Specifications
Model |
AP-14SK |
|||
Type |
Positive (High) Sensor Head |
|||
Rated pressure |
0 to 1450 PSI |
|||
Fluid type |
Gases and liquids compatible with 304 and 630 stainless steel |
|||
Type of pressure |
Gauge pressure |
|||
Repeatability |
0.5 % of F.S. max. |
|||
Connection port |
1/4 NPT (with a throttle) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
2900 PSI |
|||
Ambient temperature |
-20 to +100°C ( -4 to 212°F ), No condensation*1 |
|||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively |
|||
Shock resistance |
500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total) |
|||
Material |
Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only) |
|||
Accessories |
Sensor head connector: 1 |
|||
Weight |
Approx. 130 g |
|||
*1 The cable is resistant to temperatures between -20 and 80°C ( -4 and 176°F ). | ||||


Specifications
Model |
AP-15SK |
|||
Type |
Positive (High) Sensor Head |
|||
Rated pressure |
0 to 2900 PSI |
|||
Fluid type |
Gases and liquids compatible with 304 and 630 stainless steel |
|||
Type of pressure |
Gauge pressure |
|||
Repeatability |
0.5 % of F.S. max. |
|||
Connection port |
1/4 NPT (with a throttle) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
5800 PSI |
|||
Ambient temperature |
-20 to +100°C ( -4 to 212°F ), No condensation*1 |
|||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively |
|||
Shock resistance |
500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total) |
|||
Material |
Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only) |
|||
Accessories |
Sensor head connector: 1 |
|||
Weight |
Approx. 130 g |
|||
*1 The cable is resistant to temperatures between -20 and 80°C ( -4 and 176°F ). | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-16SK |
|||
Type |
Positive (High) Sensor Head |
|||
Rated pressure |
0 to 7250 PSI |
|||
Fluid type |
Gases and liquids compatible with 304 and 630 stainless steel |
|||
Type of pressure |
Gauge pressure |
|||
Repeatability |
0.5 % of F.S. max. |
|||
Connection port |
1/4 NPT (with a throttle) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pressure resistance |
10875 PSI |
|||
Ambient temperature |
-20 to +100°C ( -4 to 212°F ), No condensation*1 |
|||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively |
|||
Shock resistance |
500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total) |
|||
Material |
Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only) |
|||
Accessories |
Sensor head connector: 1 |
|||
Weight |
Approx. 130 g |
|||
*1 The cable is resistant to temperatures between -20 and 80°C ( -4 and 176°F ). | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-31A |
|||
Type |
Negative pressure, Analog, NPN |
|||
Rated pressure |
0 to -101.3 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
NPN open collector: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
AP-31K |
|||
Type |
Negative pressure, NPN |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") |
|||
Display resolution |
0.1 inchHg, 0.1 kPa, 1 mmHg, 0.001 bar |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
72.5 PSI |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
AP-31KP |
|||
Type |
Negative pressure, PNP |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") |
|||
Display resolution |
0.1 inchHg, 0.1 kPa, 1 mmHg, 0.001 bar |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
72.5 PSI |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-31ZA |
|||
Type |
Negative pressure, Zero shift, NPN |
|||
Rated pressure |
0 to -101.3 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
- |
||
Zero-shift input |
Input time: 20 ms or more |
|||
Control output |
NPN open collector: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
AP-31ZP |
|||
Type |
Negative-pressure Type, PNP |
|||
Rated pressure |
0 to -101.3 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Zero-shift input |
Input time: 20 ms or more |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AP-32K |
|||
Type |
Positive pressure, NPN |
|||
Rated pressure |
0 to 14.50 PSI |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") |
|||
Display resolution |
0.02 Psi, 0.1 kPa, 0.001 kgf/cm2, 0.001 bar |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
72.5 PSI |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
AP-32KP |
|||
Type |
Positive pressure, PNP |
|||
Rated pressure |
0 to 14.50 PSI |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") |
|||
Display resolution |
0.02 Psi, 0.1 kPa, 0.001 kgf/cm2, 0.001 bar |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
72.5 PSI |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g |
|||

Specifications
Model |
AP-32ZP |
|||
Type |
Positive-pressure Type, PNP |
|||
Rated pressure |
0 to 100.0 kPa |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure, air or non-corrosive gases |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/s |
|||
Display resolution |
0.1 kPa (0.001 bar) |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Hysteresis |
Variable (when hysteresis mode is selected), 0.5 % of F.S. in standard mode |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Zero-shift input |
Input time: 20 ms or more |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,Pressure port: Die-cast zinc, Cable: Oil-proof cabtyre cable |
|||
Accessories |
Mounting bracket A, mounting bracket B, hexagon socket head cap plug |
|||
Weight |
Approx. 120 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.