Overload Relays

1026 products

Showing 649 - 672 of 1026 products

Showing 649 - 672 of 1026 products
View
Schneider New Stock Image
Schneider GV2-P14 Schneider
Sale price €119,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2L22 Schneider Electric
Schneider GV2L22 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD22 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2L
Device Application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 9 kW 400/415 V AC 50/60 Hz
11 kW 400/415 V AC 50/60 Hz
11 kW 500 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 690 V AC 50/60 Hz
Breaking capacity 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
20 kA Icu 440 V AC 50/60 Hz IEC 60947-2
10 kA Icu 500 V AC 50/60 Hz IEC 60947-2
4 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
50 % 400/415 V AC 50/60 Hz IEC 60947-2
75 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 25 A
Magnetic tripping current 388.3 A
[Ith] conventional free air thermal current 25 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 1.8 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 2 x M4 screws)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.8 in (97 mm)
Product Weight 0.73 lb(US) (0.33 kg)
color Dark grey
GVAE1 Schneider Electric
Schneider GVAE1 Schneider Electric
Sale price €68,95
Only 9 units left

TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO or 1NC instantaneous auxiliary contacts depending on the mounting orientation of the block. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on front side of the circuit breaker, connection by screw clamp terminals. Sold in lots of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Device short name GVAE
Product or Component Type Auxiliary contact block
Product Compatibility GV2L
GV2P
GV2RT
GV3P
GV3L
GV2LE
GV2ME
Mounting Location Front side
Pole contact composition 1 NO/NC
Quantity per Set Set of 10

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 300 V UL 508
300 V CSA C22.2 No 14
250 V IEC 60947-1
[Ue] rated operational voltage 24...240 V AC
24...60 V DC
[Ith] conventional free air thermal current 2.5 A
Mechanical durability 100000 cycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Protection type GG fuse 10 A
GB2CB06 circuit breaker 10 A
Rated operational power in VA 120 VA 110…120 V AC-15 100000 cycles
120 VA 230…240 V AC-15 100000 cycles
48 VA 24 V AC-15 100000 cycles
60 VA 48 V AC-15 100000 cycles
Rated operational power in W 15 W 48 V DC-13 100000 cycles
24 W 24 V DC-13 100000 cycles
9 W 60 V DC-13 100000 cycles
Tightening torque 12.4 lbf.in (1.4 N.m) screw clamp terminals
Height 0.4 in (11 mm)
Width 1.8 in (45 mm)
Depth 1.1 in (29 mm)
Product Weight 0.04 lb(US) (0.02 kg)
Schneider New Stock Image
Schneider GV2PM08C Schneider
Sale price €88,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAPL01 Schneider Electric
Schneider GVAPL01 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Handle mounting tool
Device short name GVAP
Accessory / separate part category Mounting accessory

Complementary

Characteristic Value(s)
Product Weight 0.2 lb(US) (0.1 kg)
GV4PEM50S Schneider Electric
Schneider GV4PEM50S Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PEM
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW 400...415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
15 kW 400...415 V AC 50/60 Hz
18.5 kW 400...415 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
22 kW 660...690 V AC 50/60 Hz
30 kW 660...690 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
70 kA Icu 440 V AC 50/60 Hz IEC 60947-2
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA Icu 525 V AC 50/60 Hz IEC 60947-2
100 kA 208Y/120 V AC 50/60 Hz UL 60947
100 kA 240 V AC 50/60 Hz UL 60947
65 kA 480Y/277 V AC 50/60 Hz UL 60947
10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 50 A
Magnetic tripping current 850 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles AC-3 440 V In/2
10000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
Schneider New Stock Image
Schneider LRD3359 Schneider
Sale price €93,95
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GV2PM32C Schneider
Sale price €95,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider Stock Image
Schneider GV4PB50N Schneider
Sale price €573,95
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

GV2ME106 Schneider Electric
Schneider GV2ME106 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 4-6.3 A, thermal magnetic, lugs terminals

GV7AP05 Schneider Electric
Schneider GV7AP05 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Device short name GV7AP
Product or Component Type Adaptor plate
Range compatibility TeSys TeSys GV5 motor circuit breaker
TeSys TeSys GV7 motor circuit breaker
Accessory / separate part category Mounting accessory

Complementary

Characteristic Value(s)
Mounting support Rotary handle enclosure door
IP Degree of Protection IP43
Product Weight 0.2 lb(US) (0.1 kg)
GV7AP02 Schneider Electric
Schneider GV7AP02 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV extended rotary handle, for motor circuit breakers GV5, GV6, GV7 mounted inside an enclosure and to be operated externally. For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle mechanism ensures an IP55 protection to the mounting. It also includes a mounting adaptor to be screwed on the face of the circuit breaker, and an extension shaft to be be adjusted in length (distance between the door and the back of the circuit breaker must be in range 185-600mm). Padlockable in OFF position with up to 3 padlocks (to be ordered separately).

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Extended rotary handle
Device short name GV7AP
Range compatibility TeSys TeSys GV7 motor circuit breaker
TeSys TeSys GV5 motor circuit breaker
Accessory / separate part category Control accessory
Rotary handle mounting location Front
Rotary handle mounting style Extended

Complementary

Characteristic Value(s)
Handle colour Red
Handle front plate colour Yellow
Back/door distance 7.3…23.6 in (185…600 mm)
Rotary handle padlocking 1 to 3 padlocks 0.2…0.3 in (5…8 mm)
Padlock in OFF position
Product Weight 1.709 lb(US) (0.775 kg)
GVAS225 Schneider Electric
Schneider GVAS225 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV electrical trip, MX shunt release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Product or Component Type Shunt trip release
Device short name GVAS

Complementary

Characteristic Value(s)
Range compatibility TeSys GV2ME
TeSys GV2LE
TeSys GV2L
TeSys GV2P
TeSys GV3L
TeSys GV3P
TeSys Deca
[Uc] control circuit voltage 220...240 V AC 50 Hz
Control circuit voltage limits 0.7...1.1 Un
[Ui] rated insulation voltage 690 V AC IEC 60947-1
600 V AC UL 60947-4-1
600 V AC CSA C22.2 No 60947-4-1
Threshold tripping voltage 0.75...0.2 Un
Inrush power in VA 14 VA AC
Inrush power in W 10.5 W
Hold-in Power Consumption in VA 5 VA AC
Hold-in power consumption in W 1.6 W
Operating time 10...15 ms IEC 60947-1
On-load factor 100 %
Connections - terminals screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 2 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
Tightening torque < 1.4 N.m screw clamp terminals
Mechanical durability 10000 cycles with GV3P and GV3L
30000 cycles with GV2ME and GV2P
Quantity per Set Set of 10
Height 3.5 in (89 mm)
Width 0.7 in (18 mm)
Depth 2.6 in (66 mm)
Product Weight 0.231 lb(US) (0.105 kg)
color Dark grey
GV4LE25N6 Schneider Electric
Schneider GV4LE25N6 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 25 A
Magnetic tripping current 150…350 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connection pitch 27 mm without spreaders
35 mm with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 116 mm
Product weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
GVAED011 Schneider Electric
Schneider GVAED011 Schneider Electric
Sale price€0,00
Sold Out

TeSys Deca auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, On-delay setting range 10-180s Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Sustainability compliant.

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Device short name GVAED
Product or component type Auxiliary contact block
Product compatibility GV3P
GV3L
Mounting location Front side
Auxiliary contacts operation Fault signal 1 NO
Pole contact composition 1 NO + 1 NC
Quantity per set Set of 1

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 600 V conforming to UL 508
690 V conforming to IEC 60947-1
600 V conforming to CSA C22.2 No 14
[Ue] rated operational voltage 24...240 V AC
24...60 V DC
[Ith] conventional free air thermal current 2.5 A
Mechanical durability 100000 cycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Protection type GB2CB... circuit breaker
GG fuse 10 A
Rated operational power in VA 300 VA at 48 V AC-15 - electrical durability: 100000 cycles
400 VA at 690 V AC-15 - electrical durability: 100000 cycles
500 VA at 110…127 V AC-15 - electrical durability: 100000 cycles
500 VA at 500 V AC-15 - electrical durability: 100000 cycles
650 VA at 440 V AC-15 - electrical durability: 100000 cycles
720 VA at 230…240 V AC-15 - electrical durability: 100000 cycles
850 VA at 380…415 V AC-15 - electrical durability: 100000 cycles
Rated operational power in W 120 W at 240 V DC-13 - electrical durability: 100000 cycles
140 W at 110 V DC-13 - electrical durability: 100000 cycles
140 W at 24 V DC-13 - electrical durability: 100000 cycles
180 W at 60 V DC-13 - electrical durability: 100000 cycles
240 W at 48 V DC-13 - electrical durability: 100000 cycles
Tightening torque 1.4 N.m - on screw clamp terminals
Height 11 mm
Width 45 mm
Depth 29 mm
Product weight 0.05 kg
GV2ME14C Schneider
Schneider GV2ME14C Schneider
Sale price €86,95
In stock, 12 units

TeSys Deca motor thermal magnetic circuit breaker GV2ME, push button (control), thermal outlet range: 6-10 A, screw clamp terminals

GV4L50N6 Schneider Electric
Schneider GV4L50N6 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW at 400...415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
15 kW at 400...415 V AC 50/60 Hz
18.5 kW at 400...415 V AC 50/60 Hz
22 kW at 400...415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
22 kW at 660...690 V AC 50/60 Hz
30 kW at 660...690 V AC 50/60 Hz
37 kW at 660...690 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control type Rotary handle
[In] rated current 50 A
Magnetic tripping current 300…700 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles for AC-3 at 440 V In/2
10000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connection pitch 27 mm without spreaders
35 mm with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 165 mm
Product weight 1.65 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
Schneider New Stock Image
Schneider GV2-ME10C Schneider
Sale price €87,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GV3P73GVAN11 Schneider
Sale price €154,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
LR9F5369_Schneider
Schneider LR9F5369 Schneider
Sale price €612,95
Only 6 units left

TeSys LR9F electronic overload relay, thermal setting range 90-150A, class 10, for protection of motors 55-75kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F115, F150, F185, use of a support mounting plate LA7F901 is recommended (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustment dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach).

Main

Characteristic Value(s)
Range TeSys
product name TeSys LRF
Device short name LR9F
Product or Component Type Electronic thermal overload relay
Relay application Motor protection
Product Compatibility LC1F115...LC1F185
Network type AC
Thermal overload class Class 10 IEC 60947-4
Thermal protection adjustment range 90…150 A

Complementary

Characteristic Value(s)
Network Frequency 50/60 Hz
Mounting support Direct on contactor
Plate
Tripping threshold 1.12 +/- 0.06 In tripping IEC 60947-4-1
Surge withstand 4 kV IEC 61000-4-5
Contacts type and composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A control circuit
[Ue] rated operational voltage 1000 V AC 50/60 Hz power circuit VDE 0110 group C
[Ui] rated insulation voltage Power circuit 1000 V AC IEC 60947-4
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-1
Phase failure sensitivity Tripping in 4 s +/- 20 % IEC 60947-4-1
Reset Manual reset on front relay
Control type Dial White full-load current adjustment
Test button Red
Push-button Red reset
Push-button stop
Local signalling Trip indicator
Temperature compensation -4…158 °F (-20…70 °C)
Current consumption <= 5 mA no-load
switching capacity for alarm 0...150 mA
Maximum voltage drop <2.5 V closed state
Connections - terminals Control circuit screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²) flexible - with cable end
Control circuit screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²) solid
Control circuit screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²) flexible - without cable end
Control circuit screw clamp terminals 2 0.002…0.002 in² (1…1.5 mm²) flexible - with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible - without cable end
Control circuit screw clamp terminals 2 0.002 in² (1 mm²) solid
Power circuit lugs-ring terminals M8
Tightening torque Control circuit 1.2 N.m screw clamp terminals
Power circuit 18 N.m screw clamp terminals
Height 3.8 in (96 mm)
Width 4.5 in (115 mm)
Depth 4.9 in (123.5 mm)
Product Weight 1.951 lb(US) (0.885 kg)
GV3L406 Schneider Electric
Schneider GV3L406 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV3, 3P, 40 A, magnetic, rotary handle, lugs terminals

Schneider New Stock Image
Schneider GV2ME21C Schneider
Sale price €95,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV4PEM25B6 Schneider Electric
Schneider GV4PEM25B6 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, lugs terminals

GV1F03 Schneider Electric
Schneider GV1F03 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV products provide efficient motor control and protection solutions up to 520 amps. This 7.5 mm compensation plate allows the mounting of GV2M and GV2P on a common bus bar. This plate is 1.54 inches tall, 1.38 inches wide and 0.51 inches deep.

Main

Characteristic Value(s)
Range of Product TeSys GV2
TeSys Deca
Range TeSys
Device short name GV1F
Product or Component Type Compensation plate
Accessory / separate part category Mounting accessory

Complementary

Characteristic Value(s)
Height 1.5 in (39 mm)
Width 1.4 in (35 mm)
Depth 0.5 in (13 mm)
Product Weight 0.007 lb(US) (0.003 kg)
Quantity per Set Set of 10

Recently viewed