Specifications
Model |
ER-U12TPC *1 *2 |
|||
Type |
Ultra-long distance unshielded type Screw type M12 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *3 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
18 mm 0.71" ±10% *4 |
||
With distance switching (Mode 2) |
12 mm 0.47" ±10% *4 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *5 *6 |
||
With distance switching (Mode 2) |
50 Hz *5 *6 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *7 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
54 × 54 mm 2.13" × 2.13" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *10 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 35 g 1.24 oz |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

Specifications
Model |
ER-U18N |
|||
Type |
Ultra-long distance unshielded type Screw type M18 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
32 mm 1.26" ±10% *2 |
||
With distance switching (Mode 2) |
22 mm 0.87" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *3 *4 |
||
With distance switching (Mode 2) |
35 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
96 × 96 mm 3.78" × 3.78" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 110 g 3.88 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
ER-U18P |
|||
Type |
Ultra-long distance unshielded type Screw type M18 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
32 mm 1.26" ±10% *2 |
||
With distance switching (Mode 2) |
22 mm 0.87" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *3 *4 |
||
With distance switching (Mode 2) |
35 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
96 × 96 mm 3.78" × 3.78" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 110 g 3.88 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
ER-U18PC *1 |
|||
Type |
Ultra-long distance unshielded type Screw type M18 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *2 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
32 mm 1.26" ±10% *3 |
||
With distance switching (Mode 2) |
22 mm 0.87" ±10% *3 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *4 *5 |
||
With distance switching (Mode 2) |
35 Hz *4 *5 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *6 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
96 × 96 mm 3.78" × 3.78" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) *8 |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *9 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g 2.29 oz |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

Specifications
Model |
ER-U30N |
|||
Type |
Ultra-long distance unshielded type Screw type M30 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
52 mm 2.05" ±10% *2 |
||
With distance switching (Mode 2) |
32 mm 1.26" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *3 *4 |
||
With distance switching (Mode 2) |
20 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
156 × 156 mm 6.14" × 6.14" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 190 g 6.71 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
ER-U30P |
|||
Type |
Ultra-long distance unshielded type Screw type M30 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
52 mm 2.05" ±10% *2 |
||
With distance switching (Mode 2) |
32 mm 1.26" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *3 *4 |
||
With distance switching (Mode 2) |
20 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
156 × 156 mm 6.14" × 6.14" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 190 g 6.71 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
ER-U30PC *1 |
|||
Type |
Ultra-long distance unshielded type Screw type M30 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *2 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
52 mm 2.05" ±10% *3 |
||
With distance switching (Mode 2) |
32 mm 1.26" ±10% *3 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *4 *5 |
||
With distance switching (Mode 2) |
20 Hz *4 *5 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *6 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
156 × 156 mm 6.14" × 6.14" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) *8 |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *9 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 150 g 5.30 oz |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

Specifications
Model |
ES-11AC*1 |
|||
Type |
AC |
|||
Operation mode |
N.O. |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
Thyristor 240 VAC, 5 to 300 mA |
||
Disconnection alarm output |
― |
|||
Leakage current (OFF time) |
0.2 mA max. |
|||
Response time |
10 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
85 to 240 VAC 50/60 Hz |
||
Current/power consumption |
1 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 125 g |
|||
*1 This product does not comply with the EMC directive. | ||||

Specifications
Model |
ES-12AC*1 |
|||
Type |
AC |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
Thyristor 115 VAC, |
||
Disconnection alarm output |
― |
|||
Leakage current (OFF time) |
0.2 mA max. |
|||
Response time |
10 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
85 to 115 VAC 50/60 Hz |
||
Current/power consumption |
1.5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 82 g |
|||
*1 This product does not comply with the EMC directive. | ||||


Specifications
Model |
ES-21AC*1 |
|||
Type |
AC |
|||
Operation mode |
N.C. |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
Thyristor 240 VAC, 5 to 300 mA |
||
Disconnection alarm output |
― |
|||
Leakage current (OFF time) |
0.2 mA max. |
|||
Response time |
10 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
85 to 240 VAC 50/60 Hz |
||
Current/power consumption |
1 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 125 g |
|||
*1 This product does not comply with the EMC directive. | ||||

Specifications
Model |
ES-32DC |
|||
Type |
DC |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
NPN: 200 mA (40 V) max. |
||
Disconnection alarm output |
NPN: 100 mA (40 V) max. Residual voltage: 1 V max. |
|||
Leakage current (OFF time) |
― |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
10 to 28 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
18 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 48 g |
|||

Specifications
Model |
ES-M1*1 |
|||
Type |
One-line expansion system |
|||
Shape |
Main unit |
|||
Operation mode |
N.O./N.C. switch-selectable |
|||
Timer function |
10-ms delay / timer OFF switchable*2 |
|||
Output |
NPN |
|||
Output |
Control output |
NPN open collector 100 mA max. 40 V, residual voltage 1 V max. |
||
Disconnection alarm output |
NPN open collector 100 mA max. |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
Within ±8% of detecting distance at +23°C 73.4°F when within 0 to 50°C 32 to 122°F temperature range |
|||
Sensitivity adjustment |
25-turn trimmer |
|||
Protection circuit |
Reverse power connection protection, output overcurrent protection, output surge protection |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 65 g (including nuts and 2-m 9.8' cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. | ||||

Specifications
Model |
ES-M1P*1 |
|||
Type |
One-line expansion system |
|||
Shape |
Main unit |
|||
Operation mode |
N.O./N.C. switch-selectable |
|||
Timer function |
10-ms delay / timer OFF switchable*2 |
|||
Output |
PNP |
|||
Output |
Control output |
PNPopen collector 100 mA max. 26.4 V, residual voltage 1 V max. |
||
Disconnection alarm output |
PNPopen collector 100 mA max. |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
Within ±8% of detecting distance at +23°C 73.4°F when within 0 to 50°C 32 to 122°F temperature range |
|||
Sensitivity adjustment |
25-turn trimmer |
|||
Protection circuit |
Reverse power connection protection, output overcurrent protection, output surge protection |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 65 g (including nuts and 2-m 9.8' cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. | ||||

Specifications
Model |
ES-M2*1 |
|||
Type |
One-line expansion system |
|||
Shape |
Expansionunit |
|||
Operation mode |
N.O./N.C. switch-selectable |
|||
Timer function |
10-ms delay / timer OFF switchable*2 |
|||
Output |
NPN |
|||
Output |
Control output |
NPN open collector 100 mA max. 40 V, residual voltage 1 V max. |
||
Disconnection alarm output |
―*3 |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
Within ±8% of detecting distance at +23°C 73.4°F when within 0 to 50°C 32 to 122°F temperature range |
|||
Sensitivity adjustment |
25-turn trimmer |
|||
Protection circuit |
Reverse power connection protection, output overcurrent protection, output surge protection |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 35 g (including nuts and 2-m 9.8' cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. | ||||

Specifications
Model |
ES-M2P*1 |
|||
Type |
One-line expansion system |
|||
Shape |
Expansionunit |
|||
Operation mode |
N.O./N.C. switch-selectable |
|||
Timer function |
10-ms delay / timer OFF switchable*2 |
|||
Output |
PNP |
|||
Output |
Control output |
PNPopen collector 100 mA max. 26.4 V, residual voltage 1 V max. |
||
Disconnection alarm output |
―*3 |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
Within ±8% of detecting distance at +23°C 73.4°F when within 0 to 50°C 32 to 122°F temperature range |
|||
Sensitivity adjustment |
25-turn trimmer |
|||
Protection circuit |
Reverse power connection protection, output overcurrent protection, output surge protection |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 35 g (including nuts and 2-m 9.8' cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. | ||||

Specifications
Model |
ES-X38 |
|||
Type |
DC |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
NPN: 100 mA (40 V) max. |
||
Disconnection alarm output |
NPN: 100 mA (40 V) max. Residual voltage: 1 V max. |
|||
Leakage current (OFF time) |
― |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 67 g (including 2-m 6.6' cable) |
|||

Specifications
Model |
ET-110 |
|||
Type |
Sensor Head, Shielded Type |
|||
Shape |
Threaded |
|||
Detecting distance |
0 to 2.0 mm 0.08" |
|||
Detectable object |
Nonferrous metals |
|||
Standard target (aluminum, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Response frequency |
300 Hz |
|||
Hysteresis adjustment |
1-turn trimmer (240°), approx. 2 to 10% of detecting distance (variable) |
|||
Operation mode |
15-turn trimmer |
|||
Temperature characteristics |
+25 to -15% max. of detecting distance at 23°C 73.4°F, |
|||
Output |
Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. |
||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current consumption |
45 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
nut: 2 |
|||
Weight |
Approx. 58 g (including 3m cable) |
|||

Specifications
Model |
ET-305 |
|||
Type |
Sensor Head, Shielded Type |
|||
Shape |
Cylindrical |
|||
Detecting distance |
0 to 1.0 mm 0.04" |
|||
Detectable object |
Nonferrous metals |
|||
Standard target (aluminum, t=1 mm 0.04") |
5 x 5 mm 0.20" |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Response frequency |
1 kHz |
|||
Hysteresis adjustment |
1-turn trimmer (240°), approx. 2 to 10% of detecting distance (variable) |
|||
Operation mode |
15-turn trimmer |
|||
Temperature characteristics |
+25 to -15% max. of detecting distance at 23°C 73.4°F, |
|||
Output |
Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. |
||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current consumption |
45 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
― |
|||
Weight |
Approx. 50 g (including 3m cable) |
|||

Specifications
Model |
ET-308 |
|||
Type |
Sensor Head, Shielded Type |
|||
Shape |
Cylindrical |
|||
Detecting distance |
0 to 2.0 mm 0.08" |
|||
Detectable object |
Nonferrous metals |
|||
Standard target (aluminum, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Response frequency |
400 Hz |
|||
Hysteresis adjustment |
1-turn trimmer (240°), approx. 2 to 10% of detecting distance (variable) |
|||
Operation mode |
15-turn trimmer |
|||
Temperature characteristics |
+25 to -15% max. of detecting distance at 23°C 73.4°F, |
|||
Output |
Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. |
||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current consumption |
45 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
― |
|||
Weight |
Approx. 52 g (including 3m cable) |
|||

Specifications
Model |
ET-90 |
|||
Type |
Shielded |
|||
Detectable object |
Nonferrous metals |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Hysteresis adjustment |
1-turn trimmer (240°), approx. 2 to 10% of detecting distance (variable) |
|||
Operation mode |
N.O./N.C. (switch-selectable) |
|||
Temperature characteristics |
+25 to -15% max. of detecting distance at 23°C 73.4°F, |
|||
Output |
Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. |
||
Control output |
Disconnection alarm output |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Indicator lamp |
Output: Red LED, Stable operation: Green LED |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current consumption |
45 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
Dedicated mounting bracket, plastic screwdriver |
|||
Weight |
Approx. 80 g (including 2m cable) |
|||

Specifications
Model |
EV-108M |
|||
Type |
Shielded |
|||
Shape |
M8 |
|||
Detecting distance |
1.5 mm 0.06" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
800 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity,surge voltage |
|||
Cable length |
2 m 6.6' |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Stainless steel (SUS304) |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 42 g |
|||

Specifications
Model |
EV-108MC |
|||
Type |
DC , Shielded |
|||
Shape |
M8 |
|||
Detecting distance |
1.5 mm 0.06" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis | ||||
Response frequency |
800 Hz |
|||
Operation mode |
N.C. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity,surge voltage |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Stainless steel (SUS304) |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 42 g |
|||

Specifications
Model |
EV-108MSO (2091) |
|||
Type |
Shielded |
|||
Shape |
M8 |
|||
Detecting distance |
1.5 mm 0.06" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
800 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity, surge voltage |
|||
Cable length |
500 mm19.685" |
|||
Rating |
Power voltage |
12 to 24 VDC |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Case material |
Stainless steel (SUS304) |
|||
Weight |
Approx. 30 g |
|||