Data Acquisition
93 products
Showing 25 - 48 of 93 products

Specifications
Model |
NR-XH1W *1 |
|||
Applicable models |
NR-X100W/NR-500 |
|||
Supported languages |
English, Chinese (Simplified), Japanese |
|||
Packaged software |
WAVE LOGGER X, LAN TOOL X, File Viewer X |
|||
Programming interface |
Automation server (WAVE LOGGER X) |
|||
Communication interface |
USB |
Equipped with a USB 2.0 host (Type-A) interface*2 |
||
Ethernet |
Equipped with a 100 Base-TX interface *3 |
|||
Wireless LAN |
IEEE 802.11b/g/n (with NR-XW1) *3 |
|||
OS |
Windows 11 Home/Pro, Windows 10 Home/Pro/Enterprise or Windows 7 SP1 Home Premium/Professional/Ultimate (pre-installed)*4 |
|||
CPU |
Intel® CoreTM i3 processor (2.0 GHz) or equivalent |
|||
Memory capacity |
Windows 11: 4 GB or more, Windows 10, Windows 7: 2 GB or more |
|||
Required capacity for installation |
1 GB or more |
|||
Monitor |
Resolution: 1280 × 1024 pixels or higher, Display color: High Color (16 bit) or higher |
|||
When using the Excel transfer function |
Excel 2010 or later must be installed |
|||
*1 Windows and Excel are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. | ||||
Scroll



Specifications
Model |
NR-XJ1 |
|||
Applicable battery |
NR-XB1 Series |
|||
Charging part |
Charging method |
Constant current and constant voltage method |
||
Charging time |
1 battery: Approx. 3.0 hours, 2 batteries: Approx. 4.5 hours |
|||
Display |
Charging confirmation LED |
Green LED (Flashing: charging, Constant: charging complete) |
||
Power supply |
NR-XU1 AC adapter |
|||
Environmental resistance |
Ambient temperature |
5 to 40°C 41°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 410 g 14.47 oz |
|||
Scroll

Specifications
Model |
NR-XU15A |
|||
Battery |
Dedicated lithium-ion battery pack NR-XB1 Series × 2 |
|||
Display LED |
Status indicators |
Battery operation: Blue, With NR-X100W battery power: Green |
||
Battery level indicator |
30% or more remaining: Green, Less than 30% remaining: Red, No remaining battery: Off |
|||
Battery life (typical example) |
Using only the NR-X100W |
NR-TH08(P) |
Number of connected units / Power consumption: 1 |
|
NR-HA08(P)/NR-HV04/NR-ST04 |
Number of connected units / Power consumption: 1 |
|||
NR-CA04/NR-FV04 |
Number of connected units / Power consumption: 1 |
|||
NR-C512/NR-EN16 |
Number of connected units / Power consumption: 1 |
|||
Total power consumption of connected units |
Number of connected units / Power consumption: At 10 W |
|||
When using remote units and environment-resistant measurement units |
Total power consumption of units to be powered by the NR-X100W |
Number of connected units / Power consumption: At 10 W |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F*3 |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 370 g 13.06 oz (Not including NR-XB1A) |
|||
*1 The operating time is a typical example with a fully charged new battery. Contact KEYENCE for more information when combining measurement units. When using the NR-XCP30 (or the NR-XW1), the battery duration is found according to the following formula: length of time that the measurement unit is run × total power consumption/(total power consumption + 1.6 W (+1.2 W)). | ||||
Scroll

Specifications
Model |
NR-XTH08T |
|||
Input method |
Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system) |
|||
Number of input channels |
8*1 |
|||
Input connector type |
Miniature thermocouple connector (Universal type) |
|||
Measurement cycle |
Maximum sampling cycle: 10 ms (100 Hz) to 1 h |
|||
A/D converting system |
Delta-sigma method |
|||
A/D resolution |
24 bits |
|||
A/D integration time (noise filter) |
AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz) |
|||
Input type |
Thermocouple: K, J, E, T, R, S, B, N, C |
|||
Low pass filter |
PASS / 200 Hz / 20 Hz |
|||
Averaging |
Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average) |
|||
Reference contact compensation |
Switchable between internal and external |
|||
Reference contact compensation accuracy |
±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium) |
|||
Maximum input rating |
±30 V*2 |
|||
Maximum allowable input ground voltage |
Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDC |
|||
Withstand voltage |
Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute |
|||
Input impedance |
10 MΩ or more |
|||
Input signal source resistance |
2 kΩ or less |
|||
Thermocouple burnout detection |
Switchable between ON/OFF, When ON: Approx. 10 μA current detection*3 |
|||
Measurable range |
K: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°F |
|||
Measurement accuracy |
K: ±0.04% of rdg ±0.4°C ±0.7°F, ±0.43% of rdg ±0.1°C ±0.2°F |
|||
Display resolution |
K: 0.05°C 0.09°F |
|||
Buffer memory |
16M data*5 |
|||
Warm up time |
30 minutes or more |
|||
Common mode noise reduction ratio |
135 dB or more (up to 60 Hz DC) (typ.) *4 |
|||
Remote connection |
Dedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT) |
|||
Synchronization accuracy between remote connection units |
±1 μs*7 |
|||
Power supply |
Supplied from NR-X100W master unit |
|||
Power consumption |
5.0 W max. |
|||
Surrounding air temperature |
−40 to +85°C -40°F to +185°F*8 |
|||
Operating ambient humidity |
Max. 100% RH*9 |
|||
Vibration resistance |
100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*10 |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27) |
|||
Enclosure rating |
IP65/IP67 (IEC 60529) |
|||
Material |
Main unit case: Aluminum die-casting (coated) / PBT+PC / PC, Display: Reinforced glass, |
|||
Weight |
Approx. 660 g 23.30 oz |
|||
*1 Max. expansion: 64 ch (with 8 units connected, using NR-X100W) | ||||
Scroll

Specifications
Model |
NR-XR01 |
|||
Expansion remote connection |
Dedicated remote input port × 1 (Remote IN), Output port × 1 (Remote OUT) |
|||
Number of connectable measurement units |
Max. 8 units*2 |
|||
Continuous acquisition speed |
Max. 100 kHz for all acquisition channels*3 |
|||
Synchronization between measurement units |
±1 μs or less*4 |
|||
Power supply |
Supplied from NR-U5 AC adapter or NR-X100W master data collection unit (operation with no AC adapter) |
|||
Power supply |
Power consumption |
Approx. 2.9 W |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 210 g 7.41 oz |
|||
*1 Remote unit cables can be extended by connecting a remote extension cable. The total length of remote cables used in the system should be no more than 100 m 328.1'. The distance between the master data collection unit and remote units or between remote units should be no more than 60 m 196.9'. | ||||
Scroll

Specifications
Model |
NR-XHA08T |
|||
Input method |
Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system) |
|||
Number of input channels |
8*1 |
|||
Input connector type |
Dedicated 3-pin connector |
|||
Measurement cycle |
Maximum sampling cycle: 100 μs (10 kHz) to 60 s |
|||
A/D converting system |
Delta-sigma method |
|||
A/D resolution |
24 bits |
|||
A/D integration time (noise filter) |
AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz) |
|||
Input frequency band |
2 kHz (−3 dB or more) |
|||
Input type |
Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV |
|||
Averaging |
Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average) |
|||
Input impedance |
Voltage input ±2 V range or higher |
1 MΩ ±2% |
||
Voltage input ±1 V range or higher |
10 MΩ ±2% |
|||
Current input |
Approx. 100 Ω |
|||
Measurement range |
±60 V |
Measurable range: −60.000 to +60.000 V |
||
±20 V |
Measurable range: −22.000 to +22.000 V |
|||
±10 V |
Measurable range: −11.000 to +11.000 V |
|||
±5 V |
Measurable range: −5.5000 to +5.5000 V |
|||
±2 V |
Measurable range: −2.2000 to +2.2000 V |
|||
±1 V |
Measurable range: −1.1000 to +1.1000 V |
|||
±500 mV |
Measurable range: −550.00 to +550.00 mV |
|||
±200 mV |
Measurable range: −220.00 to +220.00 mV |
|||
±100 mV |
Measurable range: −110.000 to +110.000 mV |
|||
±20 mA |
Measurable range: −22.000 to +22.000 mA |
|||
Maximum input rating |
Voltage input: ±60 V, Current input: ±30 mA |
|||
Maximum allowable input ground voltage |
120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding) |
|||
Withstand voltage |
Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minute |
|||
Buffer memory |
16M data*3 |
|||
Warm up time |
30 minutes or more |
|||
Residual noise level |
0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz) |
|||
Common mode noise reduction ratio |
105 dB or more (up to 60 Hz DC) (typ.)*2 |
|||
Remote connection |
Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT) |
|||
Synchronization accuracy between remote connection units |
±1 μs*5 |
|||
Power supply |
Supplied from NR-X100W master unit |
|||
Power consumption |
5.8 W or less |
|||
Surrounding air temperature |
−40 to +85°C -40°F to +185°F*6 |
|||
Operating ambient humidity |
Max. 100% RH*7 |
|||
Vibration resistance |
100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*8 |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27) |
|||
Enclosure rating |
IP65/IP67 (IEC 60529) |
|||
Material |
Main unit case: Aluminum die-casting (coated), Display: Reinforced glass, Connectors: Brass (chromate processing), Connector protection cap: PBT+PC |
|||
Weight |
Approx. 690 g 24.36 oz |
|||
*1 Max. expansion: 64 ch (with 8 units connected, using NR-X100W) | ||||
Scroll

Specifications
Model |
NR-XCP30 |
|||
Display |
3.5" TFT color LCD, 240 × 320 dot |
|||
Applicable models |
NR-X100W*1 |
|||
Supported languages |
Japanese, English, Chinese (Simplified) |
|||
Power supply |
Power consumption |
1.6 W or less |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 290 g 10.24 oz |
|||
*1 Cannot be connected to the NR-XR01 remote unit. | ||||
Scroll

Specifications
Model |
NR-X100W |
|||
Main unit buffer memory capacity |
50M data*1 |
|||
Expansion memory |
SD card (SD/SDHC)*2 |
|||
PC interface |
USB |
USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) |
||
Ethernet |
RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3 |
|||
Wireless LAN |
Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3 |
|||
Network function |
FTP client function, FTP server function, SNTP client function |
|||
Display/operation |
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection |
|||
Expansion remote unit connection |
Dedicated remote connection connector × 2 (Remote OUT A port, B port) |
|||
Number of connectable measurement units |
Master data collection unit group |
Max. 8 units*4 |
||
Total with remote units connected |
Max. 72 units*5 |
|||
Continuous acquisition speed |
Master data collection unit group |
Max. 100 kHz for all acquisition channels *6 |
||
Total with remote units connected |
Max. 500 kHz for all acquisition channels *6*7 |
|||
Inter-unit synchronization |
Between measurement units in the master data collection unit group |
±1 μs or less *8 |
||
Between the master data collection unit and each remote unit / environment-resistant measurement unit | ||||
Time axis accuracy |
±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible |
|||
Synchronous trigger input (SYNC input) |
Performance specifications |
• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) |
||
Input specifications |
• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower |
|||
Control input |
Common specifications |
• Input type: Bidirectional voltage input |
||
Individual specifications |
• External trigger input (TRG IN): Edge input |
|||
Control output |
Common specifications |
• Output format: Photo MOS relay output |
||
Individual specifications |
• Trigger output (TRG OUT): N.O. output, one-shot output |
|||
Power supply |
• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less) |
|||
Power supply |
Power consumption |
8.4 W or less (excluding connected units) |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) |
|||
*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M. | ||||
Scroll







Specifications
Model |
OP-66853 |
|||
Type |
BNC terminal block*1 |
|||
*1 Cannot be used in the ±20 mA range. | ||||
Scroll




Specifications
Model |
OP-35413 |
|||
Type |
26-pin connector*1 |
|||
*1 NR-HA08 included items come pre-wired. | ||||
Scroll



