Machine Vision Systems

5768 products

Showing 4345 - 4368 of 5768 products

Showing 4345 - 4368 of 5768 products
View
Keyence Stock Image
Keyence OP-87909 Keyence
Sale price €157,95
Only 7 units left

Specifications

Model

OP-87909

Type

Rear mounting bracket

Weight

Approx. 20 g

keyence Stock Image
Keyence OP-85139 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-85139

Overview

Polarizing filter for the red IR LED type. (Used for thrubeam models to prevent interference.)

Applicable product

PZ-G52

Number included

3 pcs.

Material

Acetate plastic

Weight

Approx. 1 g

Keyence Stock Image
Keyence EG-530 Keyence
Sale price €327,95
In stock, 15 units

Specifications

Model

EG-530

Type

DC

Sensitivity adjustment

15-turn trimmer

Function

Operation mode

N.O./N.C. (switch-selectable)

Operation mode

External synchronization

Output

Control output 1 (NPN)

100 mA max. (40 V max.) Residual voltage: 1 V max.

Control output 2

Disconnection alarm output
(NPN)

100 mA max.
(40 V max.) Residual
voltage: 1 V max.

Response
time (Relay contact)

1 ms

OFF-delay time

Temperature characteristics

0.08%/°C*1

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less

Power consumption

100 mA max.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 75 g

*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.

Keyence Stock Image
Keyence RC-14 Keyence
Sale price €714,95
Only 3 units left

Specifications

Model

RC-14

Type

1-level preset counter/timer, DC type

Operation method

Addition, subtraction

Operation mode

Overcount, auto reset

Return method

Manual reset, external reset, automatic reset (in auto reset mode)

Display power

7-segment LED (character height: 10 mm)

Number of digits

6-digit display, -99,999 to 999,999*1

Power off memory time

Approx 10 years (at 20°C 68°F)

Mounting method

Panel mount (embedding), surface mount, DIN rail mount*2

Highest counting speed

With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio)

Input signal

No-voltage input (with contacts, without contacts [count input, inhibit input, reset input])

Output

Control output

Maximum NPN open-collector output: 100 mA (40 V or less)

Control output

One-shot output time

0.01 s to 0.5 s (variable)

Relay

15 ms or less (when set to 30 Hz), 3 ms or less (when set to 5 kHz)

DC output

Rating

Power voltage

12 to 24 VDC ±10 %

Power consumption

Current consumption

150 mA or less

Environmental resistance

Insulation resistance

100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case

Noise resistance

Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Withstand voltage

1,000 VAC for 1 minute (between all the external terminals and the case)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 3 times in each of the X, Y, and Z directions

Weight

Approx. 120 g (main unit only)

*1 Display uses the zero suppression method.
*2 Option OP-91867 is required to perform surface or DIN rail mounting.

Keyence Stock Image
Keyence CA-LHR35 Keyence
Sale price €369,95
In stock, 11 units

Specifications

Model

CA-LHR35

Focal point

35 mm 1.38"

F-stop range (aperture)

F2.0 to F16

Minimum WD

0.1 m 0.3'

Mount

C-mount

Filter size

34.0 mm 1.34" P0.5

Compatible image sensor size

2/3"

TV distortion

0.05 % (-0.01 %)*1

Resolving power

200 cycles/mm at center, 140 cycles/mm on periphery

Ambient temperature/humidity range

0 to +50°C 32 to 122°F, 80% RH or less (No condensation)

Lens coating

WIDE, BAND MULTICOATING

Weight

Approx. 160 g

*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size.

keyence Stock Image
Keyence OP-33155 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-33155

Type

Screw Pipe Joint

Applicable product

AP-41, AP-43, AP-44

Cable end

M5 male threads (2) and M5 male thread (1).

keyence Stock Image
Keyence OP-88395 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88395*1

Material

Nylon Zinc nickel plating

Weight

Approx.12 g

*1 Use this when using a M12 connector type pressure sensor.

keyence Stock Image
Keyence OP-87627 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87627

Number included

1

Cable end

M8 straight - Loose wire

Length

2 m 6.56'

Material

Cable: PVCConnector: Zinc nickel plating

Weight

Approx. 60 g

keyence Stock Image
Keyence OP-51585 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CV-X202A Keyence
Sale price €3.028,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-SS2 Keyence
Sale price€0,00
Sold Out

Specifications

Model

GL-SS2

Type

Standard cable

Applicable product

GL-S Series main unit

Number included

1

Cable end

Main unit connection connector - Main unit connection connector

Length

2 m 6.56'

Note

Use this with one-line systems and series connections.

Weight

70 g

keyence Stock Image
Keyence OP-75722 Keyence
Sale price €680,95
Only 4 units left

Specifications

Model

OP-75722

Type

Connector Cable

Applicable product

M12 connector sensor

Cable end

Sensor side: M12 4-pin L-shape, Cable end: Loose wires

Length

2 m 6.56'

Material

PVC (Polyvinyl chloride)

Weight

Approx. 65 g

Keyence Stock Image
Keyence KV-7500L Keyence
Sale price €1.768,95
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence GL-R36H-R Keyence
Sale price €1.331,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-33156 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-33156

Applicable product

AP-40

Note

T-shaped One-touch Joint for f4

keyence Stock Image
Keyence FD-G200 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FD-G200

Pipe size

DN (Diameter Nominal)

150 A, 200 A

NPS (Nominal Pipe Size)

6", 8"

Outer diameter of pipe

ø163 to 171 mm 6.42" to 6.73", ø214 to 222 mm 8.43" to 8.74"

Pipe thickness

3.5 to 8.7 mm 0.14" to 0.34"

Supported pipe materials

Iron, steel, stainless steel

Supported fluids

Air, Nitrogen, other gases*1

Fluid temperature

0 to 60ºC 32 to 140 °F

Recommended pressure

0.4 MPa or greater (58 PSI or greater)

Rated velocity of flow range

Up to 15 m/s

Actual flow rate range (typical)

m3/h

Pipe size 150 A: 1000.0
Pipe size 200 A: 1800.0

L/min

Pipe size 150 A: 17000
Pipe size 200 A: 30000

CFM

Pipe size 150 A: 600.00
Pipe size 200 A: 1100.00

Standard flow rate range (typical) [CFM]

20°C 68°F 60 psi 0.41 MPa

Pipe size 150 A: 2842.15
Pipe size 200 A: 5210.62

20°C 68°F 80 psi 0.55 MPa

Pipe size 150 A: 3603.18
Pipe size 200 A: 6605.84

20°C 68°F 100 psi 0.69 MPa

Pipe size 150 A: 4364.21
Pipe size 200 A: 8001.06

20°C 68°F 120 psi 0.83 MPa

Pipe size 150 A: 5125.24
Pipe size 200 A: 9396.28

Display

QVGA 2.2" LCD color monitor

Display update cycle

Approx. 3 Hz

Display resolution

Instantaneous flow rate

0.1 m3/h, 1 L/min, 0.1 CFM

Consumption/leakage amount

0.1 m3, 1 L, 1 CF

Response time

1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

Measurement accuracy

Between 10 and 100% of F.S.

±2.0% of RD*2*3*4*5

Between 1 and 10% of F.S.

±1.0% of F.S.*2*3*4*5

Zero point error

±0.15% of F.S.*2*6

Static leakage repeatability

±1.0% of RD*4*7

Hysteresis

Variable

Flow units

CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

I/O wiring connection port

M12 4-pin connector (male)

Detection mode (switchable)

ch.1

Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8

ch.2

Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8

Standard I/O (switchable)

Control output (ch.1/ch.2)

NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

Analog output (ch.2)

4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

External input (ch.2)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

Analog input (for volume conversion)

M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

Power supplied to pressure sensor

Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

Communication interface

USB

USB 2.0

Ethernet

Standard

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps

Cable

Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable

Connector

M12 connector (female, D-code)

Network function

Modbus TCP, EtherNet/IP™, IO-Link*9

Recording capacity

Consumption amount/ leakage amount

Approx. 5 years

Events

100

Power supply

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2

Power consumption

350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),
550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*10

Ambient temperature

Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

Relative humidity

5 to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Display unit

Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

Detection head

Body: PPS/SUS304, rear surface: rubber

Mounting/damping bracket

SUS304

Weight

Approx. 2.8 kg

*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.
*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.
*5 The linearity error characteristic due to the pipe is not included in this value.
*6 It is possible to reduce zero point errors by performing an origin adjustment.
*7 This is the value within the range where measurement accuracy is guaranteed.
*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.
• ch.1: Pulse(+) mode
• ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 The IP65/67 enclosure rating is lost when a USB connection is established.

keyence Stock Image
Keyence SV3-B020AK Keyence
Sale price€0,00
Sold Out

Specifications

Model

SV3-B020AK *1

General specifications

Applicable servo amplifier

SV3-020L2

Rated output

200 W

Rated torque

0.637 N·m *2

Instant maximum torque

2.23 N·m

Rated current

1.6 Arms

Instant maximum current

5.8 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.444 N·m/Arms

Rotor moment of inertia

0.327 ×10-4 kg·m2

Rated power rating

12.4 kW/s

Rated angle acceleration

19,400 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

15×*3

Approx. weight

1.4 kg 3.09 lb

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

0.637 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence MD-X1520 Keyence
Sale price€0,00
Sold Out

Specifications

Model

MD-X1520

Type

Marking unit (controller + head) 25 W Wide area

2D code reader add-in (sold separately)

MD-XAD1/MD-XAD1A

Console (sold separately)

MC-P1

Marking method

XYZ 3-Axis simultaneous scanning method

Marking laser

Type

YVO4 laser, Class 4 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1

Wavelength

1,064 nm

Output

25 W

Q-switch frequency

CW (continuous wave), 1 to 400 kHz

Guide laser/Working distance pointer

Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1

Marking area

330 x 330 x 42 mm
12.99" x 12.99" x 1.65"

Standard working distance (±variable width)

300 mm (±21 mm) 11.81" (±0.83")

Marking resolution

5 µm

Scan speed

Max. 8,000 mm/s 314.96"/s

Character type

Font

KEYENCE original font (numbers, letters, katakana, hiragana, kanji), user font, TrueType font, OpenType font*2

Barcode

CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E

2D code

QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix)

GS1 DataBar

GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, GS1 DataBar Limited,
GS1 DataBar Limited CC-A, GS1 DataBar Truncated, GS1 DataBar Truncated CC‐A

Logo image

Custom character font and logo (CAD) data, BMP/JPEG/PNG/TIFF

Marking conditions

Workpiece style

Stationary marking, Moving marking (constant, encoder)

Character size (marking height/width)

0.1 to 330 mm 0.004" to 12.99"

No. of registered programs

2,000 max.

No. of program blocks

256

I/O (Input/output)

Terminal block I/O, MIL connector I/O, contactor control I/O*3

Interface

RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*4

Head installation direction

All directions

Head cable length

4.3 ±0.1 m 0.17" ±0.01"

Cooling method

Forced air cooling

Rated voltage and power consumption

100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, 800 VA max.

Environmental resistance

Enclosure rating

IP64 (marking head)

Pollution degree

2

Overvoltage category

II

Ambient temperature for storage

-10 to +60 °C 14 to 140 °F (No freezing)

Ambient temperature

0 to +40 °C 32 to 104 °F

Ambient humidity for storage

30 to 85 % RH (No condensation)

Relative humidity

Weight

Controller: 23.0 kg
Head: 13.9 kg
Console: 2.0 kg

*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 The only TrueType and OpenType fonts supported are those fonts whose "Font embeddability" property is set to "Installable" or "Editable." This property can be viewed from the Properties dialog boxes of the fonts shown on the [Fonts] screen in [Control Panel].
*3 Supported models: MD-X1000C, MD-X1020C, MD-X1500C, MD-X1520C
*4 There are two USB ports: a Type A connector for connecting USB memory devices or a USB mouse and a Type B connector that is the dedicated port for Marking Builder 3 (ActiveX). The Ethernet port supports communication with Marking Builder 3 (ActiveX), TCP/IP communication, EtherNet/IP™, and PROFINET.

keyence Stock Image
Keyence SZ-VB03 Keyence
Sale price €3.346,95
Only 3 units left

Specifications

Model

SZ-VB03

Type

Mounting bracket

Applicable product

SZ-V Series

Number included

1

Material

SPHC

Note

Accessories: M5 screw x 4

Weight

Approx. 1,350 g

keyence Stock Image
Keyence OP-88521 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence GL-R71F Keyence
Sale price €1.450,95
Only 3 units left

Specifications

Model

GL-R71F

Detection capability

ø0.55" ø14 mm

Total length

28.35" 720mm

No. of beam

71

Detection height

27.56" 700mm

Protection height

28.50" 724mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

12.1

OFF→ON

56.9*2

All blocked→ON

85.2*3

Optical synchronization system
(Channel A or B)

ON→OFF

17.6

OFF→ON

65.3*2

All blocked→ON

107.4*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

66

Receiver

78

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1000 g

Receiver

1010 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Keyence New Stock Image
Keyence SZ-VU04 Keyence
Sale price €995,95
Only 9 units left

Specifications

Model

SZ-VU04

Type

Multi-function type

Weight

Approx. 420 g

Keyence New Stock Image
Keyence CV-X470F Keyence
Sale price €3.647,95
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence OP-88046 Keyence
Sale price €242,95
In stock, 11 units

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed