Power Distribution & Protection

16320 products

Showing 13609 - 13632 of 16320 products

Showing 13609 - 13632 of 16320 products
View
5SY5225-7 Siemens
Siemens 5SY5225-7 Siemens
Sale price€0,00
Sold Out
Product
Article Number (Market Facing Number) 5SY52257 | 5SY52257
Product Description Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, C, 25A
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4001869226712
UPC Not available
Commodity Code 85362010
LKZ_FDB/ CatalogID LV10.1
Product Group 5505
Group Code P310
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.705 lb
Package size unit of measure Inch
Packaging Quantity 1
3RT1024-1BG40 Siemens
Siemens 3RT1024-1BG40 Siemens
Sale price€0,00
Sold Out
Product
Article Number (Market Facing Number) 3RT10241BG40
Product Description Power contactor, AC-3 12 A, 5.5 kW / 400 V 125 V DC, 3-pole, Size S0 Screw terminal !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2024-1BG40<<
Product family Not available
Product Lifecycle (PLM) PM500:Discontinued Product or end of PLM & Support
Additional Product Information
EAN 4011209511774
UPC Not available
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 3704
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 1.257 lb
Package size unit of measure Inch
Packaging Quantity 1
3VA1220-6EF32-0AA0 Siemens
Siemens 3VA1220-6EF32-0AA0 Siemens
Sale price €314,95
In stock, 11 units
Product
Article Number (Market Facing Number) 3VA12206EF320AA0
Product Description SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA12 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 200A 3-POLE Icu: (10KAIC AT 690V) (70KAIC AT 415V). TM240 TRIP UNIT WITH ADJUSTABLE Ir ADJUSTABLE Ii. SPECIAL FEATURES: CONNECTION WITH LUG TERMINAL / NUT KEEPER. DIMENSIONS (W x H x D) IN: 4.1 x 6.2 x 3.5.
Product family Ordering Data Overview
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4042948809402
UPC 804766421594
Commodity Code 85362090
LKZ_FDB/ CatalogID LV10.1
Product Group 5375
Group Code P360
Country of origin Czech Republic
SCIP number Not available
Delivery information
Net Weight (lb) 3.541 lb
Package size unit of measure Inch
Packaging Quantity 1
3VT1792-2DC36-0AA0 Siemens
Siemens 3VT1792-2DC36-0AA0 Siemens
Sale price€0,00
Sold Out

circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=25A rated current IR=20...25A overload protection II=250...375A, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact

Siemens Stock Image
Siemens 3VL2710-2LS36-0AA0 Siemens
Sale price €396,95
Only 3 units left
Buy the Siemens 3VL2710-2LS36-0AA0 Circuit Breaker - an industrial molded case circuit breaker providing overcurrent and short-circuit protection for electrical distribution. Features thermal-magnetic or electronic trip, high interrupting capacity, and UL/IEC ratings. The Siemens 3VL2710-2LS36-0AA0 is a direct replacement for existing breaker installations.
3KD4644-0QE40-0 Siemens
Siemens 3KD4644-0QE40-0 Siemens
Sale price€0,00
Sold Out

Switch disconnector 630 A, Size 4, 4-pole Side operating mechanism right Basic unit without handle flat terminal

3RW5526-3HA16 Siemens
Siemens 3RW5526-3HA16 Siemens
Sale price€0,00
Sold Out
Product
Article Number (Market Facing Number) 3RW55263HA16 | 3RW55263HA16
Product Description SIRIUS soft starter 200-690 V 77 A, 110-250 V AC spring-type terminals
Product family 3RW55 soft starters
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4047621040219
UPC Not available
Commodity Code 85371098
LKZ_FDB/ CatalogID CC-IC10
Product Group 4982
Group Code R711
Country of origin Czech Republic
SCIP number Not available
Delivery information
Net Weight (lb) 18.047 lb
Package size unit of measure in
Packaging Quantity 1
Schneider New Stock Image
Schneider A9A26904 Schneider
Sale price €76,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
LC1D096M7 Schneider Electric
Schneider LC1D096M7 Schneider Electric
Sale price€0,00
Sold Out

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-4
AC-1
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz

Complementary

Characteristic Value(s)
Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415 V AC 50/60 Hz (AC-3)
4 kW at 440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415 V AC 50/60 Hz (AC-3e)
4 kW at 440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phase motors
2 hp at 230/240 V AC 50/60 Hz for 3 phase motors
5 hp at 460/480 V AC 50/60 Hz for 3 phase motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 25 A (at 140 °F (60 °C)) for power circuit
10 A (at 140 °F (60 °C)) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s for power circuit
210 A 104 °F (40 °C) - 1 s for power circuit
30 A 104 °F (40 °C) - 10 min for power circuit
61 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole 1.56 W AC-1
0.2 W AC-3
0.2 W AC-3e
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 0.6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
2 Mcycles 9 A AC-3e <= 440 V
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz
0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz
1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 2…3 W at 50/60 Hz
Operating time 12...22 ms closing
4...19 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)
Power circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5
Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5
Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5
Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5
Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals pozidriv No 2 M3.5
Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals pozidriv No 2 M3.5
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
Schneider New Stock Image
Schneider LC1E95P7 Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
A9MEM1542 Schneider Electric
Schneider A9MEM1542 Schneider Electric
Sale price€0,00
Sold Out

energy sensor, PowerTag Monoconnect 63A 3P+N bottom position

LC1D40A3U7 Schneider Electric
Schneider LC1D40A3U7 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-1
AC-3
AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 240 V AC 50/60 Hz

Complementary

Characteristic Value(s)
Motor power kW 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 415...440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660...690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phase motors
30 hp at 575/600 V AC 50/60 Hz for 3 phase motors
10 hp at 200/208 V AC 50/60 Hz for 3 phase motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
60 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 104 °F (40 °C) - 10 s for power circuit
720 A 104 °F (40 °C) - 1 s for power circuit
72 A 104 °F (40 °C) - 10 min for power circuit
165 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole 2.4 W AC-3
5.4 W AC-1
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 60 A AC-1 <= 440 V
1.5 Mcycles 40 A AC-3 <= 440 V
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz
0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz
1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4...19 ms opening
12...26 ms closing
Connections - terminals Control circuit: spring terminals 1 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: flexible without cable end
Control circuit: spring terminals 2 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid without cable end
Tightening torque Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm)
Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.001…0.04 in² (0.75…25 mm²) hexagonal 0.2 in (4 mm)
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
LC1DT32ND Schneider Electric
Schneider LC1DT32ND Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 60 V DC

Complementary

Characteristic Value(s)
Compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 40 A 40 °C - 10 min for power circuit
84 A 40 °C - 1 min for power circuit
145 A 40 °C - 10 s for power circuit
240 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm - Ith 32 A 50 Hz for power circuit
Power dissipation per pole 2.5 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 1 Mcycles 32 A AC-1 at Ue <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.25 Uc (-40…70 °C):drop-out DC
0.7...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
Inrush power in W 5.4 W (at 20 °C)
Hold-in power consumption in W 5.4 W at 20 °C
Operating time 20 ±20 % ms opening
63 ±15 % ms closing
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver Philips No 2
Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Plate
Rail
LC1-F330M7 Schneider
Schneider LC1-F330M7 Schneider
Sale price €729,95
Only 5 units left

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

A9D77420 Schneider Electric
Schneider A9D77420 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 4P - 20 A - C Curve - 6000A/6kA - 30 mA - SI type

LC1D80Q7 Schneider Electric
Schneider LC1D80Q7 Schneider Electric
Sale price€0,00
Sold Out

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 380 V AC 50/60 Hz coil

LC2D093P7 Schneider Electric
Schneider LC2D093P7 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
product name TeSys Deca
Product or component type Reversing contactor
Device short name LC2D
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-1
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
16 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW 2.2 kW at 220...230 V AC 50 Hz
4 kW at 380...400 V AC 50 Hz
4 kW at 415...440 V AC 50 Hz
5.5 kW at 500 V AC 50 Hz
5.5 kW at 660...690 V AC 50 Hz
motor power HP (UL / CSA) 0.5 hp at 115 V AC 60 Hz for 1 phase motors
1 hp at 230/240 V AC 60 Hz for 1 phase motors
2 hp at 200/208 V AC 60 Hz for 3 phases motors
2 hp at 230/240 V AC 60 Hz for 3 phases motors
5 hp at 460/480 V AC 60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 230 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 16 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 30 A 40 °C - 10 min for power circuit
61 A 40 °C - 1 min for power circuit
105 A 40 °C - 10 s for power circuit
210 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance 2.5 mOhm - Ith 16 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Electrical durability 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 9 A AC-3 at Ue <= 440 V
Power dissipation per pole 0.2 W AC-3
1.56 W AC-1
Front cover With
Interlocking type Mechanical
Mounting support Rail
Plate
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications GL
UL
DNV
LROS (Lloyds register of shipping)
RINA
CCC
GOST
BV
CSA
Connections - terminals Power circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end
Power circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end
Control circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end
Control circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end
Operating time 12...22 ms closing
4...19 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Maximum operating rate 3600 cyc/h 60 °C

Complementary

Characteristic Value(s)
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit
A9Y72625 Schneider Electric
Schneider A9Y72625 Schneider Electric
Sale price€0,00
Sold Out

add-on residual current devices, Acti9 Vigi iCG40, 1P+N, 25 A, 30 mA, AC type

Schneider New Stock Image
Schneider LRD04C Schneider
Sale price €79,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAPK12 Schneider Electric
Schneider GVAPK12 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Shaft bracket
Device short name GVAP
Accessory / separate part category Control accessory

Complementary

Characteristic Value(s)
Product Compatibility GV3APN01
GV3APN02
GV3APN03
GV3APN04
LU9APN21
LU9APN22
LU9APN24
GVAPA1
Length 11.8 in (300 mm)
LC1D32U7 Schneider Electric
Schneider LC1D32U7 Schneider Electric
Sale price€0,00
Sold Out

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 240 V AC 50/60 Hz coil

LC1D093B7 Schneider Electric
Schneider LC1D093B7 Schneider Electric
Sale price€0,00
Sold Out

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

GV2L32 Schneider Electric
Schneider GV2L32 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD32 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2L
Device Application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 15 kW 400/415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 690 V AC 50/60 Hz
Breaking capacity 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
20 kA Icu 440 V AC 50/60 Hz IEC 60947-2
10 kA Icu 500 V AC 50/60 Hz IEC 60947-2
4 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
50 % 400/415 V AC 50/60 Hz IEC 60947-2
75 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 32 A
Magnetic tripping current 537.6 A
[Ith] conventional free air thermal current 32 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 1.8 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 2 x M4 screws)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.8 in (97 mm)
Product Weight 0.73 lb(US) (0.33 kg)
color Dark grey
A9XMBP02 Schneider Electric
Schneider A9XMBP02 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range Acti9
Product or component type Mounting kit
Device short name mounting kit for back panel
Accessory / separate part category Mounting accessory
Colour Black (RAL 7016)
Quantity per set 1 kit

Complementary

Characteristic Value(s)
Localisation on device Back
Mounting location Back to back
Range compatibility Acti 9 Acti9 Smartlink
Kit composition 2 x PA6 bracket
2 x steel screws and bolts for mounting
Compatibility code Mounting kit for back panel

Recently viewed