1SAH107171R9900 ABB - MCRC022ATWJ

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Dimensions

Product Net Width:
45 mm
Product Net Depth / Length:
68 mm
Product Net Height:
48 mm
Product Net Weight:
0.235 kg

Technical

Number of Main Contacts NO:
0
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
2
Number of Auxiliary Contacts NC:
2
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-5-1
IEC/EN 60947-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-5-1
Rated Operational Voltage:
Auxiliary Circuit 690 V AC
Auxiliary Circuit 440 V DC
Auxiliary Circuit 690 V AC
Auxiliary Circuit 440 V DC
Rated Frequency (f):
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit DC
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit DC
Conventional Free-air Thermal Current (Ith):
Auxiliary Circuit 10 A
Rated Operational Current AC-15 (Ie):
(240 V) 6 A
(400 V) 4 A
(500 V) 2.5 A
(690 V) 1.5 A
(240 V) 6 A
(400 V) 4 A
(500 V) 2.5 A
(690 V) 1.5 A
Rated Operational Current DC-13 (Ie):
(24 V) 5 A
(48 V) 2.5 A
(125 V) 0.55 A
(250 V) 0.3 A
(440 V) 0.15 A
(24 V) 5 A
(48 V) 2.5 A
(125 V) 0.55 A
(250 V) 0.3 A
(440 V) 0.15 A
Short-Circuit Protective Devices:
gG Type Fuses 10 A
Rated Insulation Voltage (Ui):
750 V
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency:
(AC-15) 360 cycles per hour
(DC-13) 360 cycles per hour
(AC-15) 360 cycles per hour
(DC-13) 360 cycles per hour
Mechanical Durability:
Nr. Operations 10000000 cycle
Minimum Switching Capacity:
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Coil Operating Limits:
(acc. to IEC 60947-5-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
110 V DC
Coil Consumption:
Average Holding Value DC 4 W
Average Pull-in Value DC 4 W
Average Holding Value DC 4 W
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions per Pole 0.4 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1x 0.75 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1x 0.75 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 9 mm
Control Circuit 9 mm
Auxiliary Circuit 9 mm
Control Circuit 9 mm
Degree of Protection:
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Recommended Screw Driver:
Pozidriv 2
Tightening Torque:
Auxiliary Circuit 0.8 ... 1.0 N·m
Control Circuit 0.8 N·m
Auxiliary Circuit 0.8 ... 1.0 N·m
Control Circuit 0.8 N·m
Terminal Type:
Screw Terminals
Mini Contactor Type:
Mini Contactor Relay
Product Name:
Mini Contactor Relay

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
600 V AC
General Use Rating UL/CSA:
(600 V AC) 10 A
Connecting Capacity Auxiliary Circuit UL/CSA:
Stranded 1/2x 18-12 AWG
Contact Rating UL/CSA:
A600
Q600
A600
Q600
Tightening Torque UL/CSA:
Auxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb
Auxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb

Environmental

Ambient Air Temperature:
Operation -40 ... +70 °C
Storage -55 ... +80 °C
Operation -40 ... +70 °C
Storage -55 ... +80 °C
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
5g 3 ... 150 Hz

Material Compliance

Certificates and Declarations

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
46 mm
Package Level 1 Depth / Length:
49 mm
Package Level 1 Height:
70 mm
Package Level 1 Gross Weight:
0.24 kg
Package Level 1 EAN:
4013614547164
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
243 mm
Package Level 2 Depth / Length:
106 mm
Package Level 2 Height:
80 mm
Package Level 2 Gross Weight:
2.46 kg
Package Level 2 EAN:
4013614547577

External Classifications and Standards

Object Classification Code:
K
ETIM 7:
EC000196 - Contactor relay
ETIM 8:
EC000196 - Contactor relay
ETIM 9:
EC000196 - Contactor relay
eClass:
V11.0 : 27371001
UNSPSC:
39121500
Price on request
Ask for quote
   

Notify Me When Available

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080

Dimensions

Product Net Width:
45 mm
Product Net Depth / Length:
68 mm
Product Net Height:
48 mm
Product Net Weight:
0.235 kg

Technical

Number of Main Contacts NO:
0
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
2
Number of Auxiliary Contacts NC:
2
Number of Poles:
4P
Standards:
IEC/EN 60947-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-5-1
IEC/EN 60947-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-5-1
Rated Operational Voltage:
Auxiliary Circuit 690 V AC
Auxiliary Circuit 440 V DC
Auxiliary Circuit 690 V AC
Auxiliary Circuit 440 V DC
Rated Frequency (f):
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit DC
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit DC
Conventional Free-air Thermal Current (Ith):
Auxiliary Circuit 10 A
Rated Operational Current AC-15 (Ie):
(240 V) 6 A
(400 V) 4 A
(500 V) 2.5 A
(690 V) 1.5 A
(240 V) 6 A
(400 V) 4 A
(500 V) 2.5 A
(690 V) 1.5 A
Rated Operational Current DC-13 (Ie):
(24 V) 5 A
(48 V) 2.5 A
(125 V) 0.55 A
(250 V) 0.3 A
(440 V) 0.15 A
(24 V) 5 A
(48 V) 2.5 A
(125 V) 0.55 A
(250 V) 0.3 A
(440 V) 0.15 A
Short-Circuit Protective Devices:
gG Type Fuses 10 A
Rated Insulation Voltage (Ui):
750 V
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency:
(AC-15) 360 cycles per hour
(DC-13) 360 cycles per hour
(AC-15) 360 cycles per hour
(DC-13) 360 cycles per hour
Mechanical Durability:
Nr. Operations 10000000 cycle
Minimum Switching Capacity:
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Coil Operating Limits:
(acc. to IEC 60947-5-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc):
110 V DC
Coil Consumption:
Average Holding Value DC 4 W
Average Pull-in Value DC 4 W
Average Holding Value DC 4 W
Average Pull-in Value DC 4 W
Power Loss:
at Rated Operating Conditions per Pole 0.4 W
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1x 0.75 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1x 0.75 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 9 mm
Control Circuit 9 mm
Auxiliary Circuit 9 mm
Control Circuit 9 mm
Degree of Protection:
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Recommended Screw Driver:
Pozidriv 2
Tightening Torque:
Auxiliary Circuit 0.8 ... 1.0 N·m
Control Circuit 0.8 N·m
Auxiliary Circuit 0.8 ... 1.0 N·m
Control Circuit 0.8 N·m
Terminal Type:
Screw Terminals
Mini Contactor Type:
Mini Contactor Relay
Product Name:
Mini Contactor Relay

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
600 V AC
General Use Rating UL/CSA:
(600 V AC) 10 A
Connecting Capacity Auxiliary Circuit UL/CSA:
Stranded 1/2x 18-12 AWG
Contact Rating UL/CSA:
A600
Q600
A600
Q600
Tightening Torque UL/CSA:
Auxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb
Auxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb

Environmental

Ambient Air Temperature:
Operation -40 ... +70 °C
Storage -55 ... +80 °C
Operation -40 ... +70 °C
Storage -55 ... +80 °C
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
5g 3 ... 150 Hz

Material Compliance

Certificates and Declarations

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
46 mm
Package Level 1 Depth / Length:
49 mm
Package Level 1 Height:
70 mm
Package Level 1 Gross Weight:
0.24 kg
Package Level 1 EAN:
4013614547164
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
243 mm
Package Level 2 Depth / Length:
106 mm
Package Level 2 Height:
80 mm
Package Level 2 Gross Weight:
2.46 kg
Package Level 2 EAN:
4013614547577

External Classifications and Standards

Object Classification Code:
K
ETIM 7:
EC000196 - Contactor relay
ETIM 8:
EC000196 - Contactor relay
ETIM 9:
EC000196 - Contactor relay
eClass:
V11.0 : 27371001
UNSPSC:
39121500
Object Classification Code:
K
ETIM 7:
EC000196 - Contactor relay
ETIM 8:
EC000196 - Contactor relay
ETIM 9:
EC000196 - Contactor relay
eClass:
V11.0 : 27371001
UNSPSC:
39121500

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator