Controls
435 products
Showing 1 - 24 of 435 products

Specifications
Model |
CU-21TA |
|||
Type |
Multi-functional |
|||
External calibration input signal |
Connection sensor |
NPN open-collector output type or type with output with contacts (signal input and synchronization input) |
||
Input |
No. of inputs |
2 |
||
Minimum input time |
0.5 ms *1 |
|||
Input system |
Transistor (via NPN output device), contact (via limit switch/microswitch, etc.) |
|||
Control output |
Relay output: 1c, 250 VAC, 2 A (resistive load) |
|||
Timer |
ON-delay, OFF-delay, One-shot, timer OFF (selectable), 0 .05 to 1 s/0.5 to 10 s (selectable) |
|||
Functions |
Input signal inversion, edge sync. / level sync. selectable, AND logic |
|||
Operation mode |
Timer, standard, synchronous |
|||
Control output |
Relay contact |
250 VAC 2A SPDT (1c) (resistive load) |
||
Transistor |
NPN: 100 mA (40 VDC) max. *2*3 |
|||
DC output |
12 VDC ±10%, 200 mA max. |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
7 VA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Accessories |
Plastic screwdriver |
|||
Weight |
Approx. 120 g |
|||
*1 Required off time: 1.5 ms minimum. | ||||
Scroll

Specifications
Model |
CU-21A |
|||
Type |
Standard |
|||
External calibration input signal |
Connection sensor |
NPN open-collector output type or type with output with contacts (signal input and synchronization input) |
||
Input |
No. of inputs |
2 |
||
Minimum input time |
5 ms *1 |
|||
Input system |
Transistor (via NPN output device), contact (via limit switch/microswitch, etc.) |
|||
Control output |
Relay output: 1c, 250 VAC, 2 A (resistive load) |
|||
Timer |
― |
|||
Functions |
AND logic |
|||
Operation mode |
Standard, synchronous |
|||
Control output |
Relay contact |
250 VAC 2A SPDT (1c) (resistive load) |
||
Transistor |
―*2 |
|||
DC output |
12 VDC ±10%, 200 mA max. |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
7 VA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 105 g |
|||
*1 Required off time: 15 ms minimum. | ||||
Scroll

Specifications
Model |
OP-91867 |
|||
Type |
DIN-rail mounting attachment |
|||
Applicable product |
RC-13, 14, 18, 19 RT AP-80A |
|||
Note |
48 mm |
|||
Scroll

Specifications
Model |
RC2-23 |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 15 mm) |
|||
Number of digits |
6-digit display, -99,999 to 999,999*1 |
|||
Prescale function |
A |
― |
||
B | ||||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
― |
||
Mounting method |
Panel mount (embedding), stand mount (optional) |
|||
External calibration input signal |
Signal |
― |
||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 3 A or less (360 VA or less, resistive load) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
Relay output: 24 ms or less (when set to 30 Hz), 12 ms or less (when set to 5 kHz) |
|||
DC output |
12 VDC ± 10%, 50 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
11VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 240 g |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC2-22K |
|||
Operation method |
Addition, subtraction, addition and subtraction |
|||
Operation mode |
Overcount, auto reset, rotary, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 14 mm) |
|||
Number of digits |
5-digit display (zero suppression method), -9,999 to 99,999*1 |
|||
Prescale function |
A |
1 to 99 is counted per pulse input |
||
B |
1 is counted per 1 to 99,999 pulse inputs |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
Separate, instruction, phase difference |
||
Mounting method |
Panel mount (embedding) |
|||
External calibration input signal |
Signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
||
Highest counting speed |
With contacts: 50 Hz, without contacts: 500 Hz, 5 kHz, 50 kHz (switchable; 1:1 ON:OFF ratio) |
|||
Control output |
One-shot output time |
0.01 s to 9.99 s (variable) |
||
Relay |
Open-collector output: 10 ms (when set to 50 Hz), 1 ms (when set to 500 Hz), 100 µs (when set to 5 kHz), 15 µs (when set to 50 kHz) |
|||
DC output |
12 VDC ± 10%, 100 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
12VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the AC external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
500 VAC for 1 minute (between all the external terminals and the case) |
|||
Weight |
Approx. 320 g |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC2-22 |
|||
Type |
Two-stage preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction, addition and subtraction |
|||
Operation mode |
Overcount, auto reset, rotary, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset |
|||
Display power |
7-segment LED (character height: 14 mm) |
|||
Number of digits |
5-digit display (zero suppression method), -9,999 to 99,999*1 |
|||
Prescale function |
A |
1 to 99 is counted per pulse input |
||
B |
1 is counted per 1 to 99,999 pulse inputs |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
Separate, instruction, phase difference |
||
Mounting method |
Panel mount (embedding) |
|||
External calibration input signal |
Signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
||
Highest counting speed |
With contacts: 50 Hz, without contacts: 500 Hz, 5 kHz, 50 kHz (switchable; 1:1 ON:OFF ratio) |
|||
Input signal |
― |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 2 A × 2 (125 VA or less); maximum NPN open-collector output: 100 mA (40 V or less); residual voltage: 1 V or less; hold/one-shot (switchable) |
||
Control output |
One-shot output time |
Can be set to an arbitrary value between 0.01 and 9.99 seconds (in units of 0.01 seconds) |
||
Relay |
Open-collector output: 10 ms (when set to 50 Hz), 1 ms (when set to 500 Hz), 100 µs (when set to 5 kHz), 15 µs (when set to 50 kHz) |
|||
DC output |
12 VDC ± 10%, 100 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
12VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the AC external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
500 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.75 mm 0.03", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 320 g |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC2-21K |
|||
Operation method |
Addition, subtraction, addition and subtraction |
|||
Operation mode |
Overcount, auto reset, rotary, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 14 mm) |
|||
Number of digits |
5-digit display (zero suppression method), -9,999 to 99,999*1 |
|||
Prescale function |
A |
1 to 99 is counted per pulse input |
||
B |
1 is counted per 1 to 99,999 pulse inputs |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
Separate, instruction, phase difference |
||
Mounting method |
Panel mount (embedding) |
|||
External calibration input signal |
Signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
||
Highest counting speed |
With contacts: 50 Hz, without contacts: 500 Hz, 5 kHz, 50 kHz (switchable; 1:1 ON:OFF ratio) |
|||
Control output |
One-shot output time |
0.01 s to 9.99 s (variable) |
||
Relay |
Relay output: 13 ms (when set to 50 Hz), 4 ms (when set to 500 Hz), 4 ms (when set to 5 kHz), 4 ms (when set to 50 kHz) |
|||
DC output |
12 VDC ± 10%, 100 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
12VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the AC external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
500 VAC for 1 minute (between all the external terminals and the case) |
|||
Weight |
Approx. 320 g |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC2-21 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction, addition and subtraction |
|||
Operation mode |
Overcount, auto reset, rotary, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset |
|||
Display power |
7-segment LED (character height: 14 mm) |
|||
Number of digits |
5-digit display (zero suppression method), -9,999 to 99,999*1 |
|||
Prescale function |
A |
1 to 99 is counted per pulse input |
||
B |
1 is counted per 1 to 99,999 pulse inputs |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Input |
System |
Separate, instruction, phase difference |
||
Mounting method |
Panel mount (embedding) |
|||
External calibration input signal |
Signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
||
Highest counting speed |
With contacts: 50 Hz, without contacts: 500 Hz, 5 kHz, 50 kHz (switchable; 1:1 ON:OFF ratio) |
|||
Input signal |
― |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 2 A (125 VA or less); maximum NPN open-collector output: 100 mA (40 V or less); residual voltage: 1 V or less; hold/one-shot (switchable) |
||
Control output |
One-shot output time |
Can be set to an arbitrary value between 0.01 and 9.99 seconds (in units of 0.01 seconds) |
||
Relay |
Relay output: 13 ms (when set to 50 Hz), 4 ms (when set to 500 Hz), 4 ms (when set to 5 kHz), 4 ms (when set to 50 kHz) |
|||
DC output |
12 VDC ± 10%, 100 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
12VA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the AC external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
500 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.75 mm 0.03", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 320 g |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC-19 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 12 mm) |
|||
Number of digits |
4-digit display, -999 to 9,999*1 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount*2 |
|||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
15 ms or less (when set to 30 Hz), 3 ms or less (when set to 5 kHz) |
|||
DC output |
― |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
― |
|||
Current consumption |
150 mA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 120 g (main unit only) |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC-18 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 12 mm) |
|||
Number of digits |
4-digit display, -999 to 9,999*1 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount*2 |
|||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 3 A or less (resistive load) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
24 ms or less (when set to 30 Hz), 12 ms or less (when set to 5 kHz) |
|||
DC output |
12 VDC ± 10%, 50 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
9VA or less |
|||
Current consumption |
- |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 170 g (main unit only) |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC-16 |
|||
Type |
1-level preset counter, DC type |
|||
Function selection |
- |
|||
Operation method |
Addition, subtraction, addition and subtraction (phase difference) |
|||
Operation mode |
Overcount, auto reset, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LCD (character height: 8.5 mm 0.33") |
|||
Number of digits |
6-digit display (zero suppression method), -99,999 to 999,999 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Timer accuracy |
- |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount |
|||
Highest counting speed |
With contacts: 30 c/s, without contacts: 1 kc/s (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less*1 |
||
Control output |
Relay |
Relay output: 20 ms or less (when set to 30 c/s), 5 ms or less (when set to 1 kc/s); |
||
DC output |
- |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
- |
|||
Current consumption |
45 mA or less |
|||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1.2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 75 g |
|||
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. | ||||
Scroll

Specifications
Model |
RC-15 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Function selection |
Counter, timer (switchable by way of a switch) |
|||
Operation method |
Addition, subtraction, addition and subtraction (phase difference) |
|||
Operation mode |
Counter: over count, auto reset, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (counter: in auto reset mode, timer: in flicker mode) |
|||
Display power |
7-segment LCD (character height: 8.5 mm) |
|||
Number of digits |
6-digit display (zero suppression method) |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Timer accuracy |
100 hours: ±0.01% ± 1 s (percentage of the time-up value), 1,000 seconds: ±0.01% ± 1 ms (percentage of the time-up value) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount |
|||
Highest counting speed |
With contacts: 30 c/s, without contacts: 1 kc/s (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less*1 |
||
Control output |
Relay |
Open-collector output: 15 ms or less (when set to 30 c/s), 2 ms or less (when set to 1 kc/s) |
||
DC output |
- |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
- |
|||
Current consumption |
45 mA or less |
|||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1.2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 75 g |
|||
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. | ||||
Scroll

Specifications
Model |
RC-14 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 10 mm) |
|||
Number of digits |
6-digit display, -99,999 to 999,999*1 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount*2 |
|||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
15 ms or less (when set to 30 Hz), 3 ms or less (when set to 5 kHz) |
|||
DC output |
― |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
― |
|||
Current consumption |
150 mA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 120 g (main unit only) |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC-13 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 10 mm) |
|||
Number of digits |
6-digit display, -99,999 to 999,999*1 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount*2 |
|||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 3 A or less (resistive load) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
24 ms or less (when set to 30 Hz), 12 ms or less (when set to 5 kHz) |
|||
DC output |
12 VDC ± 10%, 50 mA maximum |
|||
Rating |
Power voltage |
100 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
9.5VA or less |
|||
Current consumption |
- |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 170 g (main unit only) |
|||
*1 Display uses the zero suppression method. | ||||
Scroll

Specifications
Model |
RC-12 |
|||
Type |
1-level preset counter, AC type*1 |
|||
Function selection |
- |
|||
Operation method |
Addition, subtraction, addition and subtraction (phase difference) |
|||
Operation mode |
Overcount, auto reset, range distinction |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LCD (character height: 8.5 mm 0.33") |
|||
Number of digits |
6-digit display (zero suppression method), -99,999 to 999,999 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Timer accuracy |
- |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount |
|||
Highest counting speed |
With contacts: 30 c/s, without contacts: 1 kc/s (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Relay output: 1c, 250 VAC, 2 A (resistive load); maximum NPN open-collector output: 100 mA (40 V or less); residual voltage: 1 V or less*2 |
||
Control output |
Relay |
Relay output: 20 ms or less (when set to 30 c/s), 5 ms or less (when set to 1 kc/s); |
||
DC output |
12 VDC ± 10%, 50 mA maximum |
|||
Rating |
Power voltage |
100 to 120/200 to 240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
6VA or less |
|||
Current consumption |
- |
|||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 1.2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 230 g |
|||
*1 This product does not comply with EMC directive. | ||||
Scroll

Specifications
Model |
OP-51629 |
|||
Overview |
Side-mounting bracket MS2-H75/H100. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H75/H100 |
|||
Weight |
Approx. 88 g |
|||
Scroll

Specifications
Model |
OP-51628 |
|||
Overview |
Bottom-mounting bracket MS2-H75/H100. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H75/H100 |
|||
Weight |
Approx. 100 g |
|||
Scroll

Specifications
Model |
OP-51627 |
|||
Overview |
Front-mounting bracket MS2-H75/H100. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H75/H100 |
|||
Weight |
Approx. 106 g |
|||
Scroll

Specifications
Model |
OP-51626 |
|||
Overview |
Side-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 51 g |
|||
Scroll

Specifications
Model |
OP-51625 |
|||
Overview |
Bottom-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 79 g |
|||
Scroll

Specifications
Model |
OP-51624 |
|||
Overview |
Front-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 67 g |
|||
Scroll

Specifications
Model |
OP-42207 |
|||
Type |
Parallel operation unit |
|||
Applicable product |
MS Series |
|||
Note |
Used when performing parallel operation with the MS2-H Series |
|||
Weight |
Approx. 157 g |
|||
Scroll

Specifications
Model |
OP-42176 |
|||
Type |
Side-mounting bracket |
|||
Overview |
Side mounting bracket for the MS-H150. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H150 |
|||
Note |
Includes 4 screws (M3) for mounting the main unit |
|||
Weight |
Approx. 103 g |
|||
Scroll

Specifications
Model |
OP-42175 |
|||
Type |
Bottom-mounting bracket |
|||
Overview |
Front-mounting bracket for the MS2-H150 (Also compatible with the CA-U3). This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS-H150, MS2-H150, CA-U3 |
|||
Note |
Includes 4 screws (M3) for mounting the main unit |
|||
Weight |
Approx. 82 g |
|||
Scroll