Machine Vision Systems

5768 products

Showing 4513 - 4536 of 5768 products

Showing 4513 - 4536 of 5768 products
View
keyence Stock Image
Keyence OP-87986 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87638 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87638

Number included

1

Cable end

M12 L-shaped - Loose wire

Length

2 m 6.56'

Material

Cable: PVCConnector: Zinc nickel plating

Weight

Approx. 90 g

keyence Stock Image
Keyence OP-42184 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CA-F100 Keyence
Sale price €523,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence FD-V70A Keyence
Sale price €1.772,95
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence OP-87231 Keyence
Sale price €167,95
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-89044 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence FU-R67TZ Keyence
Sale price €130,95
Only 7 units left

Specifications

Model

FU-R67TZ*1

Type

Threaded and Hex-Shaped Active Receiver Fibers

Size

M6

Fibre unit length

2 m6.6'Free-cut

Fibre unit diameter

ø 2.2ø 0.09" x 2

Shape

Hex-shaped

Minimum bend radius

R2 mmR0.08"ToughFlex

Environmental resistance

Ambient temperature

−40 to +60 ˚C -40 to +140 °F

Weight

Approx. 25 g

*1 For details on the detecting distance, see the fiber amplifier catalog.

keyence Stock Image
Keyence FW-LG01 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FW-LG01*1

Rating

Power voltage

6 VDC (button battery LR43 x 4)

Light source

Blue LED (wavelength: 470 nm)

Environmental resistance

Ambient temperature

0 to +45 °C 32 to 113 °F (No freezing)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Main unit: ABS; Keycap: Silicon rubber

Accessories

Test button batteries (LR43): 4, instruction manual
Batteries are loaded to the casing.

Weight

Approx. 21 g (Including batteries)

*1 It is recommended that the product be used with a maximum detecting distance of 500 mm
19.69" due to the visibility and consistency of the spot and the detecting distance.

keyence Stock Image
Keyence GS-P5CC5 Keyence
Sale price €318,95
Only 2 units left

Specifications

Model

GS-P5CC5

Type

For extension/Simple function type (5-pin)

Length

5 m 16.40'

Weight

Approx. 310 g

keyence Stock Image
Keyence OP-88652 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88652

Type

M12/M12 Ethernet cable

Length

5 m 16.4'

Weight

Approx. 330 g

keyence Stock Image
Keyence FD-XC8M Keyence
Sale price €544,95
Only 5 units left

Specifications

Model

FD-XC8M

Supported diameter

Attachable range: ø 5.5 to 8.3 mm 0.22 " to 0.33 "

Weight

Approx. 210 g

Keyence Stock Image
Keyence KV-DA40V Keyence
Sale price €796,95
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence XC-T20B1 Keyence
Sale price€0,00
Sold Out

Specifications

Model

XC-T20B1

Rated voltage

125 VAC/DC

Rated current

1 A/pin

Ambient operating temperature

−40 to +80°C −40 to +176°F

Screw torque

0.8 N·m (max.)

Applicable wire diameter

AWG22 to 16

Environmental resistance

Insulation resistance

500 VDC, 1000 MΩ or greater

Withstand voltage

500 VAC, 1 minute, 1 mA or less

Keyence Stock Image
Keyence KV-16ATP Keyence
Sale price €999,95
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence FD-H63F Keyence
Sale price €1.222,95
Only 3 units left

Specifications

Model

FD-H63F

Type

Hose model

Supported pipe diameter

ø48–63 ø1.89"-2.48"

Supported pipe materials

Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1

Supported fluids

All fluids (water, oil, chemicals, etc.)*1

Supported fluid temperature

0–100°C 32–212°F (no freezing on pipe surface)*2

Maximum rated flow

500 L/min
132.1 gal/min

Zero cut flow rate

5.0 L/min
1.3 gal/min (variable, initial value)

Detection principle

Delta TOF

Function for automatic correction for speed of sound in liquid

Display

QVGA 2.0 model: color LCD, status indicator light

Display update cycle

Approx. 10 times/second

Display resolution

Instantaneous flow

0.01/0.1/1 (L/min) (default value: 1)

Integrated flow

0.01/0.1/1 (L) (default value: 1; up to 8 digits)

Response time

0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s

Measurement accuracy

Repeatability

0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4

Hysteresis

Variable

Flow units

L/min m3/h G/min

Pulse output increments (L)

0.02–999.99

Pipe temperature measurement accuracy

Network support

IO-Link*5

Heat calculation function

Unit

MJ/h kW kBTU/h*6

Display resolution

Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6

Pulse output increments (MJ)

0.02–999.99*6

Data accumulation

Accumulation period

Approx. 1 year

Data reading

USB2.0

Power I/O connector

M12 8-pin connector (male)

I/O (switchable)

Output (Ch1/2/3/4)

Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)

4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

External input (Ch2/3)

Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply

Power voltage

20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

Current consumption

240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*8

Ambient temperature

Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes

Material

Display unit

Body: PPS/PET/POM; Display window: PAR

Sensor head

Body: PPS/PET/PAR/SUS304; Cable: PVC
Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7

Weight

approx. 1360 g 47.97 oz

*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.
*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*6 Can be used when two temperature sensors (sold separately) are connected.
*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*8 When a USB connection is in use, IP65/67 compliance is impaired.

keyence Stock Image
Keyence OP-51457 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-51457

Overview

Front protective cover protecting detection side of light curtain.

Applicable product

SL-V39F, SL-V20H, SL-V10L, SL-C20H, SL-C10L

Number included

1 pcs.

Length

390.3 mm 15.37"

Material

Translucent plastic: Polycarbonate (t=Approx. 1.8mm), Black plastic: ABS

Note

To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42

keyence Stock Image
Keyence MD-F5220C Keyence
Sale price€0,00
Sold Out

Specifications

Model

MD-F5220C*1

Type

Marking unit (Controller + Head)
50 W, Wide area

Console (sold separately)

MC-P1

Marking method

XYZ 3-axis simultaneous scanning method

Marking laser

Type

Yb: Fiber laser (Class 4 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*2, GB7247.1)

Wavelength

1090 nm

Output

50 W

Applicable regulations

EU directive (EMC directive, machinery directive, RoHS directive),
EN standard (EN 55011, EN ISO 11553-1, EN 60204-1, EN 60825-1, EN 61000-6-2, EN 50581),
CSA and UL standards (CAN/CSA C22.2 No. 61010-1-12, UL 61010-1),
North America regulations (FCC Part 15B, ICES-001 Class A), China RoHS

Pulse frequency

60 to 120 kHz

Guide laser/Working distance pointer

Semiconductor laser, Wavelength: 655 nm, Output: 1.0 mW
(Class 2 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*2, GB7247.1)

Marking area

300 × 300 × 42 mm 11.81" × 11.81" × 1.65"

Standard working distance (±variable width)

300 mm (±21 mm) 11.81" (±0.83")

Marking resolution

5 µm 0.20 Mil

Scan speed

Max. 8000 mm/s 314.96"/s

Character type

Font

KEYENCE original font (numbers, letters, katakana, hiragana, kanji), User fonts, True Type fonts

Barcode

CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E, CODE93

2D code

QR code, Micro QR code/DataMatrix (ECC200/GS1 DataMatrix)

GS1 DataBar

GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A,
GS1 DataBar Limited, GS1 DataBar Limited CC-A, GS1 DataBar Truncated, GS1 DataBar Truncated CC-A

Logo image

Custom character font and logo CAD data, BMP/JPEG/PNG/TIFF

Marking conditions

Workpiece style

Stationary/moving marking (constant speed/encoder)

Character size (marking height/width)

0.1 to 300 mm 0.004" to 11.81"

No. of registered programs

Max. 2000 programs

No. of program blocks

256 blocks

I/O (Input/output)

Terminal block I/O, MIL connector I/O, Connector control I/O

Interface

RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*3

Head installation direction

All directions

Head cable length

4.0 m 13.1'

Cooling method

Controller: Forced air cooling, Head: Natural air cooling

Rated voltage and power consumption

Single-phase 100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, Max. 750 VA

Environmental resistance

Enclosure rating

IP64 (Head)

Pollution degree

2

Overvoltage category

II

Ambient temperature for storage

-10 to +60 °C 14 to 140 °F (No freezing)

Ambient temperature

0 to +40 °C 32 to 104 °F

Ambient humidity for storage

30 to 85 % RH (No condensation)

Relative humidity

Weight

Controller: 25.5 kg
Head: 6.7 kg
Console: 2.0 kg

*1 Type equipped with contactor control terminal block
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 The USB port is designed for use with USB memory sticks, barcode readers, mouses (A connector), and Marking Builder 3 (ActiveX) (B connector).
The Ethernet port supports communication with Marking Builder 3 (ActiveX), TCP/IP communication, PROFINET connection, and EtherNet/IP™ connection.

Keyence New Stock Image
Keyence IV2-G150MA Keyence
Sale price €646,95
In stock, 17 units

Specifications

Model

IV2-G150MA

Type

Narrow field of view sensor model

Reference distance

40 to 150 mm 1.57" to 5.91"

Field of view

Installation distance of 40 mm 1.57":
8 (H) × 6 (V) mm 0.31" (H) × 0.24" (V) to
Installation distance of 150 mm 5.91":
32 (H) × 24 (V) mm 1.26" (H) × 0.94" (V)*1

Indicators

2 (the same display details for both indicators)

Image receiving element

Type

1/3 inch monochrome CMOS

Number of pixels

752 (H) × 480 (V)

Focus adjustment

Automatic*2

Exposure time

1/20 to 1/50000

Lights

Illumination

White LED

Lighting method

Switchable between pulse lighting and DC lighting

Environmental resistance

Enclosure rating

IP67*3

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions*4

Shock resistance

500 m/s2 1640.4'/s2, 6 times in each of the 3 directions*4

Material

Main unit case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU

Weight

Approx. 75 g

*1 When using the magnifying lens attachment (OP-87902): 4 (H) × 3 (V) mm 0.16" (H) × 0.12" (V) (at installation distance of 18 mm 0.71") to 7 (H) × 5.2 (V) mm 0.28" (H) × 0.20" (V) (at installation distance of 27 mm 1.06")
*2 The focus position can be automatically adjusted at the time of installation. This function is deactivated during operation. A different focus position can be registered for each program.
*3 Except when the polarized light filter attachment (OP-87899/OP-87900/OP-87901) or the magnifying lens attachment (OP-87902) is mounted.
*4 Except when the IV2 dome attachment (IV2-GD05/IV2-GD10) is mounted.

Keyence Stock Image
Keyence VT3-V7R Keyence
Sale price €6.343,95
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence FL-SP100 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FL-SP100

Total length (at 25 °C)

1026

Measurement range (dead zone excluded)

964 (919)*1

Weight

Approx. 545 g

*1 Values for water. For oil

Keyence Stock Image
Keyence IV3-L6M Keyence
Sale price €590,95
Only 6 units left

Specifications

Model

IV3-L6M

Compatible sensor

IV3-600MA

Lights

Illumination

Infrared LED

Power supply

Power is supplied by the connected sensor

Environmental resistance

Enclosure rating

IP67 *1

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85%RH (No condensation)

Material

Case: Aluminum die-casting
Front cover: Acrylic

Weight

Approx. 195 g 6.88 oz

*1 Applicable only when mounted to a compatible sensor. Except when the polarizing filter (OP-88644/OP-88645/OP-88646/OP-88647) is mounted.

keyence Stock Image
Keyence OP-88071 Keyence
Sale price €295,95
Only 1 unit left

Specifications

Model

OP-88071

Type

Cable for Separate Amplifier Models: For Amplifier (Connector Type)

Overview

This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M8 connector sensor

Cable end

M8 - M12 straight

Length

2 m 6.6'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 70 g 2.46 oz

keyence Stock Image
Keyence KV-XH16EC Keyence
Sale price €1.577,95
Only 5 units left

Specifications

Model

KV-XH16EC

Type

Positioning/motion unit

No. of control axes

16 axes (including virtual axes)

Appropriated device

Relay: 2112 points (132 channels)
Data memory: 4 words

Output format

EtherCAT ®

Connectable CPU unit

KV-X Series/KV-8000A

Max. number of connectable units

15

Refresh

Automatic refresh, direct refresh, synchronous refresh between units

Control mode

Position control, torque control, speed control, I/O control

Control period

125 μs or more

Starting time

125 μs

Axis control function execution method

Ladder program, unit program (flow)

Unit program capacity

3 MB (Max. number of blocks: 20000)

Flow

Block type

Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block

flow

Max. number of flows

256

Number of simultaneous activities

No upper limit

Flow

Internal data Memory

524288 words

Position unit

mm, inch, deg (angle), PLS (number of pulses); Decimal point position from 0 to 9 digits, unit conversion function available

Cumulative address

-2147483648 to +2147483647 specification units

Positioning control

Positioning mode

Absolute value/relative value

Position setting range

-2147483648 to +2147483647 specification units

Interpolation

Linear interpolation, arc interpolation, helical interpolation

Single operation address

-2147483648 to +2147483647 specification units

Acceleration/deceleration curve

Linear, SIN

Acceleration/deceleration time

0 to 65535 ms

M-code

1 to 65000, WITH/AFTER mode

Sensor positioning

External input-based switching control from speed to position

Special function

Synchronous tracking control, absolute position tracking control

Synchronization control

Input

External reference, instruction coordinates, current coordinates

Input filter

Interference prevention function

Clutch

Select from direct, slide, and follow-up

Cam

Resolution: 2048 to 32768, Data points: 4 to 64 (changes according to the resolution)

Compensation during operation

Compensation via auxiliary input, phase compensation, and step angle compensation

Origin return

Origin return method

Data set type, dog type (push), dog type (selectable from “with Z phase” or “without Z phase”),
dog type sizing (selectable from “with Z phase” or “without Z phase”), immediate Z phase, origin sensor and Z phase,
rising edge of limit switch,
origin sensor midpoint/rising edge

JOG/inching

JOG (high speed/low speed), inching (specifiable pulses)

Teaching

Current coordinate teaching

Memory data

Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters,
setting read/write during RUN (with some restrictions)

Output display

LINK/ACT, CONNECT, error status

Self-diagnosis function

Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages

Parameter setting

Parameters can be set from KV STUDIO, ladder programs, and unit programs

Data backup

Coordinates: nonvolatile memory backup (unlimited), Parameter settings: flash ROM backup (20000 switches)

Internal current consumption

160 mA or less

Weight

Approx. 190 g

Recently viewed