e5-6ac3-4154-912d-a510aecaae6a France
459dd98a-1407-4239-a2fb-05dca88961c0 Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1SE4063AFF000XXX
E-Number (Norway):
4309721
EAN:
8015644013349
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.4 kg
Package Level 1 EAN:
8015644013349

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
630 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 80 kA
(230 V AC) 80 kA
(240 V AC) 80 kA
(380 V AC) 50 kA
(415 V AC) 37.5 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 17.5 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 80 kA
(230 V AC) 80 kA
(240 V AC) 80 kA
(380 V AC) 50 kA
(415 V AC) 37.5 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 17.5 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 35 kA
(690 V AC) 8 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 35 kA
(690 V AC) 8 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€468,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€0,00
€468,95
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
a64a71c8-2a15-484d-aa7f-726507440e44 Italy
Simplified SCIP:
fd03284a-b46f-46b9-af63-69b3b4762aea Germany
280ded22-e263-4e3b-b81c-9084d4308385 Poland
7b05548a-e015-4945-a79f-2075289b925a Poland
bf94d655-349c-44b7-bd29-3f75bc860916 Bulgaria
c5639dac-4194-430c-a23f-3252ebbca1ef Portugal
b148701a-d8a8-4c5a-b3fa-73c59b7d9174 Hungary
35940b5c-2b3e-4270-bb06-e7e2588b2137 Belgium
3db23266-a43d-4a48-b738-917d8ef907d2 Spain
fa34b4e5-6ac3-4154-912d-a510aecaae6a France
459dd98a-1407-4239-a2fb-05dca88961c0 Germany
3457a8bb-56ed-4ecf-a190-f9bdff93df8c Denmark
43573122-88b5-4317-b9b8-08c0212e9206 Sweden
08bf8494-6075-4c06-bc4f-84d4fbb5915b Germany
5f0b1111-d6a8-474c-8727-03eeac4a21ac Germany
913aecfc-7aab-4baa-b645-2130b8975519 Croatia
054527a7-cebf-473b-bd8a-ed748d883693 Czech Republic
34621fae-58d0-4e90-ae40-952bbbc2dd12 Germany
5d29a269-d245-4a5d-926d-e6dd438fb713 Greece
c833f4e3-5422-4210-8f33-1c3a1d8010c1 France
f6a3be32-6ea4-4c7d-b3e9-6ea5abbdcd1d Belgium
dcdd5d0e-c6d7-489e-81d4-9baa8bdcf944 Estonia
48b75ddc-93dc-49ba-9951-af1ca9494921 Hungary
adafc7c9-e8aa-4762-82fe-c974d4985d62 Poland
92a6b06c-f3b1-41e3-a241-8e6ad9d7dbd3 Sweden
514cb359-ef47-455e-90f2-c4935727278e Finland
7dd0bde2-1f35-45fe-b751-a1fb27f7df16 Norway
9e8d7d74-0f78-4696-a3c1-19b336ffd2de Netherlands
fd03284a-b46f-46b9-af63-69b3b4762aea Germany
280ded22-e263-4e3b-b81c-9084d4308385 Poland
7b05548a-e015-4945-a79f-2075289b925a Poland
bf94d655-349c-44b7-bd29-3f75bc860916 Bulgaria
c5639dac-4194-430c-a23f-3252ebbca1ef Portugal
b148701a-d8a8-4c5a-b3fa-73c59b7d9174 Hungary
35940b5c-2b3e-4270-bb06-e7e2588b2137 Belgium
3db23266-a43d-4a48-b738-917d8ef907d2 Spain
fa34b4e5-6ac3-4154-912d-a510aecaae6a France
459dd98a-1407-4239-a2fb-05dca88961c0 Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1SE4063AFF000XXX
E-Number (Norway):
4309721
EAN:
8015644013349
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.4 kg
Package Level 1 EAN:
8015644013349

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
630 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 80 kA
(230 V AC) 80 kA
(240 V AC) 80 kA
(380 V AC) 50 kA
(415 V AC) 37.5 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 17.5 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 80 kA
(230 V AC) 80 kA
(240 V AC) 80 kA
(380 V AC) 50 kA
(415 V AC) 37.5 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 17.5 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 35 kA
(690 V AC) 8 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 35 kA
(690 V AC) 8 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator