1SDA066807R1 ABB

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
87da4ae5-d281-4cf7-89ae-08ea1f34c520 Italy
Simplified SCIP:
e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany
9136ee1a-0225-4485-8008-9b9b4f898003 France
baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands
19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain
0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands
1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia
3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece
b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal
40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria
34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden
7688f27b-0303-4931-a1b9-201ec758eed9 Poland
2973e92d-a825-4905-b178-8271043cd3fc Netherlands
88dd4d2a-48ef-40e5-a5a4-8777e0caf1ae Poland
28af0011-3352-4568-ae2e-5c6f712f69ce Norway
139a4e60-c144-4385-9f47-109d95a5e80f Finland
fdaa062c-f086-4a1a-84ad-e07827068768 Netherlands
b45b713c-aac6-486d-860d-62c7bd566c76 Germany
7cd9e27b-8379-4d1d-9c10-2494ae68a5e5 Denmark
b5672789-5124-44cd-b9aa-10e3f35aba7a Germany
4b159a82-b08b-4bd6-9325-11ce5cdf5448 Croatia
dde32885-1587-472c-b2dd-1326e5aad4e2 Czech Republic
f4f530b5-c734-46f4-9e51-1699fa3f6f95 Poland
7684609b-1286-40fa-be35-8e161c571a09 Netherlands
53567a62-c858-4312-a586-9c3dff2aeb2a France
97a62aeb-f463-485d-802c-da5b271e1915 Sweden
706a0ec2-b9e6-48d8-a2e7-e213302d4bc2 Germany
6f865dc7-914e-4ee1-bd3b-f9f2de603622 Germany
e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany
9136ee1a-0225-4485-8008-9b9b4f898003 France
baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands
19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain
0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands
1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia
3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece
b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal
40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria
34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3100AFF000XXX
E-Number (Finland):
3640495
E-Number (Norway):
4309608
EAN:
8015644694487
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.134 kg
Package Level 1 EAN:
8015644694487

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€119,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€119,95
€0,00
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
87da4ae5-d281-4cf7-89ae-08ea1f34c520 Italy
Simplified SCIP:
e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany
9136ee1a-0225-4485-8008-9b9b4f898003 France
baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands
19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain
0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands
1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia
3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece
b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal
40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria
34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden
7688f27b-0303-4931-a1b9-201ec758eed9 Poland
2973e92d-a825-4905-b178-8271043cd3fc Netherlands
88dd4d2a-48ef-40e5-a5a4-8777e0caf1ae Poland
28af0011-3352-4568-ae2e-5c6f712f69ce Norway
139a4e60-c144-4385-9f47-109d95a5e80f Finland
fdaa062c-f086-4a1a-84ad-e07827068768 Netherlands
b45b713c-aac6-486d-860d-62c7bd566c76 Germany
7cd9e27b-8379-4d1d-9c10-2494ae68a5e5 Denmark
b5672789-5124-44cd-b9aa-10e3f35aba7a Germany
4b159a82-b08b-4bd6-9325-11ce5cdf5448 Croatia
dde32885-1587-472c-b2dd-1326e5aad4e2 Czech Republic
f4f530b5-c734-46f4-9e51-1699fa3f6f95 Poland
7684609b-1286-40fa-be35-8e161c571a09 Netherlands
53567a62-c858-4312-a586-9c3dff2aeb2a France
97a62aeb-f463-485d-802c-da5b271e1915 Sweden
706a0ec2-b9e6-48d8-a2e7-e213302d4bc2 Germany
6f865dc7-914e-4ee1-bd3b-f9f2de603622 Germany
e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany
9136ee1a-0225-4485-8008-9b9b4f898003 France
baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands
19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain
0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands
1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia
3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece
b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal
40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria
34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3100AFF000XXX
E-Number (Finland):
3640495
E-Number (Norway):
4309608
EAN:
8015644694487
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.134 kg
Package Level 1 EAN:
8015644694487

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator