1SDA067037R1 ABB - XT2N 160 TMA 63-630 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
01957bb2-d604-48b2-a2e1-50857b7b64fb Italy
Simplified SCIP:
6cf4007d-7377-4620-bf71-bb2ebfb8139e Spain
b97116df-e458-4bba-abf2-6ef281595902 Hungary
ed4e22aa-68ca-4777-b4a3-9a7707e660a7 Belgium
2ee5ac5d-2089-489a-bc81-a27283b6a9f5 France
2059c5b2-4ac5-457f-bbfd-e7a64624a00e Germany
9113dc5a-7d1b-4ba0-b42f-5c3aad75a719 Czech Republic
60c32cd6-3bb5-499c-a2ff-ac53a0e9ee96 Portugal
7d5e121e-4036-4866-bca5-9669e1b6aa96 Denmark
19a3b1f0-c617-477e-a82a-b06c5a5ada60 Germany
339468d7-c350-48e1-ae79-c8824d81dd69 Sweden
60d4882a-fb2e-45bd-9a25-c977bf022219 Germany
fbcb5e15-7f17-4ec8-a643-ad76a192e56e Croatia
b3344b4b-dd95-4b8f-ac56-bc55a64e7145 France
e79caf94-a678-44d2-b167-ccd62089f529 Greece
cbdaf91b-fc37-4d44-bc24-1b84f8b98589 Estonia
0e163568-64b1-45c3-ab3c-8a1bf267d2c0 Belgium
02103868-adaa-4982-9bb7-910cc86142d1 Finland
dde684a3-60de-42cd-8fe1-f519a19f95e3 Poland
a97f8077-2b79-41ef-aacf-546fa724843b Hungary
5c0bf06a-3071-46b7-9cf6-2e017c00ad8c Sweden
651ec6b9-af35-42a6-a44f-2e7bf9de6186 Germany
25ea3b9c-a250-40d0-ab4d-a5ee6f855790 Norway
7b1d9aba-e4e1-47e1-b92e-6549d454ea1f Netherlands
033d7a16-0c77-45ae-bcdd-8641cae11075 Poland
fbc82c32-a5ca-44b9-b720-8beb14dc2c52 Poland
38cc79c8-82f9-42b9-a19e-983ed2688685 Bulgaria
c219e422-f6f7-467c-806d-a14a0ad81bed Germany
6cf4007d-7377-4620-bf71-bb2ebfb8139e Spain
b97116df-e458-4bba-abf2-6ef281595902 Hungary
ed4e22aa-68ca-4777-b4a3-9a7707e660a7 Belgium
2ee5ac5d-2089-489a-bc81-a27283b6a9f5 France
2059c5b2-4ac5-457f-bbfd-e7a64624a00e Germany
9113dc5a-7d1b-4ba0-b42f-5c3aad75a719 Czech Republic
60c32cd6-3bb5-499c-a2ff-ac53a0e9ee96 Portugal
7d5e121e-4036-4866-bca5-9669e1b6aa96 Denmark
19a3b1f0-c617-477e-a82a-b06c5a5ada60 Germany
339468d7-c350-48e1-ae79-c8824d81dd69 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2NE4063BFF000XXX
E-Number (Norway):
4309742
EAN:
8015644009434
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
120 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.6 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
130 mm
Package Level 1 Height:
208 mm
Package Level 1 Depth / Length:
145 mm
Package Level 1 Gross Weight:
2.114 kg
Package Level 1 EAN:
8015644009434

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.85 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
300…630 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMA
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€239,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€239,95
€0,00
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
01957bb2-d604-48b2-a2e1-50857b7b64fb Italy
Simplified SCIP:
6cf4007d-7377-4620-bf71-bb2ebfb8139e Spain
b97116df-e458-4bba-abf2-6ef281595902 Hungary
ed4e22aa-68ca-4777-b4a3-9a7707e660a7 Belgium
2ee5ac5d-2089-489a-bc81-a27283b6a9f5 France
2059c5b2-4ac5-457f-bbfd-e7a64624a00e Germany
9113dc5a-7d1b-4ba0-b42f-5c3aad75a719 Czech Republic
60c32cd6-3bb5-499c-a2ff-ac53a0e9ee96 Portugal
7d5e121e-4036-4866-bca5-9669e1b6aa96 Denmark
19a3b1f0-c617-477e-a82a-b06c5a5ada60 Germany
339468d7-c350-48e1-ae79-c8824d81dd69 Sweden
60d4882a-fb2e-45bd-9a25-c977bf022219 Germany
fbcb5e15-7f17-4ec8-a643-ad76a192e56e Croatia
b3344b4b-dd95-4b8f-ac56-bc55a64e7145 France
e79caf94-a678-44d2-b167-ccd62089f529 Greece
cbdaf91b-fc37-4d44-bc24-1b84f8b98589 Estonia
0e163568-64b1-45c3-ab3c-8a1bf267d2c0 Belgium
02103868-adaa-4982-9bb7-910cc86142d1 Finland
dde684a3-60de-42cd-8fe1-f519a19f95e3 Poland
a97f8077-2b79-41ef-aacf-546fa724843b Hungary
5c0bf06a-3071-46b7-9cf6-2e017c00ad8c Sweden
651ec6b9-af35-42a6-a44f-2e7bf9de6186 Germany
25ea3b9c-a250-40d0-ab4d-a5ee6f855790 Norway
7b1d9aba-e4e1-47e1-b92e-6549d454ea1f Netherlands
033d7a16-0c77-45ae-bcdd-8641cae11075 Poland
fbc82c32-a5ca-44b9-b720-8beb14dc2c52 Poland
38cc79c8-82f9-42b9-a19e-983ed2688685 Bulgaria
c219e422-f6f7-467c-806d-a14a0ad81bed Germany
6cf4007d-7377-4620-bf71-bb2ebfb8139e Spain
b97116df-e458-4bba-abf2-6ef281595902 Hungary
ed4e22aa-68ca-4777-b4a3-9a7707e660a7 Belgium
2ee5ac5d-2089-489a-bc81-a27283b6a9f5 France
2059c5b2-4ac5-457f-bbfd-e7a64624a00e Germany
9113dc5a-7d1b-4ba0-b42f-5c3aad75a719 Czech Republic
60c32cd6-3bb5-499c-a2ff-ac53a0e9ee96 Portugal
7d5e121e-4036-4866-bca5-9669e1b6aa96 Denmark
19a3b1f0-c617-477e-a82a-b06c5a5ada60 Germany
339468d7-c350-48e1-ae79-c8824d81dd69 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2NE4063BFF000XXX
E-Number (Norway):
4309742
EAN:
8015644009434
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
120 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.6 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
130 mm
Package Level 1 Height:
208 mm
Package Level 1 Depth / Length:
145 mm
Package Level 1 Gross Weight:
2.114 kg
Package Level 1 EAN:
8015644009434

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.85 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
300…630 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMA
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator