Machine Vision Systems

5768 products

Showing 1033 - 1056 of 5768 products

Showing 1033 - 1056 of 5768 products
View
keyence Stock Image
Keyence CA-LML0210 Keyence
Sale price€0,00
Sold Out

Specifications

Model

CA-LML0210*1

Optical magnification

x0.25 to x1.0

WD (at reference magnification)

×0.25

238 mm 9.37"*2

×0.50

137 mm 5.39"*2

×0.75

105 mm 4.13"*2

×1.0

88 mm 3.46"*2

Compatible image sensor size

2"

Field of view (at reference magnification)

1": 9.6 x 12.8 mm to 38.4 x 51.2 mm 0.38" x 0.50" to 1.51" x 2.01", 28.7 mm 1.13" line camera: 28.7 mm to 114.7 mm 1.13" to 4.52",
2": 19.2 x 25.6 mm to 76.8 x 102.4 mm0.76" x 1.01" to 3.02" x 4.03"

F-stop range (aperture)

F6 to F64 (F-stop: F2.8 to F32)

Telecentricity

-

Filter size

46.0 mm P0.75 1.81"

Resolution

×0.25

16.8 µm 0.66 Mil*3

×0.50

8.4 µm 0.33 Mil*3

×1.0

4.2 µm 0.17 Mil*3

TV distortion (Max.)

×0.25

-0.10 %

×0.50

0.10 %

×1.0

-0.10 %

Depth-of-field

×0.25

20.48 mm 0.81"*4

×0.50

5.12 mm 0.20"*4

×1.0

1.28 mm 0.05"*4

Mount

Special mount (M40 P0.75)

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

80% RH or less (No condensation)

Weight

Approx. 650 g

*1 When installing the macro lens (CA-LMxx) to the line scan camera, make sure to secure the lens unit with the dedicated mounting stand (OP-87337, sold separately) or an equivalent mount.
*2 WD indicates a working distance at reference magnification. WD will vary depending on magnification adjustment.
*3 The smallest resolvable feature that can be detected using 550 nm wavelength light.
*4 Depth-of-field applies to an F-stop of 16 and will vary depending on F-stop setting. The indicated depth-of-field is a theoretical value that assumes 1/2" image sensor size and a horizontal resolution of 320 lines. (Circle of least confusion is 40 µm 1.57 Mil in the image)

keyence Stock Image
Keyence CA-DPB2 Keyence
Sale price €445,95
Only 2 units left

Specifications

Model

CA-DPB2

Type

Spot Light

LED color

Blue

Power consumption

8.4 W (2.0 W)*1

Input voltage

12 VDC

Weight

Approx. 20 g

*1 The power consumption specification indicates the total consumption (CA-DP spot + CA-DP power adapter). The specification in parenthesis is just for the CA-DP spot light.

keyence Stock Image
Keyence OP-87949 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87949

Type

Probe cable for replacement

Applicable product

XM-1000, XM-T1000, XM-1200, XM-T1200

keyence Stock Image
Keyence MP-FCBC20 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-42284 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence XG-7502 Keyence
Sale price €5.739,95
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence KV-H40S Keyence
Sale price €263,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence GL-R47F Keyence
Sale price €1.041,95
Only 10 units left

Specifications

Model

GL-R47F

Detection capability

ø0.55" ø14 mm

Total length

18.90" 480mm

No. of beam

47

Detection height

18.11" 460mm

Protection height

19.06" 484mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

9.5

OFF→ON

53.1*2

All blocked→ON

74.8*3

Optical synchronization system
(Channel A or B)

ON→OFF

13.5

OFF→ON

59*2

All blocked→ON

90.7*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

60

Receiver

74

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

660 g

Receiver

670 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

keyence Stock Image
Keyence GL-VM71FN Keyence
Sale price€0,00
Sold Out

Specifications

Model

GL-VM71FN

Beam axis spacing/Lens diameter

10 mm 0.39": ø4 ø0.16"

Number of beam axes

71

Total length

720 mm 28.35"

Detection height

700 mm 27.56"

Protection height

724 mm 28.50"

Minimum detectable object size

ø14 mm ø0.55" *1

Detecting distance

0.3 to 12 m 1.0' to 39.4' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

6.8

OFF→ON

51.8 *3

All blocked→ON

61.3 *4

With channel A or B

ON→OFF

20.9

OFF→ON

77.6 *3

All blocked→ON

107.2 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

105 *5

Receiver

116 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

60 *5

Receiver

65 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

480 g 16.94 oz

Receiver

Total

960 g 33.88 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence OP-84397 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-84397

Applicable product

GT2

keyence Stock Image
Keyence FU-86A Keyence
Sale price €283,95
Only 1 unit left

Specifications

Model

FU-86A*1

Optical axis diameter
(Standard target to be detected)

ø1 mm0.039"

Heat resistant temperature

105°C 221°F*2*3

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø2.2

Minimum bend radius

R25 mm0.984"

Minimum detectable object

Object with a diameter of 0.005 mm0.0002"*4

Environmental resistance

Ambient temperature

-40 to +105 °C -40 to 221 °F

Weight

Approx. 22 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 When this product is used in an environment with a consistently high temperature, we recommend an ambient usage temperature of 90°C or less.
*3 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature.
*4 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

Keyence Stock Image
Keyence OP-88656 Keyence
Sale price €210,95
Only 7 units left

Specifications

Model

OP-88656

Type

12-pin power supply cable

Length

10 m 32.8'

Weight

Approx. 610 g

Keyence Stock Image
Keyence KV-E4XRDC Keyence
Sale price€0,00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence CA-DRM10DA Keyence
Sale price€0,00
Sold Out

Specifications

Model

CA-DRM10DA

Type

100 mm 3.94" type

keyence Stock Image
Keyence CL-PT010G Keyence
Sale price€0,00
Sold Out

Specifications

Model

CL-PT010G

Type

Optical unit

Head

CL-PT010 *1

Reference distance

10 mm 0.39"

Reference measurement range

Measurement range

±0.3 mm ±0.01"

Linearity

±0.11 μm ±0.000004" *2

High precision measurement range

Measurement range

±0.15 mm ±0.01"

Linearity

±0.09 μm ±0.000004" *3

Resolution

0.001 μm *4

Spot diameter

ø3.5 μm ø0.000138"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP64 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

0 to 50°C 32 to 122°F

Optical unit

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

None

Explosion-proof

performance

Head

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.1% of F.S./°C *5

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 1100 g 2.43 lb

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*4 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*5 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence OP-89068 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence LV-H67 Keyence
Sale price €306,95
In stock, 15 units

Specifications

Model

LV-H67

Type

High power

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

20 m 65.6'

TURBO

30 m 98.4'

SUPER

30 m *1 98.4'

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Material

Case

Glass reinforced plastic

Lens cover

Transparent plastic *2

Reflective mirror

ABS plastic, Acrylic

Weight

Approx. 45 g

*1 The detecting distance is 50 m 164.0' when OP-42198 is used.
*2 Norbornene plastic or acrylic

Keyence Stock Image
Keyence GL-R127F-T Keyence
Sale price €1.532,95
Only 4 units left

Specifications

Model

GL-R127F

Detection capability

ø0.55" ø14 mm

Total length

50.39" 1280mm

No. of beam

127

Detection height

49.61" 1260mm

Protection height

50.55" 1284mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

18.1

OFF→ON

66*2

All blocked→ON

109.4*3

Optical synchronization system
(Channel A or B)

ON→OFF

27.4

OFF→ON

79.9*2

All blocked→ON

146.4*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

78

Receiver

89

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1800 g

Receiver

1900 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Keyence Stock Image
Keyence KV-E8R Keyence
Sale price €330,95
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-88865 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88865

Diameter

0.55" 14 mm

Length

7.87" 200 mm

Material

ABS

keyence Stock Image
Keyence SV2-BE5A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SV2-BE5A

Type

Encoder cable, Standard cable with battery

Length

5 m 16.4'

Note

for 1 k to 5 kW motor

keyence Stock Image
Keyence CL-L070 Keyence
Sale price €6.587,95
Only 5 units left

Specifications

Model

CL-L070 *1

Type

Sensor head (70 mm ・Quad type)

*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit.

keyence Stock Image
Keyence OP-89084 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88625 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.