Specifications
Model |
IV-HG10 |
|||
Type |
Main unit |
|||
Tools |
Type |
Shape Detection, Color Area*1, Area*2, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment), OCR*3 |
||
Number |
Detection tools: 16 tools, position adjustment tool: 1 tool*4 |
|||
Switch settings (programs) |
32 programs |
|||
Image history |
Numbers |
When using a color type head: 100 images*5, when using a monochrome type head: 300 images*6*7 |
||
Condition |
NG only/All is selectable*7 |
|||
Analysis information |
OFF/Statistics/Histograms/Matching rate list is switchable |
|||
Other functions |
HDR, HighGain, Color filters*1, Digital zoom (2x, 4x)*9, Brightness correction, Tilt correction, White balance*1, Mask function, Color histogram, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Direct connection (2 units or more), Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold |
|||
Indicators |
PWR/ERR, OUT, TRIG, STATUS, LINK/ACT |
|||
Input |
Type |
Non-voltage input/voltage input is switchable |
||
Inputs |
6 inputs (IN1 to IN6) |
|||
Function |
IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions |
|||
Output |
Type |
Open collector output NPN/PNP is switchable, N.O./N.C. is switchable |
||
Outputs |
8 outputs (OUT1 to OUT8) |
|||
Function |
Enable by assigning the optional functions |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*10 |
||
Connector |
RJ-45 8pin connector*10 |
|||
Network function |
FTP client, EtherNet/IP™, PROFINET |
|||
Rating |
Power voltage |
24 VDC ±10 % (including ripple) |
||
Current consumption |
0.8 A or less. 1.5 A or less when also using an expansion unit (IV-HG15). (The output load is excluded.) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing)*11 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case: Polycarbonate |
|||
Weight |
Approx. 150 g |
|||
*1 Color type only | ||||

Specifications
Model |
ES-M1P*1 |
|||
Type |
One-line expansion system |
|||
Shape |
Main unit |
|||
Operation mode |
N.O./N.C. switch-selectable |
|||
Timer function |
10-ms delay / timer OFF switchable*2 |
|||
Output |
PNP |
|||
Output |
Control output |
PNPopen collector 100 mA max. 26.4 V, residual voltage 1 V max. |
||
Disconnection alarm output |
PNPopen collector 100 mA max. |
|||
Response time |
1 ms max. |
|||
Temperature characteristics |
Within ±8% of detecting distance at +23°C 73.4°F when within 0 to 50°C 32 to 122°F temperature range |
|||
Sensitivity adjustment |
25-turn trimmer |
|||
Protection circuit |
Reverse power connection protection, output overcurrent protection, output surge protection |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current/power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 65 g (including nuts and 2-m 9.8' cable) |
|||
*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290. | ||||

Specifications
Model |
GS-51PC |
|||
Lock type |
Power-to-release type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
OP-73864 |
|||
Type |
Connector Cable |
|||
Applicable product |
FS-N1*C, FS-V30C, PZ-G, M8 connector sensor |
|||
Number included |
1 pcs. |
|||
Cable end |
M8 straight - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Weight |
Approx. 55 g |
|||

Specifications
Model |
GS-11PC |
|||
Type |
Standard type |
|||
Operating distance |
Front |
Sao(OFF→ON) |
10 mm 0.39" |
|
Sar(ON→OFF) |
18 mm 0.71" |
|||
Side |
Sao(OFF→ON) |
6 mm 0.24" |
||
Sar(ON→OFF) |
14 mm 0.55" |
|||
Response time |
Detection |
Detect→Not detect |
20 ms + 2 ms × (number of units cascaded -1)*1 |
|
Not detect→Detect |
30 ms + 25 ms × (number of units cascaded -1)*1 |
|||
Door operation |
Acceptable operation frequency |
3 Hz |
||
Cascading |
Standard |
Max. 30 units |
||
Using Y-shaped connector |
Max. 4 units*2 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 500 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max.2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508 (SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
0.8 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) |
||
Operating ambient temperature |
-20°C to +55°C -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*3 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
Zinc die cast (Nickel chrome plating), PBT, PAR |
|
Cable |
PVC |
|||
Actuator |
Case |
SUS430, SUS304, PBT |
||
Weight |
Approx. 80 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
GS-71PC |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
LV-H62 |
|||
Type |
Small beam spot |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
2 m 6.6' |
||
TURBO |
5 m 16.4' |
|||
SUPER |
7 m 23.0' |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transparent plastic *1 |
|||
Reflective mirror |
Polycarbonate, acrylic |
|||
Weight |
Approx. 45 g |
|||
*1 Norbornene plastic or acrylic | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FS-N13N |
|||
Type |
High functionality 2 output |
|||
Output |
NPN |
|||
Main unit/expansion unit |
Main unit |
|||
Control output |
2 |
|||
Monitor output (1-5 V) |
- |
|||
External input |
1 |
|||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C -4 to +131 °F (No freezing)*2 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 80 g |
|||
*1 Increases 100 mW (4.0 mA) for High Speed mode | ||||

Specifications
Model |
SZ-V04 *1 |
|||
Type |
Multi-function Type |
|||
Detection capability |
Minimum detectable object size |
Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2 |
||
Detectable angle |
190° ( -5° to 185° ) |
|||
Response time (ON to OFF) |
Standard Mode |
Scan Cycle A |
160 ms (2scans) to 1280 ms (16scans) *3 *4 |
|
Scan Cycle B |
168 ms (2scans) to 1344 ms (16scans) *3 *4 |
|||
Scan Cycle C |
176 ms (2scans) to 1408 ms (16scans) *3 *4 |
|||
High Speed Mode |
Scan Cycle A |
80 ms (2scans) to 640 ms (16scans) *3 *4 |
||
Scan Cycle B |
84 ms (2scans) to 672 ms (16scans) *3 *4 |
|||
Scan Cycle C |
88 ms (2scans) to 704 ms (16scans) *3 *4 |
|||
Response time (OFF to ON) |
Response time (ON to OFF) + 150 ms |
|||
Protection zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode) |
||
Minimum detectable object size: 50 mm 1.97" |
5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode) |
|||
Minimum detectable object size: 40 mm 1.57" |
4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode) |
|||
Minimum detectable object size: 30 mm 1.18" |
2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode) |
|||
Minimum detectable object size: 20 mm 0.79" |
1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode) |
|||
Warning zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5 |
||
Minimum detectable object size: 50 mm 1.97" |
25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5 |
|||
Minimum detectable object size: 40 mm 1.57" |
24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5 |
|||
Minimum detectable object size: 30 mm 1.18" |
23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5 |
|||
Minimum detectable object size: 20 mm 0.79" |
21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5 |
|||
Additional safety distance |
100 mm 3.94" *6 |
|||
Maximum measurement distance |
60 m 196.85' *7 |
|||
Maximum number of banks |
Max. 4 banks |
|||
Multiple scanner heads |
Max. 3 scanner heads |
|||
Camera monitoring area |
Monitor area: over 190° (-5° to 185°) *8 |
|||
Display |
QVGA 2.2inch color LCD |
|||
Light source |
Type, wavelength |
Infrared laser diode, 905 nm |
||
Laser Class |
IEC |
Class1 IEC/EN60825-1 |
||
FDA |
Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice) *9 |
|||
JIS |
Class1 JIS C6802 |
|||
Control output (OSSD) |
Output |
Transistor outputs (NPN or PNP is selected in the software) |
||
Number of outputs |
4 outputs |
|||
Max. load current |
500 mA *10 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF-state voltage |
Max. 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 1 mA *11 |
|||
Max. capacitive load |
2.2 μF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs |
PNP |
ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) |
||
NPN |
ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) |
|||
Non-safety related output (AUX output) |
Output type |
Transistor outputs (NPN or PNP is selected by the dedicated PC software) |
||
Number of outputs |
6 outputs |
|||
Max. load current |
Max. 50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.40') |
|||
Muting lamp |
Incandescent lamp (24 VDC, 1 to 5.5 W) or LED lamp (load current: 10 to 230 mA) can be connected |
|||
Interface |
USB |
USB2.0 |
||
Ethernet |
Standard |
- |
||
Transmission rate | ||||
Cable | ||||
Connector | ||||
Network function | ||||
Cable length |
Power and I/O cable |
30 m 98.43' or less *12 |
||
Between scanner head and display unitc |
20 m 65.62' or less each *13 |
|||
Ethernet cable |
- |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE) |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508, |
|||
Rating |
Power consumption |
11.8 W (without load), 55.0 W (with load) *14 |
||
Power voltage |
24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery |
|||
Environmental resistance |
Enclosure rating |
IP65(IEC60529) |
||
Ambient light |
Incandescent lamp: 1500 lux or less *15 |
|||
Operating ambient temperature |
-10 to +50°C 14 to 122°F (No freezing) |
|||
Operating relative humidity |
35% to 85% RH (No condensation) |
|||
Storage temperature |
-25 to +60°C -13 to +140°F (No freezing) |
|||
Storage relative humidity |
35% to 95% RH |
|||
Vibration resistance |
10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis |
|||
Material |
Scanner head |
Main unit case |
Magnesium |
|
Window |
Polycarbonate, PEI |
|||
Indicator part |
Aluminum, PES |
|||
Display unit |
Case |
Magnesium, PPS, Polycarbonate |
||
System memory |
Aluminum, PPE |
|||
Weight |
Approx. 2100 g |
|||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). | ||||

Specifications
Model |
OP-84327 |
|||
Type |
Head mounting bracket |
|||
Applicable product |
GT2-H32/GT2-H50 |
|||
Note |
Sold separately |
|||

Specifications
Model |
FS-N12CP |
|||
Type |
Standard 1 output |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Expansion unit |
|||
Control output |
1 |
|||
External input |
1 |
|||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*2 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C -4 to +131 °F (No freezing)*3 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 22 g |
|||
*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types. | ||||

Specifications
Model |
FU-35FG*1 |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Fibre unit diameter |
ø1.3×2 |
|||
Shape |
Straight |
|||
Minimum bend radius |
R10 mm0.394" , stainless |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 15 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-21X*1 |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
50 cm19.685" cannot be cut |
|||
Shape |
Straight |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 4 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
FD-Q50C |
|||
Supported pipe diameter |
1 1/2" (40 A), ø44 to ø52 (mm) |
|||
Supported pipe materials |
Metal pipe/Resin pipe*1 |
|||
Supported fluids |
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 |
|||
Supported fluid temperature |
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2 |
|||
Maximum rated flow |
1 1/2" (40 A): 400 L/min, 105.7 G/min |
|||
Zero cut flow rate |
25 L/min (Default)*3 |
|||
Display method |
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
0.1/ 1 (Default :1) (L/min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, |
|||
Repeatability |
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time)) |
|||
Hysteresis |
Variable |
|||
Integrated flow unit display |
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) |
|||
Integrated flow data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
|||
Power I/O connector |
M12 4-pin connector |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), |
||
Analog output (ch.2) |
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 |
|||
External input (ch.2) |
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), |
|||
Power supply |
Power voltage |
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
||
Current consumption |
130 mA or less (Load current excluded)*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Sensor main unit |
PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
||
Sensor surface |
Rubber |
|||
Mounting bracket |
SUS304/PA/POM/SUSXM7 |
|||
Weight |
Approx. 640 g (including mounting bracket) |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) | ||||

Specifications
Model |
FT-H20 |
|||
Type |
Mid to low temperature, Mid-range |
|||
Rated temperature range |
32 to 932°F (0 to 500°C) *1 |
|||
Displayable temperature range |
-58 to +968°F (-50 to +520°C) |
|||
Detecting distance |
Unlimited *2 |
|||
Measuring distance / |
60/ø8.5 mm 2.36"/ø0.33" |
|||
Sight |
2-point visible laser beam *3 |
|||
Detecting element |
Thermopile |
|||
Detecting wavelength |
8 to 14 μm |
|||
Repeatability |
±0.9°F (±0.5°C) |
|||
Emissivity (ε) correction |
0.10 to 1.99 (0.01 step) |
|||
Environmental resistance |
Ambient temperature |
14 to 131°F (-10 to 55°C), No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions |
|||
Shock resistance |
500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total |
|||
Material |
Case: Reinforced glass plastic, |
|||
Accessory |
Mounting bracket |
|||
Weight |
Approx. 120g |
|||
*1 Repeatability is guaranteed within the rated temperature range. | ||||

Specifications
Model |
FU-E11 |
|||
Type |
Area thrubeam |
|||
No. of beam axes |
11 × 2 mm0.433" × 0.079", 11 × 1 mm0.433" × 0.039" (when the 1.0 mm0.039" slit is attached), 11 × 0.5 mm0.433" × 0.02" (when the 0.5 mm0.02" slit is attached) |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R2 mm0.079" |
|||
Minimum detectable object |
Opaque material with a diameter of 0.2 mm0.008"*1 |
|||
Tightening torque |
0.15 Nm |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit case : polybutylene terephthalate, screw mounting seat : SUS304, lens : norbornene plastic, core fiber : acrylic, fiber sheath : polyethylene |
|||
Accessories |
Mounting screws (M2 × 6), nuts (M2, t = 1.2), fiber cutter, slit (0.5 mm or 1.0 mm width) |
|||
Weight |
Approx. 20 g |
|||
*1 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state. | ||||

Specifications
Model |
LV-NH100 |
|||
Type |
Area thrubeam, High performance |
|||
FDA (CDRH) Part 1040.10 |
Class 1 Laser Product |
|||
IEC 60825-1 | ||||
Light source |
Visible red semiconductor laser, Wavelength: 660 nm |
|||
Detecting |
MEGA |
2000 mm 78.74" |
||
ULTRA | ||||
SUPER | ||||
TURBO | ||||
FINE | ||||
HSP | ||||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transmitter: Glass, Receiver: Polyarylate |
|||
Weight |
Approx. 75 g |
|||

Specifications
Model |
GS-M51P |
|||
Type |
For hinged door Small M12 Connector Standard |
|||
Holding force when locked |
500N |
|||
Holding force when unlocked |
Approx. 30N *1 |
|||
Cascading |
Max. 20 units |
|||
Operating distance |
Sao(OFF→ON) |
0.1 mm 0.004" *2 |
||
Sar(ON → OFF) |
15 mm 0.59" *2 |
|||
Response time (ms) |
Lock→Unlock |
250 ms *3 |
||
Unlock→Lock | ||||
Detect→ Not detect |
20 ms + 2 ms × (number of cascaded unit -1) *3 |
|||
Not detect→ Detect |
300 ms + 25 ms × (number of cascaded unit -1) *3 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
150 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
0.8 μF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V(with a cable of 5 m 16.4') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
Approx. 5 mA |
|||
Lock control input |
Approx. 2.5 mA |
|||
OSSD operation switching input |
Approx. 2.5 mA |
|||
Applicable Standards (Safety) |
EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4), |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10% or less, Class2) |
||
Power consumption |
5 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Operating ambient temperature |
-20 to 55°C -4 to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25 to 70°C -13 to 158°F(No freezing) *4 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis |
|||
Material |
Main unit |
PBT, PET/PAR, TPC, PC, Nickel-plated steel |
||
Actuator |
PBT, SUS304, Nickel-plated steel |
|||
Mounting bracket |
Aluminum (Plate and screw: Steel) |
|||
Weight |
Main unit |
Approx.250 g |
||
Actuator |
Approx.160 g 5.64 oz |
|||
*1 When the actuator is pulled first after unlocked, the holding force increases. | ||||

Specifications
Model |
OP-87057 |
|||
Type |
Sensor head cable |
|||
Applicable product |
IL,IG,GV-T Series head |
|||
Cable end |
M8 straight - e-con |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Note |
The cable is common to the transmitter and receiver sides, and can be used on either of them. |
|||
Weight |
Approx. 190 g |
|||