This product is part of the Modicon X80 range, a common platform of modules for Modicon M580 and M340 Programmable Automation Controllers (PAC). This cordset is an accessory of I/O module. The length of this cable is 5m. This product is robust, high quality and based on the latest innovative technology. It is furnished with free-end color-coded flying leads (conforming to DIN 47100) and 20-way removable terminal block for module side. It weighs 0.7kg. It is suitable for medium to large process applications. This cordset is compatible with Modicon X80 BMXAMO0210 analogue output module, Modicon X80 BMXAMM0600 analogue I/O module and Modicon X80 BMXAMO0210 analogue output module. Modicon X80 consists in a compatible modules common platform that reduce maintenance and training costs with same spare parts in stock, and unique training for different Programmable Automation Controllers (PAC).
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon X80 |
| Accessory / Separate Part Type | Preformed cordset |
| Product Compatibility | BMXAMI0410 BMXAMM0600 BMXAMO0210 |
| Electrical connection | 1 free end with color-coded flying leads 1 removable terminal block 20 ways module side |
| Cable length | 16.4 ft (5 m) |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Weight | 1.5 lb(US) (0.7 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon Quantum automation platform |
| Product or Component Type | Ethernet network TCP/IP module |
| Concept | Transparent Ready |
| Web server | Class B20 |
| Web services | Rack viewer Diagnostics via predefined web pages Data Editor (via PC terminal) |
| Communication Service | Modbus TCP messaging I/O scanning |
| Communication Port Protocol | Ethernet Modbus TCP/IP |
| Physical interface | MT/RJ - 100BASE-FX fiber optic RJ45 - 10BASE-T/100BASE-TX twisted pair |
| Transmission Rate | 10/100 Mbit/s |
Complementary
| Characteristic | Value(s) |
|---|---|
| Redundancy | Yes hot standby redundant architecture |
| Supply | Via the power supply of the rack |
| Marking | CE |
| Local signalling | 1 LED for 10 Mbps or 100 Mbps data rate (10 MB/100 MB) 1 LED for collision detection (Coll) 1 LED for download mode (Kernel) 1 LED for Ethernet module fault (Fault) 1 LED for Ethernet network status (RUN) 1 LED for full-duplex mode (Fduplex) 1 LED for module ready (Ready) 1 LED for network active (Link) 1 LED for rack operational (Active) 1 LED for transmission/reception activity (TxAct/RxAct) |
| Current consumption | 750 mA 5 V DC |
| Module format | Standard |
| Product Weight | 0.761 lb(US) (0.345 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon Quantum automation platform |
| Product or Component Type | Unity processor |
Complementary
| Characteristic | Value(s) |
|---|---|
| Mode of Transmission | Multi mode |
| Clock frequency | 266 MHz |
| Number of slots | 2 10 16 4 6 |
| Number of racks | 2 - local |
| Number of distributed I/O station | 63 1 3 Modbus Plus |
| Number of remote I/O station | 31 - 2 S908 remote I/O 31 - 2 ethernet Quantum remote I/O 16 - 2 ethernet X80 remote I/O |
| Discrete I/O number | 31744 inputs, 31744 outputs - remote 8000 inputs, 8000 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 0 - local - forbidden in Hot Standby application |
| Analogue I/O number | 500 inputs, 500 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 1984 inputs,1984 outputs - remote 0 - local - forbidden in Hot Standby application |
| Application specific I/O | High-speed interrupt inputs Serial link Accurate time stamping Counter |
| Communication Service | Ethernet router |
| Number of optional modules | 6 Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
| Maximum number of connections | 1 USB 2 AS-Interface - distributed 4 AS-Interface - remote 6 Ethernet TCP/IP - local 6 Modbus Plus - local 6 Profibus DP - local 1 Modbus RS232/485 Modbus/ASCII) |
| Integrated connection type | 1 Modbus Plus 1 Modbus 1 USB 1 optic fibre Hot Standby |
| Checks | Process control Hot standby |
| Memory description | Expandable 7168 kB - program with PCMCIA card Expandable 8 MB - file storage with PCMCIA card Internal RAM 1024 kB - 512 kB for data |
| Switch Function | Key switch memory port on/off |
| Application structure | 1 periodic fast task - forbidden in Hot Standby application 128 I/O interrupt tasks - forbidden in Hot Standby application 128 interrupt tasks - forbidden in Hot Standby application 32 timer interrupt tasks - forbidden in Hot Standby application 4 auxiliary tasks - forbidden in Hot Standby application 1 cyclic/periodic master task - |
| Number of instructions per ms | 10.28 Kinst/ms 100 % Boolean 10.07 Kinst/ms 65 % Boolean and 35 % numerical |
| System overhead | 0.2 ms fast task 1 ms master task |
| Bus current requirement | 2500 mA |
| Local signalling | 1 LED (green) for Ethernet activity (COM) 1 LED (red) for Ethernet collision |
| Electrical connection | 1 female connector SUB-D 9 for connecting to the Modbus Plus network 1 connector RJ45 for connecting Modbus bus 1 connector MT-RJ (multimode fiber optic) for interconnecting primary and secondary PLCs up to 4 km |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon Quantum |
| Product or Component Type | Ethernet RIO drop adaptor |
| Number of port | 3 |
| Integrated connection type | Ethernet IP/Modbus TCP service port Ethernet IP/Modbus TCP device network |
| Communication Port Protocol | Ethernet IP/Modbus TCP |
| Communication Service | The input data are collected and published to the remote I/O head adaptor Output modules are updated with the data received from remote I/O head adaptor |
Complementary
| Characteristic | Value(s) |
|---|---|
| Topology | Daisy chain loop |
| Local signalling | 1 LED (green/red) for module status (Mod Status) 1 LED (green/red) for network communication status (Net Status) 1 LED (green) for RUN 1 LED (red) for I/O |
| Product Compatibility | 140CRP31200 |
| Environmental characteristic | Standard environment Hazardous location class I division 2 EN/IEC 61131-1 |
| Width | 6.6 in (167 mm) |
| Height | 2.0 in (50 mm) |
| Product Weight | 1.221 lb(US) (0.554 kg) |

This preassembled cordset is part of the Modicon X80 modules. It is compatible with 32-channels I/O modules. It enables the connection between I/O of modules with 40-way connectors to Modicon Telefast ABE7 rapid wiring connection. It is equipped with one 40-way connector at one end and two HE 10 connectors at the other end, and is 2 meters long.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon X80 |
| Accessory / Separate Part Type | Preformed cordset |
| Accessory / separate part designation | Preformed cordset for Telefast Advantys ABE7 sub-bases |
| Accessory / separate part destination | For I/O module with 40-way connectors |
| Number of cables | 2 |
| Electrical connection | 1 connector 40 ways 2 connectors HE10 |
| Cable length | 6.6 ft (2 m) |
Complementary
| Characteristic | Value(s) |
|---|---|
| Total number of wires | 40 |
| Wire section | 0.0005 in² (0.324 mm²) |
| Product Weight | 1.39 lb(US) (0.63 kg) |

This product is part of the Modicon X80 range, a common platform of modules for Modicon M580 and M340 Programmable Automation Controllers (PAC). This discrete output module has 8 relay outputs. It is a discrete output module with an output voltage of 24V to 240V, 19V AC to 264V AC, 12V to 24V, 10V DC to 34V DC, a typical current consumption of 79mA at 3.3V DC. This product is robust, high quality and based on the latest innovative technology. It offers electrical durability of 100000, 1 million, 10 million, 150000, 1500000, 2 million, 300000, 3 million, 500000, 5 million, 700000 cycles and 2119902 hours of MTBF. It is an IP20 rated product. It weighs 0.145kg. It is suitable for medium to large process applications. This product is certified by EAC, Merchant Navy, CSA, RCM, CE and UL. It meets EN 61131-2, EN 61000-6-4, EN 61000-6-2 and EN 61010-2-201 standards. Modicon X80 consists in a compatible modules common platform that reduce maintenance and training costs with same spare parts in stock, and unique training for different Programmable Automation Controllers (PAC).
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon X80 |
| Product or Component Type | Discrete output module |
| Discrete output number | 8 EN/IEC 61131-2 |
| Discrete output type | Relay |
| Discrete output voltage | 24...240 V 19...264 V AC 12...24 V 10...34 V DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ith] conventional free air thermal current | 3 A |
| Insulation resistance | > 10 MOhm 500 V DC |
| Power dissipation in W | 2.7 W |
| Response time on output | < 10 ms activation < 8 ms deactivation |
| Typical current consumption | 79 mA 3.3 V DC |
| MTBF reliability | 2119902 H |
| Output overload protection | Use 1 fast blow fuse per channel or group of channel |
| Output overvoltage protection | Use discharge diode on each output DC Use RC circuit on each output AC Use ZNO surge limiter on each output AC |
| Output short-circuit protection | Use 1 fast blow fuse per channel or group of channel |
| Minimum switching current | 10 mA 5 V DC |
| Electrical durability | AC-15 100000 cycles 220 VA 200...240 V 0.35) AC-12 1000000 cycles 110 VA 110...120 V AC-12 1000000 cycles 220 VA 200...240 V AC-12 1000000 cycles 50 VA 48 V AC-15 1000000 cycles 110 VA 200...240 V 0.35) DC-12 1000000 cycles 24 W 24 V DC-13 1000000 cycles 24 W 24 V AC-15 10000000 cycles 10 VA 110...120 V 0.35) AC-15 10000000 cycles 10 VA 200...240 V 0.35) AC-15 150000 cycles 110 VA 110...120 V 0.35) AC-15 1500000 cycles 50 VA 110...120 V 0.35) AC-15 2000000 cycles 24 VA 48 V 0.35) DC-13 2000000 cycles 10 W 24 V DC-12 300000 cycles 40 W 24 V AC-15 3000000 cycles 50 VA 200...240 V 0.35) AC-12 500000 cycles 110 VA 48 V AC-12 500000 cycles 220 VA 110...120 V AC-15 5000000 cycles 10 VA 48 V 0.35) AC-15 500000 cycles 24 VA 24 V 0.35) AC-12 700000 cycles 50 VA 24 V |
| Status LED | 1 LED (Green) module operating (RUN) 1 LED per channel (Green) channel diagnostic 1 LED (Red) module error (ERR) 1 LED (Red) module I/O |
| Product Weight | 0.320 lb(US) (0.145 kg) |

Pulse I/O Module for CJ2M, NPN with 10 inputs (four interrupt/quickresponse and two high-speed counter inputs) and 6 outputs (two pulse and two PWM outputs)

PLC, 24 VDC supply, 18 x 24 VDC inputs, 12 x NPN outputs 0.3 A, 2 x analog inputs, 10K steps program + 32K words data memory, 1 x Ethernet port

CPU, 60K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max

Special I/O Unit, position control module, open-loop control by pulse train output/line-driver output, 2-axes, 1-allocated number, 250mA max @ 5/DC

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.




23 point PLC 13 x 24VDC inputs, 1 x 24VDC Output, 9 x Relay Out, 2 x Analog Input, 1 x Analog Output
PLC modules are the expansion and signal processing hardware that extend a programmable logic controller's capabilities beyond the base CPU, covering digital and analog I/O, specialty functions, communication interfaces, and power supply modules installed in the controller rack or station. PLC Direct supplies PLC modules as an independent supplier, carrying surplus sealed, refurbished, and used hardware for maintenance and replacement across the major PLC platforms deployed in installed automation systems.
Where Are PLC Modules Used in Industrial Environments?
PLC modules are used wherever a base PLC controller requires additional I/O channels, signal types, or functional capabilities beyond what the CPU alone provides, from local rack expansion to distributed I/O stations across a facility. These components are present in virtually every modular PLC installation, handling field signal acquisition, output control, specialty measurement, and network communication alongside the controller CPU.
Facilities and operations that depend on PLC modules include:
-
Discrete manufacturing plants expanding PLC I/O capacity at machine control panels and distributed field cabinets across production lines.
-
Food and beverage processing facilities adding analog input and output modules for temperature, pressure, and flow measurement in batch and continuous process control.
-
Automotive assembly operations using specialty function modules for high-speed counter inputs, encoder feedback, and motion control coordination.
-
Water and wastewater treatment plants extending PLC I/O across pump station control panels and remote treatment process equipment.
-
Packaging and material handling operations where high channel-count digital I/O modules handle the sensor and actuator density of automated sorting and conveyor systems.
A failed or discontinued PLC module in a production system requires a like-for-like replacement to restore the channel capacity and signal type that the controller program depends on.
Which Brands of PLC Modules Does PLC Direct Stock?
PLC Direct stocks PLC modules across the major controller platforms deployed in installed automation systems worldwide.
-
Siemens SIMATIC S7-1200, S7-1500, and ET 200SP modules: Analog input modules across the SM1231 series, digital I/O modules for S7-1200 and S7-1500 racks, and ET 200SP distributed I/O modules including AI and DI/DQ types with PROFINET interface modules confirmed in stock.
-
Omron CJ Series I/O and special function modules: CJ1W digital input, digital output, and analog I/O modules alongside special function modules including high-speed counter units and expansion I/O control units for installed CJ Series PLC architectures.
-
Schneider Electric Modicon Quantum and M580 I/O modules: Discrete and analog expansion modules for the Modicon Quantum 140-series platform and Modicon M580 BMEP/BMEH series, covering the full range of field signal types used in installed Modicon process and machine control systems.
-
B&R X20 System I/O modules: Digital and analog I/O modules, power supply modules, and interface components within the X20 modular system, used in machine and line automation architectures with POWERLINK communication.
PLC Direct carries PLC modules as surplus sealed, refurbished, and used hardware, giving maintenance teams options across condition grades and budget requirements.
What Should You Know Before Ordering PLC Modules?
Hardware condition options: PLC Direct supplies PLC modules in surplus sealed, refurbished, and used condition. Surplus sealed units are factory-sealed stock that has not been previously installed; refurbished modules have been inspected and tested to confirm operational functionality; used hardware is sourced from decommissioned systems and suits facilities managing lifecycle replacements under budget constraints.
Compatibility and part identification: PLC modules are platform-specific and must be matched to the correct controller series, rack or backplane type, and in some cases, firmware version of the installed CPU. A Siemens S7-1200 signal module, for example, is not compatible with an S7-1500 rack, and ET 200SP peripheral modules require a matched interface module for the network protocol in use. Confirm the full module part number, controller series, and rack slot requirements from the installed system's documentation before ordering.
Warranty: All PLC module hardware purchased from PLC Direct carries a standard 1-year PLC Direct warranty covering defects and functionality, applicable to surplus sealed, refurbished, and used products.
PLC Direct supplies PLC module hardware for replacement and maintenance purposes and does not provide system design, programming, or integration services.