keyence Stock Image
Keyence OP-3107 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-3107

Overview

Teflon cap with M14 inner diameter. Protect from weld spatter.

Applicable product

EH-114

Material

PTFE

keyence Stock Image
Keyence NR-CM01 Keyence
Sale price€0,00
Sold Out

Specifications

Model

NR-CM01

Type

Standard model

PC interface

USB communications standard

USB2.0 High Speed

Supported OS

Windows® 11 Home/Pro/Enterprise
Windows® 10 Home/Pro/Enterprise

Power supply

USB bus power

Power consumption

650 mW max.

Image sensor

Color CMOS

Image resolution

Up to 1920 × 1080

Frame rate

Up to 30 fps

Optical performance

Field of view

At 150 mm 5.91" distance:
280 × 160 mm 11.02" × 6.30"
At 300 mm 11.81" distance:
570 × 320 mm 22.44" × 12.60"
At 1000 mm 39.37" distance:
1900 × 1070 mm 74.80" × 42.13"
*1

Installation distance

150 mm 5.91" or more

Environmental resistance

Enclosure rating

IP67

Ambient temperature

−20 to 55°C −4°F to 131°F (no freezing)

Relative humidity

85% RH or less (no condensation)

Material

Body: Aluminum, Window: Acrylic, Connector: Brass (nickel plated)

Weight

Approx. 120 g 4.23 oz

*1 Fields of view are reference values.

keyence Stock Image
Keyence CL-EC100 Keyence
Sale price €3.765,95
Only 2 units left

Specifications

Model

CL-EC100

EtherCAT communication specifications

Conforming standard

IEEE802.3u (100BASE-TX)*1

Communication speed

100 Mbps (100BASE-TX)*1

Communication period

Shortest 125 µs*1

Connection cable

STP/UTP cable, category 5e or above*1

Inter-node distance

100 m 328.1'*1

Communications port

RJ45 × 2*1

Supported functions

Process Data Object (PDO)
communication (Cyclic communication:
Process data communication)
Service Data Object (SDO) communication
(Non-cyclic communication: Mailbox
communication)
CoE
Distributed Clock
Explicit Device Identification*1

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

20% RH to 85% RH (no condensation)

Weight

Approx. 330 g

*1 Cannot be used when using EtherNet/IP™, PROFINET or PLC Link. • Cannot be used simultaneously with an encoder unit.

Keyence New Stock Image
Keyence LV-NH62 Keyence
Sale price €260,95
In stock, 11 units

Specifications

Model

LV-NH62

Type

Standard

FDA (CDRH) Part 1040.10

Class 1

IEC 60825-1

Light source

Visible semiconductor laser, Wavelength: 660 nm

Detecting
distance

MEGA

8 m 26.2'

ULTRA

7 m 23.0'

SUPER

6 m 19.7'

TURBO

5 m 16.4'

FINE

3.5 m 11.5'

HSP

2 m 6.6'

Environmental resistance

Ambient temperature

-10 to +55°C 14°F to 131°F (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Material

Case

Glass-reinforced plastic

Lens cover

Norbornene plastic

Reflective mirror

Polycarbonate, Acrylic

Weight

Approx. 65 g 2.29 oz

keyence Stock Image
Keyence OP-42323 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42323

Type

Single Light Guide for Coaxial Micro Lens

Overview

Single-type light guide for mounting optical fiber lighting.

Applicable product

CV-F10, CA-LMAx

keyence Stock Image
Keyence GL-RC20M Keyence
Sale price €338,95
Only 2 units left

Specifications

Model

GL-RC20M

Type

Extension Cable

Applicable product

GL-R Series

Number included

1 cable

Cable end

M14 connector (12-pin female) - Loose wires

Length

20 m 65.62'

Material

Connector for extension: PVC/nickel-plated brass, Cable: PVC

Note

Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension).
Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 910 g

Keyence Stock Image
Keyence GL-R06L Keyence
Sale price €577,95
Only 10 units left

Specifications

Model

GL-R06L

Detection capability

ø1.77" ø45 mm

Total length

9.45" 240mm

No. of beam

6

Detection height

7.87" 200mm

Protection height

11.22" 285mm

Beam axis spacing/Lens diameter

40 mm / ø5 1.57" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

6.6

OFF→ON

48.7*2

All blocked→ON

63.1*3

Optical synchronization system
(Channel A or B)

ON→OFF

6.9

OFF→ON

49.1*2

All blocked→ON

64.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

39

Receiver

67

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

320 g

Receiver

330 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence KV-X500 Keyence
Sale price €1.072,95
Only 5 units left

Specifications

Model

KV-X500

General specifications

Power voltage

System configuration using a KV-5000/3000 Series expansion unit: 24 VDC (±10%)
System configuration using only a KV‑8000/7000 Series expansion unit: 24 VDC (-15%/+20%)

Operating ambient temperature

System configuration using a KV-5000/3000 Series expansion unit: 0 to +50°C 32°F to +122°F (No freezing)
System configuration using only a KV‑8000/7000 Series expansion unit: 0 to +55°C 32°F to +131°F (No freezing)

Operating ambient humidity

System configuration using a KV-5000/3000 Series expansion unit: Up to 95% RH (No condensation)
System configuration using only a KV‑8000/7000 Series expansion unit: Up to 95% RH (No condensation)

Storage ambient temperature

System configuration using a KV-5000/3000 Series expansion unit: −20 to +70°C −4°F to +158°F
System configuration using only a KV‑8000/7000 Series expansion unit: −25 to +75°C −13°F to +167°F

Storage relative humidity

System configuration using a KV-5000/3000 Series expansion unit: Up to 95% RH (No condensation)
System configuration using only a KV‑8000/7000 Series expansion unit: Up to 95% RH (No condensation)

Operating environment

No dust or corrosive gas

Operating altitude

2,000 m 6561.7' or less

Noise immunity

IEC standard-compliant (IEC 61000-4-2/3/4/6)

Withstand voltage

1500 VAC, 1 minute (between the power supply terminal and the I/O terminals and between the external terminals and the case)

Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

Vibration resistance

Intermittent vibration

Frequency 5 to 9 Hz

Half amplitude: 3.5 mm 0.14" *1

Frequency 9 to 150 Hz

Acceleration: 9.8 m/s2 32.2 ft/s2 *1

Continuous vibration

Frequency 5 to 9 Hz

Half amplitude: 1.75 mm 0.07" *1

Frequency 9 to 150 Hz

Acceleration: 4.9 m/s2 16.1 ft/s2 *1

Internal current consumption

No more than 600 mA *2

Shock resistance

Acceleration: 150 m/s2 492.1 ft/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

Pollution degree

2

Weight

Approx. 410 g 14.47 oz
battery: Approx. 10 g 0.35 oz

Performance specifications

Processing speed

Contact I/O

Min. 0.50 ns

Double-precision floating point calculation

Min. 1.0 ns

Program

Size

128 MB

Max. count

4000

Material quantity

100000

Supported languages

Ladder, structured text, mnemonic

CPU memory capacity (project capacity + user memory capacity)

128 MB

Variables

Capacity

Overall

124 MB

Retained

3.5 MB

Max. count

Overall

200000

Retained

100000

Data type

BOOL, UINT, INT, UDINT, DINT, REAL, LREAL, TIME, STRING, ARRAY, structure, union, function block

Array

Maximum number of elements per dimension

1040187392

Maximum number of dimensions

8

Maximum occupiable data size per array

65011712 words

Specifiable data types

BOOL, UINT, INT, UDINT, DINT, REAL, LREAL, TIME, STRING, structure, union, function block

Specifiable subscripts

Devices, constants, variables, calculations *3 *4

Subscript-compatible data types

UINT, INT, UDINT, DINT

Structure/Union

Maximum number of definitions

8000

Maximum number of members per definition

2048

Maximum number of nested steps

8 *5

Specifiable data types

BOOL, UINT, INT, UDINT, DINT, REAL, LREAL, TIME, STRING, array, structure, union

Devices

Capacity

1.5 MB

Types

Input relay R

Total: 32,000 points, 1 bit (R00000 to R199915)

Output relay R

Internal auxiliary relay R

Link relay B

32,768 points, 1 bit (B0000 to B7FFF)

Internal auxiliary relay MR

64,000 points, 1 bit (MR000000 to MR399915)

Latch relay LR

16,000 points, 1 bit (LR00000 to LR99915)

Timer T

4,000 points, 32 bits (T0000 to T3999)

Counter C

4,000 points, 32 bits (C0000 to C3999)

Control memory CR

1,280 points, 1 bit (CR0000 to CR7915)

Data memory DM

65,535 points, 16 bits (DM00000 to DM65534)

Expansion data memory EM

65,535 points, 16 bits (EM00000 to EM65534)

File register FM

32,768 points, 16 bits (FM00000 to FM32767)

File register (dial mode) ZF

524,288 points, 16 bits (ZF000000 to ZF524287)

Link register W

32,768 points, 16 bits (W0000 to W7FFF)

Temporary memory TM

512 points, 16 bits (TM000 to TM511)

Index register Z

10 points, 32 bits (Z1 to Z10)

Control memory CM

7,600 points, 16 bits (CM0000 to CM7599)

Scan time setting

Fixed scan time operation

0.10 to 200.00 ms (units of 0.01 ms)

Fixed-period module

0.05 to 6000.00 ms (units of 0.01 ms), or 0.01 to 60.00 s (units of 0.01 s)

System

Maximum number of installable units

16 units (KV-8000/7000 Series expansion unit only)/48 units (KV-8000/7000 Series expansion unit, KV-5000/3000 Series expansion unit (when KV-EB1 is used))

CPU unit I/O points

Maximum number of I/O points

3072 points (64-point unit × 48)

Power failure hold function

Program memory

Flash ROM can be written 10000 times

Variables/Devices

Non-volatile RAM

Calendar timer

Backup capacitor lasts approx. 15 days (at 25°C 77°F) and approx. 5 years with KV-B1 (battery) (at 25°C 77°F)

Self-diagnosis function

CPU error, RAM error, and other problems

*1 Compliant with JIS B 3502 and IEC 61131-2, No. of sweeps: 10 times in each of the X, Y, and Z directions (for 100 minutes)
*2 The maximum current consumption is 3.4 A when using an expansion unit.
*3 Specify 0 or a positive integer for the subscript. A conversion or calculation error will occur if any other number is specified.
*4 Only structured text can use calculation expressions as subscripts. Calculation expressions cannot be used as subscripts in ladder programs.
*5 When writing stAAA.member, the number of nested rows will be 1. When writing stAAA.stBBB.member, the number of nested rows will be 2.

keyence Stock Image
Keyence GL-RP5NM Keyence
Sale price €332,95
Only 1 unit left

Specifications

Model

GL-RP5NM

Type

Unit connection cable

Number included

1 cable

Cable end

Main unit plug (Grey) - Loose wires

Length

5 m 16.40'

Material

Main unit connection connector: PBT, Cable: PVC

Note

Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 240 g

Keyence Stock Image
Keyence VH-Z20R Keyence
Sale price €2.696,95
Only 4 units left

Specifications

Model

VH-Z20R

Magnification

20 x, 30 x, 50 x, 100 x, 150 x, 200 x*1

Field-of-view

Horizontal

20 x: 15.24 mm 0.60"
30 x: 10.16 mm 0.40"
50 x: 6.10 mm 0.24"
100 x: 3.05 mm 0.12"
150 x: 2.03 mm 0.08"
200 x: 1.52 mm 0.06"

Vertical

20 x: 11.40 mm 0.45"
30 x: 7.60 mm 0.30"
50 x: 4.56 mm 0.18"
100 x: 2.28 mm 0.09"
150 x: 1.52 mm 0.06"
200 x: 1.14 mm 0.04"

Diagonal

20 x: 19.05 mm 0.75"
30 x: 12.70 mm 0.50"
50 x: 7.62 mm 0.30"
100 x: 3.81 mm 0.15"
150 x: 2.54 mm 0.10"
200 x: 1.91 mm 0.08"

Depth-of-field

20 x: 34 mm 1.34"
30 x: 15.5 mm 0.61"
50 x: 6.0 mm 0.24"
100 x: 1.6 mm 0.06"
150 x: 0.74 mm 0.03"
200 x: 0.44 mm 0.02"*2

Working distance

20 x, 30 x, 50 x, 100 x, 150 x, 200 x: 25.5 mm 1"

*1 Magnification on a 15-inch monitor.
*2 The value when the lens is set with priority to depth of field. The depth of field changes depending on the setting for the iris diaphragm ring.

Keyence Stock Image
Keyence FU-R77TZ Keyence
Sale price €132,95
Only 5 units left

Specifications

Model

FU-R77TZ*1

Type

Threaded and Hex-Shaped Active Receiver Fibers

Optical axis diameter

Transmitter: ø 1ø 0.04" Receiver: ø 3.2ø 0.13"

Size

M4

Fibre unit length

2 m6.6'Free-cut

Fibre unit diameter

ø 2.2ø 0.09"

Shape

Hex-shaped

Minimum bend radius

R2 mmR0.08"ToughFlex

Environmental resistance

Ambient temperature

−40 to +60 ˚C -40 to +140 °F

Weight

Approx. 25 g

*1 For details on the detecting distance, see the fiber amplifier catalog.

keyence Stock Image
Keyence SJ-E156A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E156A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1620 mm 63.78"*3

Total length

1520 mm 59.84"

No. ofelectrodes

25

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1700 g 59.97oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence OP-84349 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-84349

Type

Rear Fittings

Applicable product

LV-S62

Material

SUS304, SUS(Screw/nut)

Note

Screw (SUS) and nut (SUS) attached. Optional.

keyence Stock Image
Keyence FD-HCC0 Keyence
Sale price €298,95
Only 1 unit left

Specifications

Model

FD-HCC0

Cable end

M12, 8-pin female to M12, 4-pin male

Weight

Approx. 20 g

keyence Stock Image
Keyence WI-C10L Keyence
Sale price€0,00
Sold Out

Specifications

Model

WI-C10L

Type

Sensor head connecting cable, Standard

Cable end

L-shaped

Length

10 m 32.81'

keyence Stock Image
Keyence OP-88282 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88282

Length

10 m 32.8'

keyence Stock Image
Keyence OP-87033 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87033

Type

Transmitter-receiver cable

Length

1 m

Weight

Approx. 60 g 2.12 oz

keyence Stock Image
Keyence OP-88043 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88043

Length

2 m 6.56'

Note

This cable is used for connecting between sensor and PC or Ethernet switch.
When using IV Series as UL approved product, use Ethernet cable supporting NFPA79.

Keyence New Stock Image
Keyence BL-501 Keyence
Sale price €2.532,95
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence CA-H200MX Keyence
Sale price €1.913,95
In stock, 16 units

Specifications

Model

CA-H200MX

Image element

Monochrome CMOS, 16× high-speed reading using square-pixel

Unit cell size

3.45 µm × 3.45 µm 0.14 Mil × 0.14 Mil

Valid pixel count

1600 (H) × 1200 (V)

Image size

Equivalent to 1/2"

Scanning system

Progressive 11.7 ms

Pixel transfer frequency

195 MHz

Transfer system

Digital serial transfer

Electronic shutter

Can be set to 0.017 to 100 msec by specifying the following numerical inputs:
1/15, 1/30, 1/60, 1/120, 1/240, 1/500, 1/1000, 1/2000, 1/5000, 1/10000, 1/20000, 1/50000

Lens mount

C-mount

Environmental resistance

Ambient temperature

0 to 40°C 32 to 104°F

Relative humidity

85% RH or less

Weight

Approx. 280 g (not including lens)

Keyence New Stock Image
Keyence IG-010R Keyence
Sale price €1.735,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence N-400 Keyence
Sale price €530,95
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence KZ-300 Keyence
Sale price €962,95
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SI-F80RU Keyence
Sale price€0,00
Sold Out

Specifications

Model

SI-F80RU

Type

Wafer Thickness Measurement Type Spectrum Unit

Measurement range

10 to 310 µm 0.000394" to 0.0122" (when n=3.5)*1

Possible detection distance

80 to 81.1 mm 3.15" to 3.19"

Light source

Infrared SLD Output 0.6 mW, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part 1040.10*2)

Spot diameter

ø25 µm*3

Linearity

±0.1 µm ±0.000004" (when n=3.5)*4

Resolution

0.001 µm *5

Sampling cycle

200 µs

LED display

Target near center of measurement range : green lights. Target within measurement range : orange lights.
Target outside measurement range : flashes orange.

Temperature fluctuation

0.01% of F.S./°C

Environmental resistance

Enclosure rating

-

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +35 °C 32 to 95 °F

Relative humidity

35 to 80 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx. 1.2 kg

*1 Indicates the thickness measurement range when the refractive index is 3.5. (The thickness measurement range is 35 to 1100 µm0.001378" to 0.0433" when the refractive index is 1.)
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Indicates the minimum beam spot diameter within the measurement range.
*4 This value is obtained by measuring the gap between two glass plates with the number of averaging measurements set to 256, converted to a refractive index of 3.5.
*5 This value is obtained by measuring a 0.3 mm thick glass target within the possible detecting distance with the number of averaging measurements set to 4,096.