Specifications
Model |
GL-VM28HP |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
28 |
|||
Total length |
560 mm 22.05" |
|||
Detection height |
540 mm 21.26" |
|||
Protection height |
585 mm 23.03" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
5.0 |
|
OFF→ON |
48.6 *3 |
|||
All blocked→ON |
55.4 *4 |
|||
With channel A or B |
ON→OFF |
13.7 |
||
OFF→ON |
60.8 *3 |
|||
All blocked→ON |
79.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
87 *5 |
||
Receiver |
98 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
53 *5 |
||
Receiver |
59 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
370 g 13.06 oz |
||
Receiver |
380 g 13.41 oz |
|||
Total |
750 g 26.47 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CL-L015N |
|||
Type |
Optical unit |
|||
Head |
CL-L015 *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.49 μm ±0.000019" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.41 μm ±0.000016" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø300 μm ø0.0118" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 180 g 6.35 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
FS-N41P |
|||
Type |
Cable |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
1 |
|||
Number of external inputs |
― |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*3 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4 |
||
Power consumption |
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 78 g |
|||
*1 Restrictions when S-HSPD is selected | ||||

Specifications
Model |
OP-73880 |
|||
Overview |
Fixing bracket to fix DIN amplifier. |
|||
Applicable product |
FS-V30/FS-N10/LV-N10/PS-N10 Series |
|||
Material |
Polycarbonate |
|||

Specifications
Model |
OP-84388 |
|||
Overview |
Relay substrate unit for the replacement of dedicated SL-T11R for the relay terminal SL-V. |
|||
Applicable product |
SL-T11R |
|||

Specifications
Model |
CB-B3*1 |
|||
Type |
Head cable |
|||
Cable min. bending R |
22 mm 0.87" |
|||
Cable length |
3 m 9.84' |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529)*2 |
||
Material |
PVC |
|||
Weight |
Approx. 250 g |
|||
*1 Regarding cable extension between the head and controller: Up to 2 cables can be connected with the CB-BxxE, and these cables should be kept to a total length of 30 m 98.4' or less. | ||||

Specifications
Model |
FD-XC8R3 |
|||
Supported diameter |
Outer diameter of pipe: ø 8 0.31 " |
|||
Weight |
Approx. 60 g |
|||


Specifications
Model |
FW-H10R |
|||
Type |
Long range |
|||
Detecting area |
150 to 1000 mm 5.9" to 39.4"*1 |
|||
Response speed |
1,000 ms |
|||
Temperature characteristics |
0.06% of F.S./°C*2 |
|||
Indicator lamp |
Operation indicator (orange) x1 (Turns on when the target is within the detecting range.) |
|||
Dimensions |
M18 x P1, Length= 104 mm 4.09" |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Brass-nickel plating, PBT, Polyurethane, Polyamide resin |
|||
Accessories |
M18 nut: 2, Head cable: 2 m 6.6', Standard Mounting Bracket (FW-B01) |
|||
Weight |
Approx. 106 g |
|||
*1 Less stable zones of approx. 2% of F.S. exist at both ends of the detecting range. | ||||

Specifications
Model |
GL-R1UB |
|||
Type |
Interface Unit |
|||
Overview |
Optional accessory that is necessary for performing GL-R settings and monitoring with a PC. |
|||
Applicable product |
GL-R Series |
|||
Number included |
1 unit |
|||
Material |
Polycarbonate |
|||
Note |
The USB cable to use in connecting the interface unit and a PC is not included. Use an A to miniB type USB cable (sold separately). |
|||
Weight |
Approx. 10 g |
|||

Specifications
Model |
NQ-MP8L |
|||
Network Specifications |
Compatible Networks |
EtherNet/IP™, PROFINET, Modbus/TCP |
||
Communication Speed |
10 Mbps/100 Mbps |
|||
Connector |
M12 4-pin female D-code |
|||
Power Supply Specifications |
Connector Type |
Power supply port IN: M12 5-pin male L-code |
||
Power Voltage |
18 to 30 VDC |
|||
Allowable Current |
V1 and V2: max. 9 A each |
|||
Current Consumption |
V1: max. 180 mA |
|||
Sensor Connection Specifications |
Connector Type |
M12 5-pin female A-code |
||
V1 Power Supply Capacity |
Ports 1 and 5: Each port max. 4 A, with short-circuit protection |
|||
V2 Power Supply Capacity |
Ports 5 and 6: Each port max. 4 A, with short-circuit protection |
|||
IO-Link Specifications |
Number of Connectable Devices |
8 |
||
Compliant Standards |
Ver1.1 |
|||
Transmission Speed |
COM1: 4.8 kbps |
|||
Port type |
Ports 1 to 4: Class A |
|||
Process Data Size |
Input: Max. 32 bytes/Output: Max. 32 bytes |
|||
Digital Input (DI) Specifications |
Number of Inputs |
Max. 12 (when using DI mode) |
||
Input Type |
PNP |
|||
ON Voltage/ON Current |
11 V or higher/2 mA or higher |
|||
OFF Voltage/OFF Current |
Less than 5 V/less than 1.5 mA |
|||
Input Current |
Pin 2: approx. 7 mA, Pin 4: approx. 12 mA |
|||
Digital Output (DO) Specifications |
Number of Outputs |
Max. 4 |
||
Output Type |
PNP |
|||
Maximum Load Current |
Each port max. 2 A |
|||
Short-Circuit Protection Circuit |
Yes |
|||
Leakage Current |
0.1 mA or lower |
|||
Residual Voltage |
1 V or lower |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67/IP69K |
||
Ambient temperature |
-40°C to +70°C -40°F to +158°F (no freezing) |
|||
Vibration resistance |
5 to 150 Hz/20 G/10 sweeps each in X, Y, and Z axes |
|||
Shock resistance |
15 G/11 ms/3 times each in X, Y, and Z axes |
|||
Case Material |
Housing: PA6-GF30 |
|||
Weight |
Approx. 530 g 18.69 oz |
|||
*1 When using Class B, V1 and V2 each require a power supply. | ||||

Specifications
Model |
SZ-04M |
|||
Type |
Multi-function type |
|||
Detection |
Minimum detectable object size |
Diameter 30 mm 1.18"/40 mm 1.58", 50 mm 1.97", 70 mm 2.76", 150 mm 5.91" (depends on the setting) |
||
Detectable angle |
270° (-45° to 225°) |
|||
Response time |
General scan cycle (Scan cycle A) |
60 ms (2 scans) to 480 ms (16 scans) |
||
Specific scan cycle (Scan cycle B) |
66 ms (2 scans) to 528 ms (16 scans) |
|||
Response time |
General scan cycle (Scan cycle A) |
Response time of ON to OFF +125 ms |
||
Specific scan cycle (Scan cycle B) | ||||
Max. |
Minimum detectable object size: 70 mm 2.76"/150 mm 5.91" |
4.2 m 13.78' (-5° to 185°), 2.8 m 9.19' (-45° to -5°, 185° to 225°) |
||
Minimum detectable object size: 50 mm 1.97" |
3.0 m 9.84' (-5° to 185°), 2.0 m 6.56' (-45° to -5°, 185° to 225°) |
|||
Minimum detectable object size: 40 mm 1.58" |
2.4 m 7.87' (-5° to 185°), 1.6 m 5.25' (-45° to -5°, 185° to 225°) |
|||
Minimum detectable object size: 30 mm 1.18" |
1.8 m 5.91' (-5° to 185°), 1.2 m 3.94' (-45° to -5°, 185° to 225°) |
|||
Max. |
Minimum detectable object size: 70 mm 2.76"/150 mm 5.91" |
10.0 m 32.18' (-5° to 185°), 7.0 m 22.97' (-45° to -5°, 185° to 225°)*1 |
||
Minimum detectable object size: 50 mm 1.97" |
7.5 m 24.61' (-5° to 185°), 5.0 m 16.4' (-45° to -5°, 185° to 225°)*1 |
|||
Minimum detectable object size: 40 mm 1.58" |
6.0 m 19.69' (-5° to 185°), 4.0 m 13.12' (-45° to -5°, 185° to 225°)*1 |
|||
Minimum detectable object size: 30 mm 1.18" |
4.5 m 14.76' (-5° to 185°), 3.0 m 9.84' (-45° to -5°, 185° to 225°)*1 |
|||
Additional safety distance |
100 mm 3.94"*2 |
|||
Light source |
Type, wavelength |
Infrared laser diode, 905 nm |
||
Laser class |
Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10 *3) |
|||
OSSD output |
Output |
PNP or NPN (Selectable according to the connector cable) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF-state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 1 mA*5 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100Ω) |
|||
Load wiring resistance |
Max. 2.5Ω*6 |
|||
Input |
Input resistance |
4.4 kΩ (for Input 1, 3, 4, and 5) |
||
Non |
Output |
PNP/NPN totem pole output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
Muting lamp |
(AUX6 output can be assigned for the |
Can be connected to the |
||
Cable length |
30 m 98.43' or less *7 |
|||
Approved |
EMC |
EMS |
IEC61496-1, EN61496-1, UL 61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR) |
|||
Rating |
Power voltage |
When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Max. 9.5 W (without load) |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529)*8 |
||
Ambient light |
Incandescent lamp: 1,500 lux or less*9 |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
35 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum die casting, SPHC (Bottom) |
||
Window |
Polycarbonate |
|||
Weight |
Approx. 1.6 kg |
|||
*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone. | ||||

Specifications
Model |
GS-71P5 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 560 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
FU-69X*1 |
|||
Size |
M3 |
|||
Fibre unit length |
1 m39.37" cannot be cut |
|||
Minimum bend radius |
R4 mm0.157" high-flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 3 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
GS-10PC |
|||
Type |
Simple function type |
|||
Operating distance |
Front |
Sao(OFF→ON) |
10 mm 0.39" |
|
Sar(ON→OFF) |
18 mm 0.71" |
|||
Side |
Sao(OFF→ON) |
6 mm 0.24" |
||
Sar(ON→OFF) |
14 mm 0.55" |
|||
Response time |
Detection |
Detect→Not detect |
20 ms + 2 ms × (number of units cascaded -1)*1 |
|
Not detect→Detect |
30 ms + 25 ms × (number of units cascaded -1)*1 |
|||
Door operation |
Acceptable operation frequency |
3 Hz |
||
Cascading |
Standard |
- |
||
Using Y-shaped connector | ||||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 500 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max.2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
- |
||
Reset/EDM input | ||||
Applicable Standards (Safety) |
EN 61508, IEC 61508 (SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
0.8 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) |
||
Operating ambient temperature |
-20°C to +55°C -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*2 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
Zinc die cast (Nickel chrome plating), PBT, PAR |
|
Cable |
PVC |
|||
Actuator |
Case |
SUS430, SUS304, PBT |
||
Weight |
Approx. 80 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
GS-ML51P |
|||
Type |
For sliding door M12 Connector Standard |
|||
Holding force when locked |
500N |
|||
Holding force when unlocked |
Approx. 30N *1 |
|||
Cascading |
Max. 20 units |
|||
Operating distance |
Sao(OFF→ON) |
0.1 mm 0.004" *2 |
||
Sar(ON → OFF) |
15 mm 0.59" *2 |
|||
Response time (ms) |
Lock→Unlock |
250 ms *3 |
||
Unlock→Lock | ||||
Detect→ Not detect |
20 ms + 2 ms × (number of cascaded unit -1) *3 |
|||
Not detect→ Detect |
300 ms + 25 ms × (number of cascaded unit -1) *3 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
150 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
0.8 μF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V(with a cable of 5 m 16.4') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
Approx. 5 mA |
|||
Lock control input |
Approx. 2.5 mA |
|||
OSSD operation switching input |
Approx. 2.5 mA |
|||
Applicable Standards (Safety) |
EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4), |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10% or less, Class2) |
||
Power consumption |
5 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Operating ambient temperature |
-20 to 55°C -4 to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25 to 70°C -13 to 158°F(No freezing) *4 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis |
|||
Material |
Main unit |
PBT, PET/PAR, TPC, PC, Nickel-plated steel |
||
Actuator |
PBT, SUS304, Nickel-plated steel |
|||
Mounting bracket |
Aluminum, Painted steel (screw: Steel) |
|||
Weight |
Main unit |
Approx.240 g |
||
Actuator |
Approx.130 g 4.59 oz |
|||
*1 When the actuator is pulled first after unlocked, the holding force increases. | ||||

Specifications
Model |
GC-S1R |
|||
Input/output points |
Safety inputs |
- |
||
Safety outputs | ||||
Safety relay output |
1 (3a) |
|||
AUX outputs |
- |
|||
Test outputs | ||||
Safety input specifications |
Input device |
|||
Input type | ||||
ON level (voltage/current) | ||||
OFF level (voltage/current) | ||||
Short-circuit current | ||||
Protection circuit | ||||
Maximum cable length | ||||
Safety output specifications |
Output type |
|||
Maximum load current | ||||
Residual voltage (during ON) | ||||
Leakage current (during OFF) | ||||
Maximum capacitive load | ||||
Load wiring resistance | ||||
Protection circuit | ||||
Maximum cable length | ||||
Safety relay output specifications |
Output type |
Relay (3a) (Externally-protected outputs)*1 |
||
Rated load (resistance load) |
250 VAC 6A / 30 VDC 6A*2 |
|||
Rated load (inductive load) |
240 VAC 2A (AC-15) / 24 VDC 1A (DC-13) |
|||
Relay output mechanical life |
Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
B10d |
With rated load: 400,000 |
|||
Test output specifications |
Output type |
- |
||
Maximum load current | ||||
Protection circuit | ||||
Maximum cable length | ||||
AUX output specifications |
Output type |
|||
Maximum load current | ||||
Residual voltage (during ON) | ||||
Leakage current (during OFF) | ||||
Protection circuit | ||||
Maximum cable length | ||||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A |
||
Safety |
IEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998 |
|||
Dimensions |
39.6×95×90 mm 1.56"×3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
- |
||
Power consumption |
Max. 80 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II (III for relay output part) |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 180 g |
|||
*1 To comply with the requirements of IEC61131-2, connect 10 A fast blow fuse (IEC 60217) in series to each contact. | ||||



Specifications
Model |
IV2-CP50 |
|||
Supported languages |
English / Japanese / German / Chinese (Simplified) /Chinese (Traditional) / Korean / |
|||
Display |
5.7" TFT color LCD, 640 × 480 (VGA) |
|||
Backlight |
Method |
White LED |
||
Duration |
Approx. 50000 hours (25°C 77°F) |
|||
Touch panel |
Method |
Analog resistive |
||
Actuating force |
0.8 N or less |
|||
Indicators |
PWR, SENSOR |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*2 |
||
Connector |
M12 4-pin connector*2 |
|||
Expanded memory |
USB memory*3 |
|||
Rating |
Power voltage |
24 VDC ±10% (including ripple) |
||
Current consumption |
0.3 A or less |
|||
Environmental resistance |
Enclosure rating |
IP40 |
||
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Relative humidity |
35 to 85% RH (No condensation) *4 |
|||
Drop resistance |
1.3 m 4.3' onto concrete (2 times in an arbitrary direction) |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 0.7 mm 0.03"; 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit case: PC, Power connector: Brass + Ni plating, Ethernet connector: Zinc + Ni plating / PA, |
|||
Weight |
Main unit: Approx. 450 g |
|||
*1 When connected to the IV2 Series. When connected to the IV Series, the supported languages are the same as the IV-M30. | ||||

Specifications
Model |
FU-44TZ*1 |
|||
Beam emitting direction |
Top |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R2 mm0.079" Tough-Flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 3 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
FU-10 |
|||
Type |
Variable spot |
|||
Focal distance |
10 to 30 mm0.394" to 1.181" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.3×2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||

Specifications
Model |
FD-G50 |
|||
Pipe size |
DN (Diameter Nominal) |
32 A, 40 A, 50 A |
||
NPS (Nominal Pipe Size) |
1 1/4", 1 1/2", 2" |
|||
Outer diameter of pipe |
ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44" |
|||
Pipe thickness |
2.4 to 5.7 mm 0.09" to 0.22" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 32 A: 54.00 |
||
L/min |
Pipe size 32 A: 900.0 |
|||
CFM |
Pipe size 32 A: 32.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 32 A: 151.58 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 32 A: 192.17 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 32 A: 232.76 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 32 A: 273.35 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.01 CFM |
||
Consumption/leakage amount |
0.01 m3, 1 L, 0.1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.7 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||