Keyence

6950 products

Showing 5713 - 5736 of 6950 products

Showing 5713 - 5736 of 6950 products
View
Keyence Stock Image
Keyence SJ-E036A Keyence
Sale price €2.416,95
Only 9 units left

Specifications

Model

SJ-E036A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

420 mm 16.54"*3

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

670 g 23.63oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E036H Keyence
Sale price €1.740,95
Only 2 units left

Specifications

Model

SJ-E036H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

420 mm 16.54"*3

Total length

350 mm 13.78"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

680 g 23.99oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-E036L Keyence
Sale price €981,95
Only 6 units left

Specifications

Model

SJ-E036L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

440 mm 17.32"*3

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

670 g 23.63oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060A Keyence
Sale price €1.736,95
Only 4 units left

Specifications

Model

SJ-E060A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

660 mm 25.98"*3

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

850 g 29.98oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E060H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

660 mm 25.98"*3

Total length

560 mm 22.05"

No. ofelectrodes

17

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

870 g 30.69oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060L Keyence
Sale price €815,95
Only 1 unit left

Specifications

Model

SJ-E060L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

680 mm 26.77"*3

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

850 g 29.98oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084A Keyence
Sale price €2.980,95
Only 1 unit left

Specifications

Model

SJ-E084A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

900 mm 35.43"*3

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1070 g 37.74oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E084H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

900 mm 35.43"*3

Total length

800 mm 31.50"

No. ofelectrodes

25

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1100 g 38.80oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084L Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E084L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

920 mm 36.22"*3

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1070 g 37.74oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E108A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E108A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1140 mm 44.88"*3

Total length

1040 mm 40.94"

No. ofelectrodes

17

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1270 g 44.80oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E108H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E108H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1140 mm 44.88"*3

Total length

1040 mm 40.94"

No. ofelectrodes

33

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1300 g 45.86oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E108L Keyence
Sale price €4.093,95
Only 1 unit left

Specifications

Model

SJ-E108L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1160 mm 45.67"*3

Total length

1040 mm 40.94"

No. ofelectrodes

17

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1270 g 44.80oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E132A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E132A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1380 mm 54.33"*3

Total length

1280 mm 50.39"

No. ofelectrodes

21

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1500 g 52.91oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E132H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E132H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1380 mm 54.33"*3

Total length

1280 mm 50.39"

No. ofelectrodes

41

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1550 g 54.67oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E132L Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E132L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1400 mm 55.12"*3

Total length

1280 mm 50.39"

No. ofelectrodes

21

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1500 g 52.91oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E156A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E156A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1620 mm 63.78"*3

Total length

1520 mm 59.84"

No. ofelectrodes

25

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1700 g 59.97oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E156H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E156H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1620 mm 63.78"*3

Total length

1520 mm 59.84"

No. ofelectrodes

49

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1750 g 61.73oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E156L Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E156L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1640 mm 64.57"*3

Total length

1520 mm 59.84"

No. ofelectrodes

25

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1700 g 59.97oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E180A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E180A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1860 mm 73.23"*3

Total length

1760 mm 69.29"

No. ofelectrodes

29

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1900 g 67.02oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E180H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E180H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1860 mm 73.23"*3

Total length

1760 mm 69.29"

No. ofelectrodes

57

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1950 g 68.78oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E180L Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E180L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1880 mm 74.02"*3

Total length

1760 mm 69.29"

No. ofelectrodes

29

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1900 g 67.02oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E204A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E204A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

2100 mm 82.68"*3

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2100 g 74.08oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E204H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E204H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

2100 mm 82.68"*3

Total length

2000 mm 78.74"

No. ofelectrodes

65

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2150 g 75.84oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E204L Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-E204L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

2120 mm 83.46"*3

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2100 g 74.08oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Recently viewed