1SBL387001R1200 ABB - AF65-30-00-12

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.97 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
3fec47c1-c65d-4305-9c2e-7df042a1cddc China
Simplified SCIP:
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
f17ed004-abba-409b-a805-15157aa55e3a Germany
bc1ad85e-d612-47e6-97e2-5de4b0fa54be Sweden
c92a120b-91ae-4036-a235-6fe1cdaa62ab France
8c38c27a-ad0d-417a-9d95-acad06fa6062 Germany
ac1e48ae-9d93-463a-93d6-ddcba42a4a00 Spain
0293f116-3a57-479f-9fa2-8c8d8487a6fb Belgium
56cd4198-8e96-4f6d-97de-c408253f9825 Portugal
44049422-87ff-4bac-bd16-be9d1b535380 Germany
bcc1f3eb-a8a8-44a8-b43f-1899bcaf6d00 Greece
b1bfb508-b884-456c-a369-ae91028a4c67 Bulgaria
b97cfb2f-06b1-4231-94dd-ebc2b2e51de3 Hungary
8042fc92-672d-4056-b2ee-c30c715d04df Norway
11871a04-5b59-4c36-857a-37307ce804cb Netherlands
3d6e31e2-8770-4907-9552-191b765cbc0f Poland
5ac7a695-f072-44eb-a881-5471b74ec908 Finland
d223af47-6a31-49a2-96e0-bdb74606c444 Estonia
a4b16553-4a18-4d45-b271-0f89e979bae1 Hungary
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.07 kg
Package Level 1 EAN:
3471523132627
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.7 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707047
E-Number (Sweden):
3210043
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price€333,95
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
€0,00
€333,95
€0,00
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.97 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
3fec47c1-c65d-4305-9c2e-7df042a1cddc China
Simplified SCIP:
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
f17ed004-abba-409b-a805-15157aa55e3a Germany
bc1ad85e-d612-47e6-97e2-5de4b0fa54be Sweden
c92a120b-91ae-4036-a235-6fe1cdaa62ab France
8c38c27a-ad0d-417a-9d95-acad06fa6062 Germany
ac1e48ae-9d93-463a-93d6-ddcba42a4a00 Spain
0293f116-3a57-479f-9fa2-8c8d8487a6fb Belgium
56cd4198-8e96-4f6d-97de-c408253f9825 Portugal
44049422-87ff-4bac-bd16-be9d1b535380 Germany
bcc1f3eb-a8a8-44a8-b43f-1899bcaf6d00 Greece
b1bfb508-b884-456c-a369-ae91028a4c67 Bulgaria
b97cfb2f-06b1-4231-94dd-ebc2b2e51de3 Hungary
8042fc92-672d-4056-b2ee-c30c715d04df Norway
11871a04-5b59-4c36-857a-37307ce804cb Netherlands
3d6e31e2-8770-4907-9552-191b765cbc0f Poland
5ac7a695-f072-44eb-a881-5471b74ec908 Finland
d223af47-6a31-49a2-96e0-bdb74606c444 Estonia
a4b16553-4a18-4d45-b271-0f89e979bae1 Hungary
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.07 kg
Package Level 1 EAN:
3471523132627
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.7 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707047
E-Number (Sweden):
3210043
Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707047
E-Number (Sweden):
3210043

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator