Specifications
Model |
CA-LML0210*1 |
|||
Optical magnification |
x0.25 to x1.0 |
|||
WD (at reference magnification) |
×0.25 |
238 mm 9.37"*2 |
||
×0.50 |
137 mm 5.39"*2 |
|||
×0.75 |
105 mm 4.13"*2 |
|||
×1.0 |
88 mm 3.46"*2 |
|||
Compatible image sensor size |
2" |
|||
Field of view (at reference magnification) |
1": 9.6 x 12.8 mm to 38.4 x 51.2 mm 0.38" x 0.50" to 1.51" x 2.01", 28.7 mm 1.13" line camera: 28.7 mm to 114.7 mm 1.13" to 4.52", |
|||
F-stop range (aperture) |
F6 to F64 (F-stop: F2.8 to F32) |
|||
Telecentricity |
- |
|||
Filter size |
46.0 mm P0.75 1.81" |
|||
Resolution |
×0.25 |
16.8 µm 0.66 Mil*3 |
||
×0.50 |
8.4 µm 0.33 Mil*3 |
|||
×1.0 |
4.2 µm 0.17 Mil*3 |
|||
TV distortion (Max.) |
×0.25 |
-0.10 % |
||
×0.50 |
0.10 % |
|||
×1.0 |
-0.10 % |
|||
Depth-of-field |
×0.25 |
20.48 mm 0.81"*4 |
||
×0.50 |
5.12 mm 0.20"*4 |
|||
×1.0 |
1.28 mm 0.05"*4 |
|||
Mount |
Special mount (M40 P0.75) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
80% RH or less (No condensation) |
|||
Weight |
Approx. 650 g |
|||
*1 When installing the macro lens (CA-LMxx) to the line scan camera, make sure to secure the lens unit with the dedicated mounting stand (OP-87337, sold separately) or an equivalent mount. | ||||

Specifications
Model |
CA-DPB2 |
|||
Type |
Spot Light |
|||
LED color |
Blue |
|||
Power consumption |
8.4 W (2.0 W)*1 |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 20 g |
|||
*1 The power consumption specification indicates the total consumption (CA-DP spot + CA-DP power adapter). The specification in parenthesis is just for the CA-DP spot light. | ||||

Specifications
Model |
OP-87949 |
|||
Type |
Probe cable for replacement |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
GL-R47F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
18.90" 480mm |
|||
No. of beam |
47 |
|||
Detection height |
18.11" 460mm |
|||
Protection height |
19.06" 484mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
9.5 |
|
OFF→ON |
53.1*2 |
|||
All blocked→ON |
74.8*3 |
|||
Optical synchronization system |
ON→OFF |
13.5 |
||
OFF→ON |
59*2 |
|||
All blocked→ON |
90.7*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
60 |
||
Receiver |
74 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
660 g |
||
Receiver |
670 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
GL-VM71FN |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
71 |
|||
Total length |
720 mm 28.35" |
|||
Detection height |
700 mm 27.56" |
|||
Protection height |
724 mm 28.50" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
6.8 |
|
OFF→ON |
51.8 *3 |
|||
All blocked→ON |
61.3 *4 |
|||
With channel A or B |
ON→OFF |
20.9 |
||
OFF→ON |
77.6 *3 |
|||
All blocked→ON |
107.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
105 *5 |
||
Receiver |
116 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
60 *5 |
||
Receiver |
65 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
480 g 16.94 oz |
||
Receiver | ||||
Total |
960 g 33.88 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
FU-86A*1 |
|||
Optical axis diameter |
ø1 mm0.039" |
|||
Heat resistant temperature |
105°C 221°F*2*3 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Object with a diameter of 0.005 mm0.0002"*4 |
|||
Environmental resistance |
Ambient temperature |
-40 to +105 °C -40 to 221 °F |
||
Weight |
Approx. 22 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CL-PT010G |
|||
Type |
Optical unit |
|||
Head |
CL-PT010 *1 |
|||
Reference distance |
10 mm 0.39" |
|||
Reference measurement range |
Measurement range |
±0.3 mm ±0.01" |
||
Linearity |
±0.11 μm ±0.000004" *2 |
|||
High precision measurement range |
Measurement range |
±0.15 mm ±0.01" |
||
Linearity |
±0.09 μm ±0.000004" *3 |
|||
Resolution |
0.001 μm *4 |
|||
Spot diameter |
ø3.5 μm ø0.000138" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP64 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
0 to 50°C 32 to 122°F |
||
Optical unit | ||||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
None |
|||
Explosion-proof |
performance |
Head |
||
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.1% of F.S./°C *5 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 1100 g 2.43 lb |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||


Specifications
Model |
LV-H67 |
|||
Type |
High power |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
20 m 65.6' |
||
TURBO |
30 m 98.4' |
|||
SUPER |
30 m *1 98.4' |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transparent plastic *2 |
|||
Reflective mirror |
ABS plastic, Acrylic |
|||
Weight |
Approx. 45 g |
|||
*1 The detecting distance is 50 m 164.0' when OP-42198 is used. | ||||

Specifications
Model |
GL-R127F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
50.39" 1280mm |
|||
No. of beam |
127 |
|||
Detection height |
49.61" 1260mm |
|||
Protection height |
50.55" 1284mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
18.1 |
|
OFF→ON |
66*2 |
|||
All blocked→ON |
109.4*3 |
|||
Optical synchronization system |
ON→OFF |
27.4 |
||
OFF→ON |
79.9*2 |
|||
All blocked→ON |
146.4*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
78 |
||
Receiver |
89 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1800 g |
||
Receiver |
1900 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-BE5A |
|||
Type |
Encoder cable, Standard cable with battery |
|||
Length |
5 m 16.4' |
|||
Note |
for 1 k to 5 kW motor |
|||

Specifications
Model |
CL-L070 *1 |
|||
Type |
Sensor head (70 mm ・Quad type) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||