Specifications
Model |
EH-614A |
|||
Type |
Standard , Shielded , ULTRA thin |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
15 x 15 mm 0.59" x 0.59" |
|||
Stable detecting range |
0 to 5 mm0.20" |
|||
Maximum detecting distance |
8 mm0.31" |
|||
Hysteresis |
0.05 mm0.002" |
|||
Repeatability |
0.005 mm0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 57 g (including nuts and 3-m 9.8' cable) |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LR-W500C |
|||
Type |
M12 connector 4-pin type |
|||
Detecting distance |
30 to 500 mm 1.18" to 19.69" |
|||
Min. spot diameter |
Adjustable spot |
|||
Light source |
White LED |
|||
Mutual interference reduction function |
Up to 2 units when alternate frequencies set |
|||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Response time |
200 µs/1 ms/10 ms/100 ms/500 ms selectable *1 |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
External input |
Tuning /Transmission OFF selectable |
|||
Protection circuit |
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection |
|||
Power supply |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Current consumption |
65 mA or less (without load) at 24 VDC; |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less |
|||
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Weight |
Approx. 110 g |
|||
*1 When alternate frequencies are set, the response time increases by approximately 20%. | ||||

Specifications
Model |
LR-ZB100CP |
|||
Type |
Distance based laser sensor |
|||
Appearance |
Rectangular |
|||
Output |
PNP |
|||
Cable connection |
M8 connector, 4-pin |
|||
Detectable distance |
35 to 100 mm 1.38" to 3.94" (650 to 0)*1 |
|||
Standard detectable deviation |
35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06" |
|||
Display resolution |
2 (0.2 mm 0.008") |
|||
Spot size |
Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 1 laser product |
|||
Function |
Indicator |
3-digit 7-segment display (red), |
||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
PNP Open collector, |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 4,000 lux or less |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F (No freezing) |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, |
|||
Accompanying items |
Instruction Manual, |
|||
Weight |
Approx. 55 g |
|||
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

EtherCAT Coupler Unit, 46 MM x 71 MM x 100 MM, 5 to 24 VDC, 4 A, 1.45 W, 63-Input, EtherCAT Coupler Unit for Automation Control System Networking Distributed Input/Output.

Specifications
Model |
FS-N41C*1 |
|||
Type |
M8 Connector*2 |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
23 µs (S-HSPD*3) /50 µs (HSPD*4) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
2*5 |
|||
Number of external inputs |
1*5 |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*6 |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*7 |
||
Power consumption |
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*9 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 25 g |
|||
*1 IO-Link Specifi cation V.1.1/COM2 (38.4 kbps) is supported. | ||||

Specifications
Model |
LR-ZB250CP |
|||
Type |
Distance based laser sensor |
|||
Appearance |
Rectangular |
|||
Output |
PNP |
|||
Cable connection |
M8 connector, 4-pin |
|||
Detectable distance |
35 to 250 mm 1.38" to 9.84" (215 to 0)*1 |
|||
Standard detectable deviation |
35 to 180 mm 1.38" to 7.09": 9 mm 0.35" |
|||
Display resolution |
1 to 3 (1 to 3 mm 0.04" to 0.12") |
|||
Spot size |
Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 1 laser product |
|||
Function |
Indicator |
3-digit 7-segment display (red), |
||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
PNP Open collector, |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 2,000 lux or less |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F (No freezing) |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, |
|||
Accompanying items |
Instruction Manual, |
|||
Weight |
Approx. 55 g |
|||
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-13*1 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R2 mm0.079" Tough-Flex |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 8 g |
|||