keyence Stock Image
Keyence ER-M18FP Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-M18FP

Type

Compact all-metal shielded type Thin type t = 8 mm Cable PNP output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

N.O.

Button

None

Button

Function

Detecting distance

10 mm 0.39" ±10% *2

Response frequency

50 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

30 × 30 mm 1.18" × 1.18"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less, Max. 50 mA

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1010 mW or less
(43 mA or less at 24 V,
64 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing)

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Material

Head

SUS316L, PBT
Epoxy resin

Amplifier

Header-to-amplifier cable: TPU, Case: PBT/TPU
[Connector] Indicator: LCP, Connector metal: SUS303, Connector: LCP
[Cable] Indicator: TPU, Power cable: PVC

Accessories

Accessories

Weight

Approx. 125 g
4.41 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.

keyence Stock Image
Keyence ER-M18FPC Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-M18FPC *1

Type

Compact all-metal shielded type Thin type t = 8 mm Connector (M8 3-pin) PNP output

Power supply cable length

*2

No. of control outputs

1

Output mode

N.O.

Button

None

Button

Function

Detecting distance

10 mm 0.39" ±10% *3

Response frequency

50 Hz *4 *5

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *6

Standard detectable object (Iron, t = 1 mm 0.04")

30 × 30 mm 1.18" × 1.18"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less, Max. 50 mA

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *7

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1010 mW or less
(43 mA or less at 24 V,
64 mA or less at 16 V) *8

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing)

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Material

Head

SUS316L, PBT
Epoxy resin

Amplifier

Header-to-amplifier cable: TPU, Case: PBT/TPU
[Connector] Indicator: LCP, Connector metal: SUS303, Connector: LCP
[Cable] Indicator: TPU, Power cable: PVC

Accessories

Accessories

Weight

Approx. 80 g
2.82 oz

*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps).
*2 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*3 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*4 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*5 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*6 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*7 Residual voltage is for when a 2 m 6.6' cable is used.
*8 For IO-Link compatible models under *1, power consumption is as follows.
ø4.5, M5 type: 1050 mW or less (44 mA or less at 24 V, 66 mA or less at 16 V),
M8 L type, thin type t = 4.7 mm: 1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V),
thin type t = 8 mm: 1090 mW or less (46 mA or less at 24 V, 69 mA or less at 16 V)

keyence Stock Image
Keyence ER-N10 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-N10

Type

Separate amplifier Amplifier unit Expansion unit (zero line type)

No. of control outputs

None *1

No. of external inputs

Temperature characteristics

±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *2

Response time

150 μs *3/ 300 μs *3/ 1 ms / 4 ms / 16 ms / 64 ms (switchable)

Network compatibility

NU Series

Function

Operation mode

Normal / Magnetic metal / Non-magnetic metal / Hybrid

Timer function

Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot

I/O

Control output

Open-collector, 30 VDC or less, PNP/NPN switchable
When used as a solitary unit: 100 mA or less for 1 output; 100 mA or less in total for 2 outputs / When used as an expansion unit: 50 mA or less in total for 2 outputs
Residual voltage: 1.7 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA)

External input

Tuning / Detection stop / Zero shift / Hold value reset (switchable)
Short-circuit current: 1.5 mA or less; Input time: 3 ms or more ON, 20 ms or more OFF (When tuning is selected: 25 ms or more ON, 25 ms or more OFF)

Additional expansion units

Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

No. of mutual interference prevention units

OFF / 4 units / 8 units (selectable) *4

Power supply

Power voltage

18 to 30 VDC *5 (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

830 mW or less
(35 mA or less at 24 V, 47 mA or less at 18 V)

Environmental resistance

Ambient temperature

Operation: -25 to +55°C -13°F to +131°F *6, Storage: -30 to 70°C -22°F to +158°F (no freezing)

Relative humidity

Operation/storage: Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Case material

Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass

Accessories

Instruction manual

Weight

Approx. 50 g 1.77 oz

*1 Counts as 1 output when connecting multiple units to the FS-MC8P/MC8N or NU Series.
*2 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range.
*3 150 μs and 300 μs are selectable only when the operation mode is set to “Normal”.
*4 The response time changes as follows when 4 or 8 units are selected as the number of interference prevention units. When set to 4 units: 5 ms / 10 ms / 40 ms / 170 ms / 700 ms (switchable), When set to 8 units: 10 ms / 20 ms / 70 ms / 300 ms / 1.2 s (switchable)
*5 Use a power voltage of 20 V or more when connecting 4 or more expansion units.
*6 When 1 or 2 units are added: -25 to +55°C -13°F to +131°F; when 3 to 10 units are added: -25 to +50°C -13°F to +122°F; when 11 to 16 units are added: -25 to +45°C -13°F to +113°F. When using two outputs, one unit is counted as two units. The prescribed values for the operating ambient temperature assume the sensor amplifier is mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence ER-N11 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-N11

Type

Separate amplifier Amplifier unit Main unit (cable type)

No. of control outputs

2

No. of external inputs

1

Temperature characteristics

±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *1

Response time

150 μs *2/ 300 μs *2/ 1 ms / 4 ms / 16 ms / 64 ms (switchable)

Network compatibility

Function

Operation mode

Normal / Magnetic metal / Non-magnetic metal / Hybrid

Timer function

Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot

I/O

Control output

Open-collector, 30 VDC or less, PNP/NPN switchable
When used as a solitary unit: 100 mA or less for 1 output; 100 mA or less in total for 2 outputs / When used as an expansion unit: 50 mA or less in total for 2 outputs
Residual voltage: 1.7 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA)

External input

Tuning / Detection stop / Zero shift / Hold value reset (switchable)
Short-circuit current: 1.5 mA or less; Input time: 3 ms or more ON, 20 ms or more OFF (When tuning is selected: 25 ms or more ON, 25 ms or more OFF)

Additional expansion units

Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

No. of mutual interference prevention units

OFF / 4 units / 8 units (selectable) *3

Power supply

Power voltage

18 to 30 VDC *4 (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V)

Environmental resistance

Ambient temperature

Operation: -25 to +55°C -13°F to +131°F *5, Storage: -30 to 70°C -22°F to +158°F (no freezing)

Relative humidity

Operation/storage: Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Case material

Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass

Accessories

Instruction manual

Weight

Approx. 90 g 3.18 oz

*1 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range.
*2 150 μs and 300 μs are selectable only when the operation mode is set to “Normal”.
*3 The response time changes as follows when 4 or 8 units are selected as the number of interference prevention units. When set to 4 units: 5 ms / 10 ms / 40 ms / 170 ms / 700 ms (switchable), When set to 8 units: 10 ms / 20 ms / 70 ms / 300 ms / 1.2 s (switchable)
*4 Use a power voltage of 20 V or more when connecting 4 or more expansion units.
*5 When 1 or 2 units are added: -25 to +55°C -13°F to +131°F; when 3 to 10 units are added: -25 to +50°C -13°F to +122°F; when 11 to 16 units are added: -25 to +45°C -13°F to +113°F. When using two outputs, one unit is counted as two units. The prescribed values for the operating ambient temperature assume the sensor amplifier is mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence ER-N11C Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-N11C *1

Type

Separate amplifier Amplifier unit Main unit (expansion not supported) (M8 connector type) *2

No. of control outputs

2 *3

No. of external inputs

1 *3

Temperature characteristics

±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *4

Response time

150 μs *5/ 300 μs *5/ 1 ms / 4 ms / 16 ms / 64 ms (switchable)

Network compatibility

IO-Link (Specification v1.1/COM2 (38.4 kbps))

Function

Operation mode

Normal / Magnetic metal / Non-magnetic metal / Hybrid

Timer function

Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot

I/O

Control output

Open-collector, 30 VDC or less, PNP/NPN switchable
When used as a solitary unit: 100 mA or less for 1 output; 100 mA or less in total for 2 outputs / When used as an expansion unit: 50 mA or less in total for 2 outputs
Residual voltage: 1.7 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA)

External input

Tuning / Detection stop / Zero shift / Hold value reset (switchable)
Short-circuit current: 1.5 mA or less; Input time: 3 ms or more ON, 20 ms or more OFF (When tuning is selected: 25 ms or more ON, 25 ms or more OFF)

Additional expansion units

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

No. of mutual interference prevention units

Power supply

Power voltage

18 to 30 VDC *6 (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V)

Environmental resistance

Ambient temperature

Operation: -25 to +55°C -13°F to +131°F *7, Storage: -30 to 70°C -22°F to +158°F (no freezing)

Relative humidity

Operation/storage: Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Case material

Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass

Accessories

Instruction manual

Weight

Approx. 55 g 1.94 oz

*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps).
*2 Ensure the power cable is no longer than 30 m 98.4' for M8 connector types and no longer than 20 m 65.6' with IO-Link connections.
*3 Output 2 and the external input are selectable.
*4 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range.
*5 150 μs and 300 μs are selectable only when the operation mode is set to “Normal”.
*6 Use a power voltage of 20 V or more when connecting 4 or more expansion units.
*7 When 1 or 2 units are added: -25 to +55°C -13°F to +131°F; when 3 to 10 units are added: -25 to +50°C -13°F to +122°F; when 11 to 16 units are added: -25 to +45°C -13°F to +113°F. When using two outputs, one unit is counted as two units. The prescribed values for the operating ambient temperature assume the sensor amplifier is mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence ER-N12 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-N12

Type

Separate amplifier Amplifier unit Expansion unit (cable type)

No. of control outputs

2

No. of external inputs

1

Temperature characteristics

±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *1

Response time

150 μs *2/ 300 μs *2/ 1 ms / 4 ms / 16 ms / 64 ms (switchable)

Network compatibility

NU Series

Function

Operation mode

Normal / Magnetic metal / Non-magnetic metal / Hybrid

Timer function

Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot

I/O

Control output

Open-collector, 30 VDC or less, PNP/NPN switchable
When used as a solitary unit: 100 mA or less for 1 output; 100 mA or less in total for 2 outputs / When used as an expansion unit: 50 mA or less in total for 2 outputs
Residual voltage: 1.7 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA)

External input

Tuning / Detection stop / Zero shift / Hold value reset (switchable)
Short-circuit current: 1.5 mA or less; Input time: 3 ms or more ON, 20 ms or more OFF (When tuning is selected: 25 ms or more ON, 25 ms or more OFF)

Additional expansion units

Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

No. of mutual interference prevention units

OFF / 4 units / 8 units (selectable) *3

Power supply

Power voltage

18 to 30 VDC *4 (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V)

Environmental resistance

Ambient temperature

Operation: -25 to +55°C -13°F to +131°F *5, Storage: -30 to 70°C -22°F to +158°F (no freezing)

Relative humidity

Operation/storage: Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Case material

Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass

Accessories

Instruction manual

Weight

Approx. 90 g 3.18 oz

*1 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range.
*2 150 μs and 300 μs are selectable only when the operation mode is set to “Normal”.
*3 The response time changes as follows when 4 or 8 units are selected as the number of interference prevention units. When set to 4 units: 5 ms / 10 ms / 40 ms / 170 ms / 700 ms (switchable), When set to 8 units: 10 ms / 20 ms / 70 ms / 300 ms / 1.2 s (switchable)
*4 Use a power voltage of 20 V or more when connecting 4 or more expansion units.
*5 When 1 or 2 units are added: -25 to +55°C -13°F to +131°F; when 3 to 10 units are added: -25 to +50°C -13°F to +122°F; when 11 to 16 units are added: -25 to +45°C -13°F to +113°F. When using two outputs, one unit is counted as two units. The prescribed values for the operating ambient temperature assume the sensor amplifier is mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence ER-NH028 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH028

Cable

Standard

Stable detection range

0 to 0.6 mm
0 to 0.02" *1 *2

Maximum operating distance

1.2 mm 0.05" *1 *3

Hysteresis distance

Adjustable

Repeatability

1 μm 0.04 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

5 × 5 mm 0.20" × 0.20"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Epoxy resin

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 30 g
1.06 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH028U Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH028U

Cable

Standard

Stable detection range

0 to 3 mm
0 to 0.12" *1 *2

Maximum operating distance

7 mm 0.28" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

10 × 10 mm
0.39" × 0.39"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Ceramic

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 35 g
1.24 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH035F Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH035F

Cable

Standard

Stable detection range

0 to 1 mm
0 to 0.04" *1 *2

Maximum operating distance

3 mm 0.12" *1 *3

Hysteresis distance

Adjustable

Repeatability

1 μm 0.04 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

5 × 5 mm
0.20" × 0.20"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Epoxy resin

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

M2 screw/nut/spring washer/
flat washer: Iron nickel plating

Accessories

M2 screw/nut/
spring washer/
flat washer ×2 each

Weight

Approx. 40 g
1.41 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH038 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH038

Cable

Standard

Stable detection range

0 to 0.8 mm
0 to 0.03" *1 *2

Maximum operating distance

2 mm 0.08" *1 *3

Hysteresis distance

Adjustable

Repeatability

1 μm 0.04 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

5 × 5 mm 0.20" × 0.20"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Epoxy resin

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 40 g
1.41 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH048F Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH048F

Cable

Standard

Stable detection range

0 to 5 mm
0 to 0.20" *1 *2

Maximum operating distance

8 mm 0.31" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

15 × 15 mm
0.59" × 0.59"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Epoxy resin

Case

SUS303

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 65 g
2.29 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH054 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH054

Cable

Standard

Stable detection range

0 to 1 mm 0 to 0.04" *1 *2

Maximum operating distance

3 mm 0.12" *1 *3

Hysteresis distance

Adjustable

Repeatability

1 μm 0.04 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

5 × 5 mm 0.20" × 0.20"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

PVC

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 60 g
2.12 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH054G Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH054G

Cable

Stainless steel
spiral tube

Stable detection range

0 to 1 mm 0 to 0.04" *1 *2

Maximum operating distance

3 mm 0.12" *1 *3

Hysteresis distance

Adjustable

Repeatability

1 μm 0.04 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

5 × 5 mm 0.20" × 0.20"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

PVC

Case

SUS304

Cable

Cable: PVC
Tube: SUS304

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 85 g
3.00 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH080 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH080

Cable

Standard

Stable detection range

0 to 2 mm 0 to 0.08" *1 *2

Maximum operating distance

5 mm 0.20" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

10 × 10 mm 0.39" × 0.39"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Phenol resin

Case

SUS304

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 60 g
2.12 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH080G Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH080G

Cable

Stainless steel
spiral tube

Stable detection range

0 to 2 mm 0 to 0.08" *1 *2

Maximum operating distance

5 mm 0.20" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

10 × 10 mm 0.39" × 0.39"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Phenol resin

Case

SUS304

Cable

Cable: PVC
Tube: SUS304
End cap: Nickel-plated brass

Sensor head connector

PA66, polycarbonate

Accessories

Accessories

Weight

Approx. 90 g
3.18 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH100 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH100

Cable

Standard

Stable detection range

0 to 2 mm 0 to 0.08" *1 *2

Maximum operating distance

5 mm 0.20" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

10 × 10 mm 0.39" × 0.39"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Phenol resin

Case

Chrome-plated
brass

Cable

PVC

Sensor head connector

PA66, polycarbonate

Accessories

Nut: Chrome-plated brass

Accessories

M10 nut × 2

Weight

Approx. 65 g
2.29 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-NH100G Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-NH100G

Cable

Stainless steel
spiral tube

Stable detection range

0 to 2 mm 0 to 0.08" *1 *2

Maximum operating distance

5 mm 0.20" *1 *3

Hysteresis distance

Adjustable

Repeatability

2 μm 0.08 Mil *1 *4

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

10 × 10 mm 0.39" × 0.39"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F)
±15% or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
(For ER-NH028/038/035F/028U) -10 to +15 % or less of detecting distance at +25°C+77°F (0 to +50°C 32°F to 122°F),
-15 to +20 % or less of detecting distance at +25°C +77°F (-10 to 0°C 14°F to 32°F, +50 to +60°C 122°F to 140°F)
*1 *6

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-10 to +60°C 14°F to 140°F (no freezing)

Relative humidity

Up to 85% RH (No condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detection surface

Phenol resin

Case

Chrome-plated
brass

Cable

Cable: PVC
Tube: SUS304
End cap: Nickel-plated brass

Sensor head connector

PA66, polycarbonate

Accessories

Nut: Chrome-plated brass

Accessories

M10 nut × 2

Weight

Approx. 100 g
3.53 oz

*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object.
*2 The range where 2-point adjustment is normally possible with a detectable object placed within this range and with no detectable object. The stable detection range becomes narrower when in magnetic metal / non-magnetic metal mode.
*3 The maximum distance of the stable detection range and the distance that can be detected under constant temperature when 2-point adjustment is used with no detectable object and the set value is set appropriately.
*4 Values obtained by converting the fluctuation range of the detection amount to the detecting distance under a constant environment using KEYENCE default settings.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 The value when using the 2-point adjustment function at a distance of 25% of the stable detection range with no detectable object and a standard detectable object at a distance of 50% of the stable detection range.

keyence Stock Image
Keyence ER-U08N Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U08N

Type

Ultra-long distance unshielded type Screw type M8 Cable NPN output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

9 mm 0.35" ±10% *2

With distance switching (Mode 2)

6 mm 0.24" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

45 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

27 × 27 mm 1.06" × 1.06"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

NPN output: 0.9 V or less (Output current: 10 mA or less) /
1.4 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 65 g 2.29 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U08P Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U08P

Type

Ultra-long distance unshielded type Screw type M8 Cable PNP output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

9 mm 0.35" ±10% *2

With distance switching (Mode 2)

6 mm 0.24" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

45 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

27 × 27 mm 1.06" × 1.06"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 65 g 2.29 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U08PC Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U08PC

Type

Ultra-long distance unshielded type Screw type M8 Connector (M8 3-pin) PNP output

Power supply cable length

*1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

9 mm 0.35" ±10% *2

With distance switching (Mode 2)

6 mm 0.24" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

45 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

27 × 27 mm 1.06" × 1.06"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 20 g 0.71 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U08TPC Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U08TPC *1 *2

Type

Ultra-long distance unshielded type Screw type M8 Connector (M8 3-pin) PNP output

Power supply cable length

*3

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

9 mm 0.35" ±10% *4

With distance switching (Mode 2)

6 mm 0.24" ±10% *4

Response frequency

With default settings (Mode 1)

15 Hz *5 *6

With distance switching (Mode 2)

45 Hz *5 *6

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *7

Standard detectable object (Iron, t = 1 mm 0.04")

27 × 27 mm 1.06" × 1.06"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *8

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V) *9

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *10

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 20 g 0.71 oz

*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps).
*2 Long-body type. See “Dimensions” for details.
*3 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*4 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*5 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*6 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*7 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*8 Residual voltage is for when a 2 m 6.6' cable is used.
*9 For IO-Link-compatible devices listed under *1, power consumption is as follows.
M8 type: 840 mW or less (35 mA or less at 24 V, 53 mA or less at 16 V)
M12 type: 1090 mW or less (46 mA or less at 24 V, 69 mA or less at 16 V)
M18, M30 type: 1250 mW or less (53 mA or less at 24 V, 79 mA or less at 16 V)
*10 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U12N Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U12N

Type

Ultra-long distance unshielded type Screw type M12 Cable NPN output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

18 mm 0.71" ±10% *2

With distance switching (Mode 2)

12 mm 0.47" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

50 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

54 × 54 mm 2.13" × 2.13"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

NPN output: 0.9 V or less (Output current: 10 mA or less) /
1.4 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1000 mW or less
(42 mA or less at 24 V, 63 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 75 g 2.65 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U12P Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U12P

Type

Ultra-long distance unshielded type Screw type M12 Cable PNP output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

18 mm 0.71" ±10% *2

With distance switching (Mode 2)

12 mm 0.47" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

50 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

54 × 54 mm 2.13" × 2.13"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1000 mW or less
(42 mA or less at 24 V, 63 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 75 g 2.65 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence ER-U12PC Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-U12PC

Type

Ultra-long distance unshielded type Screw type M12 Connector (M12 4-pin) PNP output

Power supply cable length

*1

No. of control outputs

2

Output mode

Output 1

N.O.

Output 2

N.C.

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

18 mm 0.71" ±10% *2

With distance switching (Mode 2)

12 mm 0.47" ±10% *2

Response frequency

With default settings (Mode 1)

15 Hz *3 *4

With distance switching (Mode 2)

50 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

54 × 54 mm 2.13" × 2.13"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1000 mW or less
(42 mA or less at 24 V, 63 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 35 g 1.24 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

Recently viewed