Specifications
Model |
FU-49U*1 |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Minimum bend radius |
R2 mm0.079" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F (No freezing) |
||
Weight |
Approx. 4 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
FP-1010 |
|||
Type |
Head |
|||
Marking method |
XY scanning method |
|||
Marking style |
Strobe/continuous (constant/encoder) |
|||
Marking laser |
YVO4 laser (Class 4 laser product; IEC/EN 60825-1, JIS C6802, FDA (CDRH) Part 1040.10) |
|||
Marking laser |
Wavelength |
355 nm |
||
Output at focal point |
1.3 W (fixed at 40 kHz) |
|||
Marking area |
120 × 120 mm 4.72" × 4.72" |
|||
Maximum line speed |
4000 mm/s 157.48"/s (240 m/min 787.4'/min) |
|||
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji) |
|||
Barcode |
CODE39, CODE93, CODE128, ITF, 2of5, NW7 (CODABAR), JAN, EAN, UPC-A, UPC-E, GS1 DataBar |
|||
2D code |
QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix) |
|||
Logo |
CAD (DXF) data |
|||
No. of job registrations |
2000 |
|||
No. of program blocks |
64 |
|||
Data memory |
USB memory device *1 |
|||
Working distance |
0 to 20 mm 0.79" |
|||
Marking resolution |
2 μm 0.08 Mil |
|||
Scan speed |
5000 mm/s 196.85"/s |
|||
Interface |
Terminal block I/O, RS-232C, USB 2.0, Ethernet *1 |
|||
Label Management System |
NiceLabel 10 Version 10.X or later / NiceLabel Cloud Version 10.X or later |
|||
Head installation direction |
All directions |
|||
On-the-fly marking |
Bi-directional |
|||
Head cable length |
5 m 16.4', 10 m 32.8' |
|||
Overvoltage category |
II |
|||
Pollution degree |
2 |
|||
Cooling method |
Forced air cooling |
|||
Rated voltage and power consumption |
Single-phase 100 to 240 VAC ±10%, 50/60 Hz, 300 VA max., 130 VA standby |
|||
Environmental resistance |
Ambient temperature for transport/storage |
-10 to +60°C 14°F to 140°F (no condensation) |
||
Ambient humidity for transport/storage |
10 to 90% (no condensation) |
|||
Ambient temperature |
0 to +40°C 32°F to 104°F |
|||
Relative humidity |
10 to 90% (no condensation) |
|||
Enclosure rating |
IP65 |
|||
Weight |
13.2 kg 29.10 lb |
|||
*1 The USB port is compatible with USB memory devices and barcode readers (A connector). The Ethernet port is compatible with TCP/IP communication. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-42224 |
|||
Type |
MIL 34-pin slim connector set |
|||
Overview |
Set that includes slim type housing, hood cover, and contacts (40 units) for the AWG22 to 24. |
|||
Applicable product |
KV-C32*/C64*/SC20V |
|||
Note |
Includes 40 standard contact units |
|||

Specifications
Model |
FW-B02 |
|||
Type |
Straight Mounting Bracket |
|||
Applicable product |
FW Series |
|||
Material |
PPS |
|||

Specifications
Model |
MD-F5220 |
|||
Type |
Marking unit (Controller + Head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: Fiber laser (Class 4 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*1, GB7247.1) |
||
Wavelength |
1090 nm |
|||
Output |
50 W |
|||
Applicable regulations |
EU directive (EMC directive, machinery directive, RoHS directive), |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, Wavelength: 655 nm, Output: 1.0 mW |
|||
Marking area |
300 × 300 × 42 mm 11.81" × 11.81" × 1.65" |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm 0.20 Mil |
|||
Scan speed |
Max. 8000 mm/s 314.96"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), User fonts, True Type fonts |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E, CODE93 |
|||
2D code |
QR code, Micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, |
|||
Logo image |
Custom character font and logo CAD data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary/moving marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 300 mm 0.004" to 11.81" |
|||
No. of registered programs |
Max. 2000 programs |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*2 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.0 m 13.1' |
|||
Cooling method |
Controller: Forced air cooling, Head: Natural air cooling |
|||
Rated voltage and power consumption |
Single-phase 100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, Max. 750 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 25.5 kg |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. | ||||


Specifications
Model |
GL-VX01 |
|||
Type |
X-shaped connector for IO-Link |
|||
Number included |
1 pc. |
|||
Material |
PVC/Nickel-plated brass |
|||
Weight |
50 g |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
ER-M08FN |
|||
Type |
Compact all-metal shielded type Thin type t = 4.7 mm Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
N.O. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
50 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
9 × 9 mm 0.35" × 0.35" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less, Max. 50 mA |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
910 mW or less (38 mA or less at 24 V, 57 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Head |
SUS316L, PBT |
||
Amplifier |
Header-to-amplifier cable: TPU, Case: PBT/TPU |
|||
Accessories |
― |
|||
Accessories | ||||
Weight |
Approx. 65 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||



Specifications
Model |
F-1*1 |
|||
Type |
Side view |
|||
Compatible fiber |
FU-77V/77 ,FU-77G ,FU-7F/86A ,FU-86Z ,FU-78/84C/88K |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F*2 |
||
Weight |
Approx. 2 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
OP-33158 |
|||
Type |
Reducer Replacement Joint |
|||
Applicable product |
AP-41, AP-43, AP-44 |
|||
Cable end |
M5 female thread and ø6 mm on respective side |
|||

Specifications
Model |
SZ-P30NM |
|||
Type |
Output Cable, NPN |
|||
Applicable product |
SZ-04M, SZ-16V |
|||
Length |
30 m 98.42' |
|||
Weight |
Approx. 2,080 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CA-LH25P |
|||
Focal point |
25 mm 0.98" |
|||
F-stop range (aperture) |
F1.4/4/8/16*1 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Filter size |
27.0 mm 1.06" P0.5 |
|||
Mount |
C-mount |
|||
Max. compatible image sensor size |
2/3" |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
TV distortion |
-0.04% |
|||
Enclosure rating |
IP64 (objective lens, water repellent coating specifications)*3 |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 75 g |
|||
*1 The f-stop (aperture) is changed by replacing the diaphragm plate. When this product is shipped, the OPEN diaphragm plate is attached to the lens, so replace it with one of the other included diaphragm plates (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EG-545U |
|||
Type |
AC adj-dial |
|||
Sensitivity adjustment |
10-turn potentiometer dial |
|||
Function |
Operation mode |
N.O./N.C. switch-selectable |
||
Operation mode |
External synchronization |
Equipment (contact output only) |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
SPDT, 250 VAC, 2 A max. (resistive load) |
|||
Disconnection alarm output |
― |
|||
Response |
1 ms |
|||
10 ms | ||||
OFF-delay time |
65 ms (contact output only) |
|||
Temperature characteristics |
0.08%/°C*1 |
|||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 350 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||