Specifications
Model |
OP-87638 |
|||
Number included |
1 |
|||
Cable end |
M12 L-shaped - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: PVCConnector: Zinc nickel plating |
|||
Weight |
Approx. 90 g |
|||






Specifications
Model |
FU-R67TZ*1 |
|||
Type |
Threaded and Hex-Shaped Active Receiver Fibers |
|||
Size |
M6 |
|||
Fibre unit length |
2 m6.6'Free-cut |
|||
Fibre unit diameter |
ø 2.2ø 0.09" x 2 |
|||
Shape |
Hex-shaped |
|||
Minimum bend radius |
R2 mmR0.08"ToughFlex |
|||
Environmental resistance |
Ambient temperature |
−40 to +60 ˚C -40 to +140 °F |
||
Weight |
Approx. 25 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
FW-LG01*1 |
|||
Rating |
Power voltage |
6 VDC (button battery LR43 x 4) |
||
Light source |
Blue LED (wavelength: 470 nm) |
|||
Environmental resistance |
Ambient temperature |
0 to +45 °C 32 to 113 °F (No freezing) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Main unit: ABS; Keycap: Silicon rubber |
|||
Accessories |
Test button batteries (LR43): 4, instruction manual |
|||
Weight |
Approx. 21 g (Including batteries) |
|||
*1 It is recommended that the product be used with a maximum detecting distance of 500 mm | ||||

Specifications
Model |
GS-P5CC5 |
|||
Type |
For extension/Simple function type (5-pin) |
|||
Length |
5 m 16.40' |
|||
Weight |
Approx. 310 g |
|||

Specifications
Model |
FD-XC8M |
|||
Supported diameter |
Attachable range: ø 5.5 to 8.3 mm 0.22 " to 0.33 " |
|||
Weight |
Approx. 210 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
XC-T20B1 |
|||
Rated voltage |
125 VAC/DC |
|||
Rated current |
1 A/pin |
|||
Ambient operating temperature |
−40 to +80°C −40 to +176°F |
|||
Screw torque |
0.8 N·m (max.) |
|||
Applicable wire diameter |
AWG22 to 16 |
|||
Environmental resistance |
Insulation resistance |
500 VDC, 1000 MΩ or greater |
||
Withstand voltage |
500 VAC, 1 minute, 1 mA or less |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-H63F |
|||
Type |
Hose model |
|||
Supported pipe diameter |
ø48–63 ø1.89"-2.48" |
|||
Supported pipe materials |
Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1 |
|||
Supported fluids |
All fluids (water, oil, chemicals, etc.)*1 |
|||
Supported fluid temperature |
0–100°C 32–212°F (no freezing on pipe surface)*2 |
|||
Maximum rated flow |
500 L/min |
|||
Zero cut flow rate |
5.0 L/min |
|||
Detection principle |
Delta TOF |
|||
Function for automatic correction for speed of sound in liquid |
— |
|||
Display |
QVGA 2.0 model: color LCD, status indicator light |
|||
Display update cycle |
Approx. 10 times/second |
|||
Display resolution |
Instantaneous flow |
0.01/0.1/1 (L/min) (default value: 1) |
||
Integrated flow |
0.01/0.1/1 (L) (default value: 1; up to 8 digits) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
|||
Measurement accuracy |
— |
|||
Repeatability |
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4 |
|||
Hysteresis |
Variable |
|||
Flow units |
L/min m3/h G/min |
|||
Pulse output increments (L) |
0.02–999.99 |
|||
Pipe temperature measurement accuracy |
— |
|||
Network support |
IO-Link*5 |
|||
Heat calculation function |
Unit |
MJ/h kW kBTU/h*6 |
||
Display resolution |
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6 |
|||
Pulse output increments (MJ) |
0.02–999.99*6 |
|||
Data accumulation |
Accumulation period |
Approx. 1 year |
||
Data reading |
USB2.0 |
|||
Power I/O connector |
M12 8-pin connector (male) |
|||
I/O (switchable) |
Output (Ch1/2/3/4) |
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output |
||
Analog output (Ch1/2) |
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
|||
External input (Ch2/3) |
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input |
|||
Power supply |
Power voltage |
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
||
Current consumption |
240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7 |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output short circuits, and output surges |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*8 |
||
Ambient temperature |
Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2 |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes |
|||
Material |
Display unit |
Body: PPS/PET/POM; Display window: PAR |
||
Sensor head |
Body: PPS/PET/PAR/SUS304; Cable: PVC |
|||
Weight |
approx. 1360 g 47.97 oz |
|||
*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe. | ||||

Specifications
Model |
OP-51457 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V39F, SL-V20H, SL-V10L, SL-C20H, SL-C10L |
|||
Number included |
1 pcs. |
|||
Length |
390.3 mm 15.37" |
|||
Material |
Translucent plastic: Polycarbonate (t=Approx. 1.8mm), Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

Specifications
Model |
MD-F5220C*1 |
|||
Type |
Marking unit (Controller + Head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: Fiber laser (Class 4 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*2, GB7247.1) |
||
Wavelength |
1090 nm |
|||
Output |
50 W |
|||
Applicable regulations |
EU directive (EMC directive, machinery directive, RoHS directive), |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, Wavelength: 655 nm, Output: 1.0 mW |
|||
Marking area |
300 × 300 × 42 mm 11.81" × 11.81" × 1.65" |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm 0.20 Mil |
|||
Scan speed |
Max. 8000 mm/s 314.96"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), User fonts, True Type fonts |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E, CODE93 |
|||
2D code |
QR code, Micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, |
|||
Logo image |
Custom character font and logo CAD data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary/moving marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 300 mm 0.004" to 11.81" |
|||
No. of registered programs |
Max. 2000 programs |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, Connector control I/O |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.0 m 13.1' |
|||
Cooling method |
Controller: Forced air cooling, Head: Natural air cooling |
|||
Rated voltage and power consumption |
Single-phase 100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, Max. 750 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 25.5 kg |
|||
*1 Type equipped with contactor control terminal block | ||||

Specifications
Model |
IV2-G150MA |
|||
Type |
Narrow field of view sensor model |
|||
Reference distance |
40 to 150 mm 1.57" to 5.91" |
|||
Field of view |
Installation distance of 40 mm 1.57": |
|||
Indicators |
2 (the same display details for both indicators) |
|||
Image receiving element |
Type |
1/3 inch monochrome CMOS |
||
Number of pixels |
752 (H) × 480 (V) |
|||
Focus adjustment |
Automatic*2 |
|||
Exposure time |
1/20 to 1/50000 |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse lighting and DC lighting |
|||
Environmental resistance |
Enclosure rating |
IP67*3 |
||
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions*4 |
|||
Shock resistance |
500 m/s2 1640.4'/s2, 6 times in each of the 3 directions*4 |
|||
Material |
Main unit case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU |
|||
Weight |
Approx. 75 g |
|||
*1 When using the magnifying lens attachment (OP-87902): 4 (H) × 3 (V) mm 0.16" (H) × 0.12" (V) (at installation distance of 18 mm 0.71") to 7 (H) × 5.2 (V) mm 0.28" (H) × 0.20" (V) (at installation distance of 27 mm 1.06") | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FL-SP100 |
|||
Total length (at 25 °C) |
1026 |
|||
Measurement range (dead zone excluded) |
964 (919)*1 |
|||
Weight |
Approx. 545 g |
|||
*1 Values for water. For oil | ||||

Specifications
Model |
IV3-L6M |
|||
Compatible sensor |
IV3-600MA |
|||
Lights |
Illumination |
Infrared LED |
||
Power supply |
Power is supplied by the connected sensor |
|||
Environmental resistance |
Enclosure rating |
IP67 *1 |
||
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Relative humidity |
35 to 85%RH (No condensation) |
|||
Material |
Case: Aluminum die-casting |
|||
Weight |
Approx. 195 g 6.88 oz |
|||
*1 Applicable only when mounted to a compatible sensor. Except when the polarizing filter (OP-88644/OP-88645/OP-88646/OP-88647) is mounted. | ||||

Specifications
Model |
OP-88071 |
|||
Type |
Cable for Separate Amplifier Models: For Amplifier (Connector Type) |
|||
Overview |
This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector sensor |
|||
Cable end |
M8 - M12 straight |
|||
Length |
2 m 6.6' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 70 g 2.46 oz |
|||

Specifications
Model |
KV-XH16EC |
|||
Type |
Positioning/motion unit |
|||
No. of control axes |
16 axes (including virtual axes) |
|||
Appropriated device |
Relay: 2112 points (132 channels) |
|||
Output format |
EtherCAT ® |
|||
Connectable CPU unit |
KV-X Series/KV-8000A |
|||
Max. number of connectable units |
15 |
|||
Refresh |
Automatic refresh, direct refresh, synchronous refresh between units |
|||
Control mode |
Position control, torque control, speed control, I/O control |
|||
Control period |
125 μs or more |
|||
Starting time |
125 μs |
|||
Axis control function execution method |
Ladder program, unit program (flow) |
|||
Unit program capacity |
3 MB (Max. number of blocks: 20000) |
|||
Flow |
Block type |
Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block |
||
flow |
Max. number of flows |
256 |
||
Number of simultaneous activities |
No upper limit |
|||
Flow |
Internal data Memory |
524288 words |
||
Position unit |
mm, inch, deg (angle), PLS (number of pulses); Decimal point position from 0 to 9 digits, unit conversion function available |
|||
Cumulative address |
-2147483648 to +2147483647 specification units |
|||
Positioning control |
Positioning mode |
Absolute value/relative value |
||
Position setting range |
-2147483648 to +2147483647 specification units |
|||
Interpolation |
Linear interpolation, arc interpolation, helical interpolation |
|||
Single operation address |
-2147483648 to +2147483647 specification units |
|||
Acceleration/deceleration curve |
Linear, SIN |
|||
Acceleration/deceleration time |
0 to 65535 ms |
|||
M-code |
1 to 65000, WITH/AFTER mode |
|||
Sensor positioning |
External input-based switching control from speed to position |
|||
Special function |
Synchronous tracking control, absolute position tracking control |
|||
Synchronization control |
Input |
External reference, instruction coordinates, current coordinates |
||
Input filter |
Interference prevention function |
|||
Clutch |
Select from direct, slide, and follow-up |
|||
Cam |
Resolution: 2048 to 32768, Data points: 4 to 64 (changes according to the resolution) |
|||
Compensation during operation |
Compensation via auxiliary input, phase compensation, and step angle compensation |
|||
Origin return |
Origin return method |
Data set type, dog type (push), dog type (selectable from “with Z phase” or “without Z phase”), |
||
JOG/inching |
JOG (high speed/low speed), inching (specifiable pulses) |
|||
Teaching |
Current coordinate teaching |
|||
Memory data |
Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters, |
|||
Output display |
LINK/ACT, CONNECT, error status |
|||
Self-diagnosis function |
Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages |
|||
Parameter setting |
Parameters can be set from KV STUDIO, ladder programs, and unit programs |
|||
Data backup |
Coordinates: nonvolatile memory backup (unlimited), Parameter settings: flash ROM backup (20000 switches) |
|||
Internal current consumption |
160 mA or less |
|||
Weight |
Approx. 190 g |
|||