abb

16438 products

Showing 1057 - 1080 of 16438 products

Showing 1057 - 1080 of 16438 products
View
1SBL371001R8000 ABB - A63-30-00 220-230V 50Hz / 230-240V 60Hz

A63-30-00 220-230V 50Hz / 230-240V 60Hz Contactor

1SBL371001R8011 ABB - A63-30-11 220-230V 50Hz / 230-240V 60Hz

A63-30-11 220-230V 50Hz / 230-240V 60Hz Contactor. A63 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting.

1SBL371001R8411 ABB - A63-30-11 110V 50Hz / 110-120V 60Hz
ABB 1SBL371001R8411 ABB - A63-30-11 110V 50Hz / 110-120V 60Hz
Sale price €991,95
Only 4 units left

A63-30-11 110V 50Hz / 110-120V 60Hz Contactor

1SBL371001R8611 ABB - A63-30-11 400-415V 50Hz / 415-440V 60Hz

A63-30-11 400-415V 50Hz / 415-440V 60Hz Contactor

1SBL371001R8800 ABB - A63-30-00 230-240V 50Hz / 240-260V 60Hz

A63-30-00 230-240V 50Hz / 240-260V 60Hz Contactor

1SBL371001R8822 ABB - A63-30-22 230-240V 50Hz / 240-260V 60Hz

A63-30-22 230-240V 50Hz / 240-260V 60Hz Contactor

1SBL371022R8000 ABB - UA63-30-00 220-230V 50Hz / 230-240V 60Hz

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
108 mm
Product Net Height:
110 mm
Product Net Weight:
1.16 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 21 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 45 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 37 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 43 kvar
(440 V) 40 °C, 50 / 60 Hz 50 kvar
(440 V) 55 °C, 50 / 60 Hz 48 kvar
(440 V) 70 °C, 50 / 60 Hz 41 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 50 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 50 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 45 kvar
(690 V) 40 °C, 50 / 60 Hz 70 kvar
(690 V) 55 °C, 50 / 60 Hz 70 kvar
(690 V) 70 °C, 50 / 60 Hz 60 kvar
(230 / 240 V) 40 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 25 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 21 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 45 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 37 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 43 kvar
(440 V) 40 °C, 50 / 60 Hz 50 kvar
(440 V) 55 °C, 50 / 60 Hz 48 kvar
(440 V) 70 °C, 50 / 60 Hz 41 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 50 kvar
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Average Pull-in Value 60 Hz 180 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
Average Holding Value 50 / 60 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Average Pull-in Value 60 Hz 180 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Flexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Environmental

Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GOST Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
140 mm
Package Level 1 Depth / Length:
146 mm
Package Level 1 Height:
96 mm
Package Level 1 Gross Weight:
1.16 kg
Package Level 1 EAN:
3471522090805

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001079 - Capacitor contactor
ETIM 8:
EC001079 - Capacitor contactor
ETIM 9:
EC001079 - Capacitor contactor
eClass:
V11.0 : 27371006
UNSPSC:
39121529
1SBL371024R8400 ABB - UA63-30-00RA 110V 50Hz / 110-120V 60Hz

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
140.4 mm
Product Net Height:
150 mm
Product Net Weight:
1.35 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 27 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 23 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 50 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 45 kvar
(440 V) 40 °C, 50 / 60 Hz 55 kvar
(440 V) 55 °C, 50 / 60 Hz 48 kvar
(440 V) 70 °C, 50 / 60 Hz 42.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 65 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 60 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 50 kvar
(690 V) 40 °C, 50 / 60 Hz 80 kvar
(690 V) 55 °C, 50 / 60 Hz 75 kvar
(690 V) 70 °C, 50 / 60 Hz 65 kvar
(230 / 240 V) 40 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 27 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 23 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 50 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 45 kvar
(440 V) 40 °C, 50 / 60 Hz 55 kvar
(440 V) 55 °C, 50 / 60 Hz 48 kvar
(440 V) 70 °C, 50 / 60 Hz 42.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 65 kvar
Short-Circuit Protective Devices:
gG Type Fuses 200 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Electrical Durability:
Ue =< 440 V 250000 cycle
Ue = 500 ... 690 V 100000 cycle
Ue =< 440 V 250000 cycle
Ue = 500 ... 690 V 100000 cycle
Maximum Electrical Switching Frequency:
240 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 110 V
60 Hz 110 ... 120 V
50 Hz 110 V
60 Hz 110 ... 120 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 18 V·A
Average Holding Value 50 Hz 18 V·A
Average Holding Value 60 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Average Pull-in Value 60 Hz 210 V·A
Average Holding Value 50 / 60 Hz 18 V·A
Average Holding Value 50 Hz 18 V·A
Average Holding Value 60 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Average Pull-in Value 60 Hz 210 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Cable End 6 ... 10 mm²
Rigid Cable 6 ... 16 mm²
Flexible with Cable End 6 ... 10 mm²
Rigid Cable 6 ... 16 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Environmental

Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GOST Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
160 mm
Package Level 1 Depth / Length:
200 mm
Package Level 1 Height:
85 mm
Package Level 1 Gross Weight:
1.35 kg
Package Level 1 EAN:
3471522304841

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001079 - Capacitor contactor
ETIM 8:
EC001079 - Capacitor contactor
ETIM 9:
EC001079 - Capacitor contactor
eClass:
V11.0 : 27371006
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4756 >> Capacitor magnet contactor
ABB New Stock Image
ABB 1SBL371074R8011 ABB
Sale price €123,95
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Popular Downloads

EPLAN Data:
Data Sheet, Technical Information:
Instructions and Manuals:

Dimensions

Product Net Width:
82 mm
Product Net Depth / Length:
110 mm
Product Net Height:
108 mm
Product Net Weight:
1.05 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie):
(220 / 240 V) 55 °C 95 A
(690 V) 40 °C 115 A
(690 V) 70 °C 80 A
(220 / 240 V) 55 °C 95 A
(690 V) 40 °C 115 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 65 A
(440 V) 55 °C 65 A
(500 V) 55 °C 55 A
(690 V) 55 °C 43 A
(380 / 400 V) 55 °C 65 A
(220 / 230 / 240 V) 55 °C 65 A
(415 V) 55 °C 65 A
(440 V) 55 °C 65 A
(500 V) 55 °C 55 A
(690 V) 55 °C 43 A
(380 / 400 V) 55 °C 65 A
(220 / 230 / 240 V) 55 °C 65 A
Rated Operational Power AC-3 (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-3) 600 cycles per hour
(AC-1) 600 cycles per hour
(AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Power Loss:
at Rated Operating Conditions AC-1 per Pole 6.5 W
at Rated Operating Conditions AC-3 per Pole 1.5 W
at Rated Operating Conditions AC-1 per Pole 6.5 W
at Rated Operating Conditions AC-3 per Pole 1.5 W
Operate Time:
Between Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Between Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque:
Control Circuit 1 N·m
Main Circuit 4 N·m
Control Circuit 1 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA:
Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
Without Derating 3000 m

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
102 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Height:
152 mm
Package Level 1 Gross Weight:
1.16 kg
Package Level 1 EAN:
3471522406804

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4755 >> Contactors
1SBL377001R6911 ABB - AF63-30-11 48-130V 50Hz / 48-130V 60Hz / 48-130V DC

AF63-30-11 48-130V 50Hz / 48-130V 60Hz / 48-130V DC Contactor

1SBL377001R7000 ABB - AF63-30-00 100-250V 50Hz / 100-250V 60Hz / 100-250V DC

AF63-30-00 100-250V 50Hz / 100-250V 60Hz / 100-250V DC Contactor

1SBL379001R8111 ABB - AE63-30-11 24V DC
ABB 1SBL379001R8111 ABB - AE63-30-11 24V DC
Sale price€0,00
Sold Out

AE63-30-11 24V DC Contactor

1SBL379001R8611 ABB - AE63-30-11 110V DC

AE63-30-11 110V DC Contactor. AE63 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC.

1SBL387001R1100 ABB - AF65-30-00-11
ABB 1SBL387001R1100 ABB - AF65-30-00-11
Sale price €211,95
Only 7 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.97 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
027369a1-d0c4-4022-9c69-6abbc771eef0 France
Simplified SCIP:
35535b00-3559-41dd-ba43-4f10e10316a4 Czech Republic
eab94b80-8a80-493c-9b92-a73ba592b112 Bulgaria
dcb8ee84-7120-4a48-bd69-16f72ce443f5 Sweden
cce3ac24-2a61-4686-beaf-6178155141b3 Poland
d42934c1-6c5f-4ef4-9ee5-58c3d526687e France
a689c760-751b-4be4-9f82-9176d1b466bb Sweden
c7c9c97f-5bca-4709-9586-d42c0311f03f Germany
278fd4bb-b087-4d60-a153-2d45942126de Germany
19e79a30-187e-4fda-8fea-3e3963ed76bf Hungary
782a537f-1341-4633-abd5-e826adedf2b8 Germany
d3d144f1-0adf-4d10-a04e-b2831a583ba1 Finland
6dd99915-339b-4386-8a21-21cfda9179e8 Belgium
c9344780-ca4c-42bc-952d-9ef02731fd68 Germany
ca62b1a6-c5e6-4254-bbb4-b9377bac6bdc Poland
d49929ae-44fe-47fe-8264-37dd194ef189 Netherlands
6b5ee982-c1a5-4508-88cb-aac7acc86fcd Hungary
a0f4e357-48ca-4b01-8198-2410812bfbff Estonia
fcd03632-5a3f-470f-9b24-1d81b191430f Greece
31a286b7-17ad-4cbe-9ff8-b9686a9c51df Portugal
e6e14e05-3bfe-4fac-8dde-d71994626c82 Spain
7bdeae90-e0e6-44e4-b876-bafc74500ced Belgium
29e8a32f-4c66-4174-b78a-63ba758f264e Poland
554d77c8-5237-45c6-8a9e-e6406cd77688 Norway
9ebeae57-c6a8-4e04-89a3-103511571c08 Italy
5ad226d6-8b3d-417b-919a-610bbad4ed52 Denmark
fa566f5f-f2e2-4378-8324-6f1e0688d760 Germany
f7e65b7c-a14e-401f-9592-548b5c76fe12 Croatia
35535b00-3559-41dd-ba43-4f10e10316a4 Czech Republic
eab94b80-8a80-493c-9b92-a73ba592b112 Bulgaria
dcb8ee84-7120-4a48-bd69-16f72ce443f5 Sweden
cce3ac24-2a61-4686-beaf-6178155141b3 Poland
d42934c1-6c5f-4ef4-9ee5-58c3d526687e France
a689c760-751b-4be4-9f82-9176d1b466bb Sweden
c7c9c97f-5bca-4709-9586-d42c0311f03f Germany
278fd4bb-b087-4d60-a153-2d45942126de Germany
19e79a30-187e-4fda-8fea-3e3963ed76bf Hungary
782a537f-1341-4633-abd5-e826adedf2b8 Germany
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.07 kg
Package Level 1 EAN:
3471523132610
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.7 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707046
E-Number (Sweden):
3210042
1SBL387001R1111 ABB - AF65-30-11-11
ABB 1SBL387001R1111 ABB - AF65-30-11-11
Sale price€0,00
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
67 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.01 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
d9555361-1018-40d6-8cb6-e7f85987becf France
Simplified SCIP:
dd548c6c-8a3f-4476-90e3-f9f83be0033b Germany
31e74b10-7e43-4a14-bef4-ba0a183e22e6 Poland
7f89b93f-0ece-483b-b26c-81e41e5c53ea Norway
924eba1e-bc3f-4014-b04c-f29972c71585 Germany
5359db27-b2ad-4000-823a-b636cf3b6231 Poland
d528f1da-4f9e-4d07-904c-9f15fbe5a5d5 Netherlands
2819f27d-e610-4db5-a32b-e2bd4334e7bd Hungary
f37ef345-30aa-49ef-9598-66cefb0dd647 Estonia
4213a7e1-e3d7-4a64-9a3e-1d2a59f04706 Italy
0e54bdeb-83e9-4b3b-a93f-7d1c4b59b1db Denmark
1bcf7450-2b2e-4b5b-be66-433f7a943ca9 Germany
df94d61c-6fa2-4c2a-989d-38f1adb140f3 Croatia
8897530c-0c09-4f97-84e3-923277a4b557 Czech Republic
4ab3341d-b66c-44b1-9761-4127f45effdc Bulgaria
fd24c700-2cfa-47ab-8024-a29d13452d92 Sweden
cd46be2d-d45a-4abc-b1a9-db0cdae0eee8 Poland
cadd27a0-1b24-4ead-8be5-861fc09ac579 France
1fdf8b88-59ca-4d2f-b310-602c0b989fec Sweden
c8dff54d-4c97-4b68-b235-a29e3104acfb Germany
bbff211e-c9fb-4a99-8ac6-ad91769868d2 Germany
27919ef0-8e9e-4279-9711-a13b1e8355ba Hungary
2f698bde-c79c-4be4-ace3-e3eaad848aa5 Greece
d06b297f-54e4-4c14-8db5-a20a39f42802 Portugal
075167b1-d405-4e52-85d6-e10c2049cc96 Spain
4e75e7cc-35f7-4d0d-9e96-fcdc69c42f71 Belgium
4222f957-ffd0-4155-9060-dee2baf2a32d Finland
9a9750a6-82af-4bee-8f7f-eaed4f33f23d Belgium
dd548c6c-8a3f-4476-90e3-f9f83be0033b Germany
31e74b10-7e43-4a14-bef4-ba0a183e22e6 Poland
7f89b93f-0ece-483b-b26c-81e41e5c53ea Norway
924eba1e-bc3f-4014-b04c-f29972c71585 Germany
5359db27-b2ad-4000-823a-b636cf3b6231 Poland
d528f1da-4f9e-4d07-904c-9f15fbe5a5d5 Netherlands
2819f27d-e610-4db5-a32b-e2bd4334e7bd Hungary
f37ef345-30aa-49ef-9598-66cefb0dd647 Estonia
4213a7e1-e3d7-4a64-9a3e-1d2a59f04706 Italy
0e54bdeb-83e9-4b3b-a93f-7d1c4b59b1db Denmark
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.11 kg
Package Level 1 EAN:
3471523132719
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
11.1 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707062
1SBL387001R1200 ABB - AF65-30-00-12
ABB 1SBL387001R1200 ABB - AF65-30-00-12
Sale price €336,95
Only 1 unit left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.97 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
50 Hz 48 ... 130 V
60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
3fec47c1-c65d-4305-9c2e-7df042a1cddc China
Simplified SCIP:
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
f17ed004-abba-409b-a805-15157aa55e3a Germany
bc1ad85e-d612-47e6-97e2-5de4b0fa54be Sweden
c92a120b-91ae-4036-a235-6fe1cdaa62ab France
8c38c27a-ad0d-417a-9d95-acad06fa6062 Germany
ac1e48ae-9d93-463a-93d6-ddcba42a4a00 Spain
0293f116-3a57-479f-9fa2-8c8d8487a6fb Belgium
56cd4198-8e96-4f6d-97de-c408253f9825 Portugal
44049422-87ff-4bac-bd16-be9d1b535380 Germany
bcc1f3eb-a8a8-44a8-b43f-1899bcaf6d00 Greece
b1bfb508-b884-456c-a369-ae91028a4c67 Bulgaria
b97cfb2f-06b1-4231-94dd-ebc2b2e51de3 Hungary
8042fc92-672d-4056-b2ee-c30c715d04df Norway
11871a04-5b59-4c36-857a-37307ce804cb Netherlands
3d6e31e2-8770-4907-9552-191b765cbc0f Poland
5ac7a695-f072-44eb-a881-5471b74ec908 Finland
d223af47-6a31-49a2-96e0-bdb74606c444 Estonia
a4b16553-4a18-4d45-b271-0f89e979bae1 Hungary
75ebf583-bced-418c-a7f7-418cf0b176cd Croatia
92b1b900-6889-4556-870d-e840c5c7ddc3 Czech Republic
c6696631-ee4d-4b23-941c-f72289397078 Poland
14f7f3bb-3e2e-45a9-8265-1b3e7cfc71fb Germany
60ca3568-0d88-49a3-bc26-f1addf655b9d Belgium
d8e9cb6c-5b25-487a-980a-96f6ccd14b48 Denmark
45d93a48-14aa-491a-bab7-ca938aa458df Sweden
21a23aed-a8bc-4efd-b0de-f9f4d9a6d89c France
b532e39a-d001-4747-a9e5-f51ae9eb6b9f Poland
02c35782-57c1-4092-bb10-16e2647cc2f8 Germany
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.07 kg
Package Level 1 EAN:
3471523132627
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.7 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707047
E-Number (Sweden):
3210043
1SBL387001R1300 ABB - AF65-30-00-13
ABB 1SBL387001R1300 ABB - AF65-30-00-13
Sale price €149,95
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.95 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
e9b43d1b-dd25-4049-9500-e96dae069812 France
Simplified SCIP:
4f8f9097-4d3f-40f2-ab71-de08f01520c1 Poland
3c9c39cd-1f36-40cb-bd2e-cbdb489ca0d3 Norway
7ee99c18-1a43-42d9-8de2-80aefe2bc295 Spain
5c5a0e9f-1f11-470e-a9eb-5d5eae2ce325 Germany
49cec99c-43cf-4caf-a582-f7fddb48fa78 Finland
242d911d-693f-4802-9162-38f75bfbf158 Italy
034afccd-5d3c-4f17-a5d4-41c3d33662aa Germany
a7cbf824-baa3-405d-b1f0-9b43b9a5c174 Netherlands
9112a6a0-74e8-4e47-89ba-c82c10a2be98 Greece
7b2d5a1d-bfe8-4627-b7a9-4817986425e5 Denmark
d83d4331-2a05-4711-a887-a739649a699a Germany
2c45b13f-ccd4-438b-893d-a1fd3a931798 Czech Republic
4935f90b-1a61-4100-9d9b-b7f0480976a4 Poland
2d663d0b-9e40-4dcd-b3b3-908840fa7414 Sweden
26f7d5b6-c240-4975-ad30-c60b9a55b4ec Poland
cb6c25f4-3570-4f71-9b53-994499d0f1f5 France
a031f8e6-578e-42c3-85bd-8ce5128a8b44 Portugal
22cf40dd-3fdc-46aa-aa67-9a7c3429b359 Hungary
5b11f3b5-236c-45a1-bf65-22616ac89baf Belgium
c918f036-cd2d-40ce-9a0a-0d21cc7e8ede Bulgaria
48dcdcfb-6ae6-4ee9-8d97-071323301bbd Sweden
7f440d90-9fa6-45bc-8dd8-3fc8af21a148 Germany
3bada221-ca3f-45e1-be5a-cc897c807c4d Germany
4f8f9097-4d3f-40f2-ab71-de08f01520c1 Poland
3c9c39cd-1f36-40cb-bd2e-cbdb489ca0d3 Norway
7ee99c18-1a43-42d9-8de2-80aefe2bc295 Spain
5c5a0e9f-1f11-470e-a9eb-5d5eae2ce325 Germany
49cec99c-43cf-4caf-a582-f7fddb48fa78 Finland
242d911d-693f-4802-9162-38f75bfbf158 Italy
034afccd-5d3c-4f17-a5d4-41c3d33662aa Germany
a7cbf824-baa3-405d-b1f0-9b43b9a5c174 Netherlands
9112a6a0-74e8-4e47-89ba-c82c10a2be98 Greece
7b2d5a1d-bfe8-4627-b7a9-4817986425e5 Denmark
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.05 kg
Package Level 1 EAN:
3471523132634
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.5 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707048
E-Number (Sweden):
3210045
1SBL387001R1311 ABB - AF65-30-11-13
ABB 1SBL387001R1311 ABB - AF65-30-11-13
Sale price €200,95
Only 10 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
67 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.99 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
914195be-edbe-4da9-a540-aaf8479170b1 France
Simplified SCIP:
2bc2b73f-ee56-4c7c-adcf-ee80a8c2e217 Norway
7eee294c-c2ca-41ac-baa5-15a39944afed Belgium
52cccffb-3c0d-4397-8d47-c53653ae9664 Belgium
1f1de755-c9bf-438e-8463-7870089e9916 Germany
42a84bc3-0f3b-45dd-ac2f-c1d4918c5692 Denmark
6421007a-9f5c-4854-aa73-35bada14bb9c Germany
791e7dba-7f60-4f78-862d-2c64d81aeb36 Italy
c7dd49c2-04d0-4cf3-b256-7b285d4688d0 Sweden
90068660-a9a7-4e89-a7e4-e70e84502ded France
c3c2098d-6622-427f-8374-291039f594b0 Poland
e71d1576-c243-44c7-9e1e-6dab2f66bf51 Sweden
44a79182-2263-47b3-a434-1d561fa023a1 Netherlands
5d687c66-b5ee-4ad2-a5da-2741eae4ee88 Poland
533f7962-f838-4bc1-8fb9-db711551d188 Czech Republic
8b4d4e2a-5814-4c6a-acdc-4d953b70dc68 Croatia
a59b59f3-e7b8-4580-a038-7c6e559b0fdb Spain
a4c18f00-ec68-4625-963b-66967dc73cc7 Hungary
dacf0edb-b00d-4515-b3a1-b7ca44c9818d Germany
6c8322b1-feea-4305-ae8d-92626d3f6d9c Germany
616f83c9-8ff4-4c49-8396-424c2a8f43d1 Finland
3fbf1da9-11be-486c-89a6-2a4511729697 Poland
e4262111-ddbe-4f3f-91ff-230296cdd91b Bulgaria
153f4005-a60b-49bc-8642-6c6252acbd71 Portugal
b33ef4f8-3bfd-4628-a880-b37a49288f33 Greece
d882dd44-dc86-46e1-878c-db152f85d4c7 Estonia
61a130a7-ef77-45aa-8b50-dd616c7a7698 Germany
052a8507-d201-4b11-b758-13d003bfb2b0 Hungary
2bc2b73f-ee56-4c7c-adcf-ee80a8c2e217 Norway
7eee294c-c2ca-41ac-baa5-15a39944afed Belgium
52cccffb-3c0d-4397-8d47-c53653ae9664 Belgium
1f1de755-c9bf-438e-8463-7870089e9916 Germany
42a84bc3-0f3b-45dd-ac2f-c1d4918c5692 Denmark
6421007a-9f5c-4854-aa73-35bada14bb9c Germany
791e7dba-7f60-4f78-862d-2c64d81aeb36 Italy
c7dd49c2-04d0-4cf3-b256-7b285d4688d0 Sweden
90068660-a9a7-4e89-a7e4-e70e84502ded France
c3c2098d-6622-427f-8374-291039f594b0 Poland
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.09 kg
Package Level 1 EAN:
3471523132733
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.9 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707074
1SBL387001R1400 ABB - AF65-30-00-14
ABB 1SBL387001R1400 ABB - AF65-30-00-14
Sale price€0,00
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.95 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
50 Hz 250 ... 500 V
60 Hz 250 ... 500 V
DC Operation 250 ... 500 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.05 kg
Package Level 1 EAN:
3471523132641
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.5 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707049
E-Number (Sweden):
3210047
1SBL387001R4100 ABB - AF65-30-00-41
ABB 1SBL387001R4100 ABB - AF65-30-00-41
Sale price€0,00
Sold Out

AF65-30-00-41 CONTACTOR 3P 65A 24-60V50 / 60HZ

1SBL387082R1122 ABB - AFS65-30-22-11
ABB 1SBL387082R1122 ABB - AFS65-30-22-11
Sale price €429,95
Only 1 unit left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
144 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.02 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
2
Number of Auxiliary Contacts NC:
2
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque:
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
Declaration of Conformity - UKCA:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
167 mm
Package Level 1 Depth / Length:
180 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.16 kg
Package Level 1 EAN:
3471523157811
Package Level 2 Units:
box 6 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
6.96 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3708059
E-Number (Sweden):
3210671
1SBL387082R1322 ABB - AFS65-30-22-13
ABB 1SBL387082R1322 ABB - AFS65-30-22-13
Sale price€0,00
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
144 mm
Product Net Height:
125.5 mm
Product Net Weight:
1 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
2
Number of Auxiliary Contacts NC:
2
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque:
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
Declaration of Conformity - UKCA:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
167 mm
Package Level 1 Depth / Length:
180 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.14 kg
Package Level 1 EAN:
3471523157835
Package Level 2 Units:
box 6 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
6.84 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3708070
E-Number (Sweden):
3210672
1SBL397001R1100 ABB - AF80-30-00-11
ABB 1SBL397001R1100 ABB - AF80-30-00-11
Sale price €203,95
In stock, 11 units

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
116 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.22 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Power AC-3 (Pe):
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe):
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 17 mm
Control Circuit 10 mm
Main Circuit 17 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
3
Continuous Current Rating NEMA:
90 A
Horsepower Rating NEMA:
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 105 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
103 mm
Package Level 1 Gross Weight:
1.34 kg
Package Level 1 EAN:
3471523132917
Package Level 2 Units:
box 8 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.72 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707120
E-Number (Sweden):
3210050
1SBL397001R1111 ABB - AF80-30-11-11
ABB 1SBL397001R1111 ABB - AF80-30-11-11
Sale price €257,95
Only 5 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
82 mm
Product Net Depth / Length:
116 mm
Product Net Height:
125.5 mm
Product Net Weight:
1.26 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 1000 V
Auxiliary Circuit 690 V
Main Circuit 1000 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
(690 V) 40 °C 125 A
(690 V) 60 °C 100 A
(690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(1000 V) 60 °C 25 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
(415 V) 60 °C 80 A
(440 V) 60 °C 80 A
(500 V) 60 °C 65 A
(690 V) 60 °C 49 A
(380 / 400 V) 60 °C 80 A
(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
(72 V) 1-Pole, 60 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
(72 V) 2 Poles in Series, 40 °C 125 A
(72 V) 2 Poles in Series, 60 °C 100 A
(72 V) 2 Poles in Series, 70 °C 85 A
(72 V) 3 Poles in Series, 40 °C 125 A
(72 V) 3 Poles in Series, 60 °C 100 A
(72 V) 3 Poles in Series, 70 °C 85 A
(110 V) 2 Poles in Series, 40 °C 125 A
(110 V) 2 Poles in Series, 60 °C 100 A
(110 V) 2 Poles in Series, 70 °C 85 A
(110 V) 3 Poles in Series, 40 °C 125 A
(110 V) 3 Poles in Series, 60 °C 100 A
(110 V) 3 Poles in Series, 70 °C 85 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 100 A
(220 V) 3 Poles in Series, 70 °C 85 A
(72 V) 1-Pole, 40 °C 125 A
Rated Operational Current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe):
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(400 V) 37 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(1000 V) 35 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe):
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
(415 V) 45 kW
(440 V) 45 kW
(500 V) 45 kW
(690 V) 45 kW
(380 / 400 V) 37 kW
(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
for 0.1 s 140 A
for 1 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
at 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 7.6 W
at Rated Operating Conditions AC-3 per Pole 3 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Flexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 17 mm
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 17 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Auxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
3
Continuous Current Rating NEMA:
90 A
Horsepower Rating NEMA:
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 25 Hp
(230 V AC) Three Phase 30 Hp
(460 V AC) Three Phase 50 Hp
(575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 105 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 25 hp
(220 ... 240 V AC) Three Phase 30 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 60 hp
(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSA:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 78.2 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
103 mm
Package Level 1 Gross Weight:
1.38 kg
Package Level 1 EAN:
3471523133013
Package Level 2 Units:
box 8 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
11.04 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707125

Recently viewed