Siemens All

25001 products

Showing 985 - 1008 of 25001 products

Showing 985 - 1008 of 25001 products
View
LXM62DD27C21000 Schneider Electric
Schneider LXM62DD27C21000 Schneider Electric
Sale price €1.255,95
Only 4 units left

Lexium 62 Single Drive 27 A - accessory kit included

GV3P32 Schneider Electric
Schneider GV3P32 Schneider Electric
Sale price €147,95
Only 6 units left

Motor circuit breaker, TeSys GV3, 3P, 23-32 A, thermal magnetic, EverLink terminals

GV2P10 Schneider Electric
Schneider GV2P10 Schneider Electric
Sale price €112,95
Only 5 units left

Motor circuit breaker, TeSys GV2, 3P, 4-6.3 A, thermal magnetic, screw clamp terminals

GV2P07 Schneider Electric
Schneider GV2P07 Schneider Electric
Sale price €108,95
Only 7 units left

Motor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, thermal magnetic, screw clamp terminals

BMXXBE1000 Schneider Electric
Schneider BMXXBE1000 Schneider Electric
Sale price €187,95
In stock, 16 units

backplane expander M340 - for multiracks configuration

BMXEHC0200 Schneider Electric
Schneider BMXEHC0200 Schneider Electric
Sale price €306,95
In stock, 33 units

high speed counter module M340 - 2 channels

BMXDDO3202K Schneider Electric
Schneider BMXDDO3202K Schneider Electric
Sale price €236,95
Only 1 unit left

This product is part of the Modicon X80 range, a common platform of modules for Modicon M580 and M340 Programmable Automation Controllers (PAC). This discrete output module has 32 outputs with sink (positive) logic. It is a discrete output module with an output voltage of 24V, 19V DC to 30V DC, a maximum power dissipation of 3.6W, a typical current consumption 125mA at 3.3V DC and 0.1A current per channel. This product is robust, high quality and based on the latest innovative technology. Protection types are reverse polarity protection, external short-circuit protection, overload protection and overvoltage protection. It offers 312254 hours of MTBF. It is an IP20 rated product. It weighs 0.11kg. It is suitable for medium to large process applications. This product is certified by EAC, Merchant Navy, CSA, RCM, CE and UL. It meets EN 61131-2, EN 61000-6-4, EN 61000-6-2 and EN 61010-2-201 standards. Modicon X80 consists in a compatible modules common platform that reduce maintenance and training costs with same spare parts in stock, and unique training for different Programmable Automation Controllers (PAC).

Main

Characteristic Value(s)
Range of Product Modicon X80
Product or Component Type Discrete output module
Discrete output number 32 EN/IEC 61131-2
Discrete output type Solid state
Discrete output logic Positive
Discrete output voltage 24 V 19...30 V DC
Discrete output current 0.1 A

Complementary

Characteristic Value(s)
Current per channel 0.125 A
Maximum current per module 3.2 A
Maximum leakage current 0.1 mA at state 0
Maximum voltage drop <1.5 V at state 1
Insulation resistance > 10 MOhm 500 V DC
Power dissipation in W 3.6 W
Response time on output 1.2 ms
Paralleling of outputs Yes : 3 maximum
Typical current consumption 125 mA 3.3 V DC
MTBF reliability 290000 H
Protection type External fuse reverse polarity protection
short-circuit protection
overload protection
overvoltage protection
Output overload protection With current limiter
With electronic circuit breaker 0.125 A < Id < 0.185 A
Output overvoltage protection With transil diode
Output short-circuit protection With 2 A external fuse
Reverse polarity protection Reverse mounted diode
Voltage detection threshold < 14 V DC preactuator fault
> 18 V DC preactuator at state 0
Maximum tungsten load 1.2 W
Switching frequency 0.5/LI² Hz
Maximum overload time 15 ms
Load impedance ohmic >= 220 Ohm
Status LED 1 LED (Green) module operating (RUN)
1 LED per channel (Green) channel diagnostic
1 LED (Red) module error (ERR)
1 LED (Red) module I/O
Product Weight 0.24 lb(US) (0.11 kg)
BMEXBP1002 Schneider Electric
Schneider BMEXBP1002 Schneider Electric
Sale price €559,95
In stock, 20 units

rack X80 - 10 slots - Redundant PS - Ethernet backplane

VW3A3203 Schneider Electric
Schneider VW3A3203 Schneider Electric
Sale price €270,95
Only 1 unit left

This I/O expansion module enables your drive to meet the needs of application that manage additional or specific sensors. It is simple to install and remove from Altivar drives thanks to its modular withdrawable design. It is compatible with Altivar Process ATV600, Altivar Process ATV900 and Altivar Machine ATV340. It is also compatible with Altivar Easy 610. It has one removable spring terminal block 1.5 mm² / AWG 16.

Main

Characteristic Value(s)
Product or Component Type Additional I/O module
Range Compatibility Altivar Process ATV600
Altivar Machine ATV340
Altivar Process ATV900
Easy Altivar 610
Input/Output Type 2 analog input configurable voltage, current or probe
6 discrete input
2 discrete output
Analogue input number 2
Analogue input type AI4, AI5 configurable current 0...20 mA/4...20 mA 0…1 ms 14 bits
AI4, AI5 configurable voltage - 10...10 V DC, 24 V max 20 kOhm 0…1 ms 14 bits
AI4, AI5 configurable PTC, Pt 100, Pt 1000 0…1 ms 14 bits
Discrete output number 2
Discrete output type DQ11, DQ12) assignable logic 1 ms
Discrete output logic DQ11, DQ12) negative
DQ11, DQ12) positive
Discrete input number 6
Discrete input type DI11...DI16) programmable 250 Ohm 1 ms
Discrete input logic Negative DI11...DI16)
Positive DI11...DI16)
Discrete input current 2.5 mA

Complementary

Characteristic Value(s)
Discrete output voltage 24 V DC <= 30 V) assignable logic
Maximum output current 100 mA, assignable logic
Discrete input voltage 24 V DC <= 30 V)programmable
Electrical connection Removable spring terminal block, 1.5 mm² / AWG 16
Protection type Reverse polarity protection digital input
Short-circuit protection output
Product Weight 1.1 lb(US) (0.5 kg)
VW3A31207 Schneider Electric
Schneider VW3A31207 Schneider Electric
Sale price €200,95
Only 6 units left

This PROFIBUS DP communication card is an option for variable speed drives of Altivar range. It is equipped with 3 connectors, 1 removable screw terminal block, 1 screw terminal block for connection to the PROFIBUS DP bus, 1 RJ45 connector for connection to the Modbus serial link. It is compatible with Altivar 312 drives. It enables integration of your variable speed drive in your process control network. It weighs 200g.

Main

Characteristic Value(s)
Product or Component Type Communication card
Range Compatibility Altivar 312 Solar
Altivar 312
Communication Port Protocol Profibus DP
Electrical connection 1 connector RJ45, Modbus
1 removable screw terminal block for inputs/outputs
Screw terminal block, Profibus DP
Transmission Rate 9600 bps, 19.2, 93.75, 187.5, 500 kbps, 1.5, 3, 6 or 12 Mbps
Number of addresses 1…127

Complementary

Characteristic Value(s)
Input/output number AI2 and AI3 2 analog input
LI1...LI3 3 logic input
R2 1 relay output
Communication Service Periodic variables output : 4 PKW and 2 PZD
CiA 402 profile
Messaging via PKW periodic variables
Periodic variables input : 4 PKW and 2 PZD
Display type 1 LED
1 LED ST (status)
Product Weight 0.4 lb(US) (0.2 kg)
TSXP573623AM Schneider Electric
Schneider TSXP573623AM Schneider Electric
Sale price €3.537,95
In stock, 15 units

Main

Characteristic Value(s)
Range of Product Modicon Premium Automation platform
Product or Component Type Double-format PL7 processor
Software Designation PL7 Junior/Pro

Complementary

Characteristic Value(s)
Concept Transparent Ready
Number of racks 16 4/6/8 slots
8 12 slots
Number of slots 96
128
64
Discrete I/O processor capacity 1024 I/O
Analogue I/O processor capacity 128 I/O
Number of application specific channel 32
Number of process control channel 15 up to 45 simple loops
Integrated connection type Ethernet TCP/IP RJ4510/100 Mbit/s)
Non isolated serial link 2 female mini DIN19.2/115 kbit/s)
Communication module processor capacity 1 fieldbus modules (1 if CANopen used)
8 AS-Interface bus modules
2 fieldbus
2 network module
Memory description Internal RAM (with PCMCIA card) 80 Kwords data
Internal RAM (without PCMCIA card) 64 Kwords program and data
PCMCIA card 2688 Kwords additional data storage
PCMCIA card 384 Kwords program
Maximum size of object areas 16384 %Mi located internal bits
30.5 %MWi internal words located internal data
32 %KWi constant words located internal data
Application structure 1 master task
1 fast task
64 event tasks
Execution time per instruction 2.6 µs floating points with PCMCIA card
0.12 µs Boolean without PCMCIA card
0.17 µs Boolean with PCMCIA card
0.17 µs word or fixed-point arithmetic without PCMCIA card
0.33 µs word or fixed-point arithmetic with PCMCIA card
2.5 µs floating points without PCMCIA card
Number of instructions per ms 3.08 Kinst/ms 65 % Boolean + 35 % fixed arithmetic with PCMCIA card
4.49 Kinst/ms 100 % Boolean with PCMCIA card
4.7 Kinst/ms 65 % Boolean + 35 % fixed arithmetic without PCMCIA card
6.57 Kinst/ms 100 % Boolean without PCMCIA card
System overhead 0.29 ms fast task
1.15 ms master task
Marking CE
Local signalling 1 LED (green) for Ethernet TCP/IP port ready (RUN)
1 LED (green) for processor running (RUN)
1 LED (red) for collision detection (COL)
1 LED (red) for Ethernet TCP/IP port fault (ERR)
1 LED (red) for I/O module or configuration fault (I/O)
1 LED (red) for processor or system fault (ERR)
1 LED (yellow) for activity on the terminal port (TER)
1 LED (yellow) for Ethernet link diagnostics (STS)
1 LED (yellow) for reception activity (RX)
1 LED (yellow) for transmission activity (TX)
Current consumption 1360 mA 5 V DC
Module format Double
Product Weight 1.68 lb(US) (0.76 kg)
TSXETG100 Schneider Electric
Schneider TSXETG100 Schneider Electric
Sale price €1.762,95
Only 7 units left

Main

Characteristic Value(s)
Range of Product ConneXium
Product or Component Type Ethernet Modbus gateway/router
Product destination All products compatible with Modbus standard
Concept Transparent Ready
Web server Class B10
[Us] rated supply voltage 24 V DC

Complementary

Characteristic Value(s)
Web services Via predefined web pages : diagnostic on Ethernet and Modbus links
Predefined web pages
Access to connected products list, reading of Modbus devices registers
Communication Service SNMP agent, device administration with a SNMP manager
Read/write Modbus registers of connected devices
Miniature firewall on-board (IP address filtering) and password protection
BOOTP protocol, FDR client
Supply Power supply device PoE IEEE 802.3af
Integrated connection type Ethernet TCP/IP RJ45 10/100 Mbps 1 twisted pair
Serial link 5-way removable terminal block Modbus RTU and ASCII RS485 57.6 kbps
Serial link micro switches Modbus RTU and ASCII RS485 57.6 kbps
Serial link RJ45 RS232 38.4 kbps
Maximum Number of Connected Devices Modbus serial link <32
Port Ethernet 10BASE-T/100BASE-TX
Mounting Support Symmetrical DIN rail
Marking CE
Local signalling for serial link communication (RS485, RX, TX) 3 LEDs
for Ethernet communication (LK, RX, TX, 100) 4 LEDs
Width 2.8 in (72 mm)
Height 3.2 in (81 mm)
Depth 3.0 in (76 mm)
TRV00917 Schneider Electric
Schneider TRV00917 Schneider Electric
Sale price €698,95
Only 4 units left

It is a spare part for the Micrologic cord for Compact NSX and PowerPact multistandard devices. This allows to connect the USB maintenance interface to the Micrologic trip unit.

Main

Characteristic Value(s)
Range of Product ComPact NSX100...250
ComPact NSX400...630
ComPact NSXm
Range ComPacT
Product or Component Type Testing cable
Accessory / separate part category Connection accessory
Device short name spare MicroLogic cord
Range compatibility ComPacT ComPacT NSX
PowerPact PowerPact Multistandard
TeSys TeSys GV4
Product Compatibility MicroLogic

Complementary

Characteristic Value(s)
Offer type Spare part
Compatibility code Spare MicroLogic cord
TM3AM6 Schneider Electric
Schneider TM3AM6 Schneider Electric
Sale price €182,95
In stock, 11 units

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue I/O module provides 4 inputs and 2 outputs with 11bit + sign and 12bit input resolution. It is an I/O module with a rated supply voltage of 24V DC, a current consumption of 45mA, 55mA at 5V DC via bus connector, 55mA, 100mA at 24V DC via external supply. This product is capable of controlling variable speed drives or any device equipped with a current or voltage input. There is an insulation between input and supply at 1500V AC, input and internal logic at 500V AC, output and supply at 1500V AC and output and internal logic at 500V AC. It is furnished with removable screw terminal for electrical connection with 3.18mm pitch adjustment for inputs and supply. It is an IP20 rated product. Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.11kg. This product is certified by CE. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller. It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

Main

Characteristic Value(s)
Range of Product Modicon TM3
Product or Component Type Input/output analog module
Range Compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 4
Analogue input type current 4...20 mA
current 0...20 mA
voltage 0...10 V
voltage - 10...10 V
Analogue output number 2
Analogue output type Current 4...20 mA
Current 0...20 mA
Voltage 0...10 V
Voltage - 10...10 V

Complementary

Characteristic Value(s)
Analogue input resolution 12 bits
11 bits + sign
Permissible continuous overload 13 V voltage
40 mA current
Input impedance <= 50 Ohm current
>= 1 MOhm voltage
Analogue output resolution 12 bits
11 bits + sign
LSB value 2.44 mV 0...10 V voltage
4.88 mV - 10...10 V voltage
4.88 µA 0...20 mA current
3.91 µA 4...20 mA current
Load type Resistive
Load impedance ohmic 1 kOhm voltage
300 Ohm current
Stabilisation time 1 ms
Conversion time 1 ms + 1 ms per channel + 1 controller cycle time
Sampling duration 1 ms
10 ms
Absolute accuracy error +/- 1 % of full scale
+/- 0.2 % of full scale at 77 °F (25 °C)
Temperature Drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS input
+/-0.5 %FS output
Non-linearity +/- 0.2 %FS
Output ripple 20 mV
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <98.4 ft (30 m) input/output
Current consumption 45 mA 5 V DC via bus connector no load
55 mA 5 V DC via bus connector full load
55 mA 24 V DC via external supply no load
100 mA 24 V DC via external supply full load
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs
10 x 1.5 mm² removable screw terminal block pitch 3.81 mm for inputs, outputs and supply
Insulation Between input and supply 1500 V AC
Between input and internal logic 500 V AC
Between output and supply 1500 V AC
Between output and internal logic 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode IEC 61000-4-5
0.5 kV power supply differential mode IEC 61000-4-5
1 kV I/O common mode IEC 61000-4-5
0.5 kV I/O differential mode IEC 61000-4-5
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 0.9 in (23.6 mm)
Product Weight 0.24 lb(US) (0.11 kg)
TM251MESE Schneider Electric
Schneider TM251MESE Schneider Electric
Sale price €631,95
Only 6 units left

Logic controller, Modicon M251, 2x Ethernet

TM241CE40R Schneider Electric
Schneider TM241CE40R Schneider Electric
Sale price €356,95
Only 8 units left

controller M241 40 IO relay Ethernet

TM221ME16R Schneider Electric
Schneider TM221ME16R Schneider Electric
Sale price €285,95
In stock, 15 units

This TM221 controller is part of the Modicon M221 Logic controller range. It has 16 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Main

Characteristic Value(s)
Range of Product Modicon M221
Product or Component Type Logic controller
[Us] rated supply voltage 24 V DC
Discrete input number 8, discrete input IEC 61131-2 Type 1
Analogue input number 2 0...10 V
Discrete output type Relay normally open
Discrete output number 8 relay
Discrete output voltage 5...125 V DC
5...250 V AC
Discrete output current 2 A

Complementary

Characteristic Value(s)
Discrete I/O number 16
Maximum number of I/O expansion module 7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits 20.4…28.8 V
Inrush current 35 A
Maximum power consumption in W 23.3 W 24 V with max number of I/O expansion module)
4.3 W 24 V without I/O expansion module)
Power supply output current 0.52 A 5 V expansion bus
0.46 A 24 V expansion bus
Discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time analog input
Permitted overload on inputs +/- 30 V DC 5 min maximum)analog input
+/- 13 V DC permanent)analog input
Voltage state 1 guaranteed >= 15 V input
Voltage state 0 guaranteed <= 5 V input
Discrete input current 7 mA discrete input
5 mA fast input
Input impedance 100 kOhm analog input
3.4 kOhm input
4.9 kOhm fast input
Response time 35 µs turn-off, I2...I5 input
5 µs turn-on, I0, I1, I6, I7 fast input
35 µs turn-on, other terminals input
5 µs turn-off, I0, I1, I6, I7 fast input
100 µs turn-off, other terminals input
5 µs turn-on, turn-off, Q0...Q1 output
50 µs turn-on, turn-off, Q2...Q3 output
300 µs turn-on, turn-off, other terminals output
Configurable filtering time 0 ms input
3 ms input
12 ms input
Output voltage limits 125 V DC
277 V AC
Maximum current per output common 7 A
Absolute accuracy error +/- 1 % of full scale analog input
Electrical durability 100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency 20 switching operations/minute with maximum load
Mechanical durability 20000000 cycles relay output
Minimum load 1 mA 5 V DC relay output
Protection type Without protection 5 A
Reset time 1 s
Memory capacity 256 kB user application and data RAM 10000 instructions
256 kB internal variables RAM
Data backed up 256 kB built-in flash memory backup of application and data
Data storage equipment 2 GB SD card optional)
Battery type BR2032 or CR2032X lithium non-rechargeable
Backup time 1 year 77 °F (25 °C) by interruption of power supply)
Execution time for 1 KInstruction 0.3 ms event and periodic task
0.7 ms other instruction
Execution time per instruction 0.2 µs Boolean
Exct time for event task 60 µs response time
Application structure 1 configurable freewheeling/cyclic master task
1 cyclic auxiliary task
8 interrupt tasks
Maximum size of object areas 512 %KW constant words
255 %C counters
8000 %MW memory words
255 %TM timers
512 %M memory bits
Realtime clock With
Clock drift <= 30 s/month 77 °F (25 °C)
Regulation loop Adjustable PID regulator up to 14 simultaneous loops
Function Available Frequency generator
PWM
PLS
Counting input number 4 fast input (HSC mode) 100 kHz 32 bits
counter function Single phase
A/B
Pulse/direction
Integrated connection type USB port mini B USB 2.0
Non isolated serial link serial 1 RJ45 RS232/RS485
Ethernet RJ45
Supply Serial 1)serial link supply 5 V, <200 mA
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232
480 Mbit/s USB
Communication port protocol USB port USB - SoMachine-Network
Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Ethernet
Port Ethernet 10BASE-T/100BASE-TX 1 328.08 ft (100 m) copper cable
Communication Service DHCP client
Modbus TCP slave device
Ethernet/IP adapter
Modbus TCP client
Modbus TCP server
Local signalling 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED per channel (green) for I/O state
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network link (yellow) for Link (Link Status)
Electrical connection terminal block, 3 for connecting the 24 V DC power supply
connector, 4 for analogue inputs
Mini B USB 2.0 connector for a programming terminal
removable screw terminal block, 10 for inputs
removable screw terminal block, 11 for outputs
Maximum cable distance between devices Shielded cable <32.8 ft (10 m) fast input
Unshielded cable <98.4 ft (30 m) output
Unshielded cable <98.4 ft (30 m) digital input
Unshielded cable <3.3 ft (1 m) analog input
Shielded cable <9.8 ft (3 m) fast output
Insulation Between input and internal logic 500 V AC
Between fast input and internal logic 500 V AC
Non-insulated between inputs
Between output and internal logic 500 V AC
Between output groups 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Marking CE
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 2.8 in (70 mm)
Product Weight 0.582 lb(US) (0.264 kg)
TM221M16T Schneider Electric
Schneider TM221M16T Schneider Electric
Sale price €203,95
In stock, 24 units

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 8 discrete, 4 fast inputs, 8 transistor, 2 fast outputs with PNP transistor output with 10bit resolution. It is a Modicon logic controller with a rated supply/output voltage of 24V DC, an output current of 0.5A with sink or source input logic and positive output logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS485 interface and non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface. It is a Modicon M221 controller with 256kB for user application and data RAM, internal variables RAM, 256kB built-in flash memory and a SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 70mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.264kg. This product is certified by CE, IACS E10, CSA, RCM, LR, ABS, DNV-GL, EAC and CULus. It meets EN/IEC 61010-2-201, EN/IEC 61131-2 and EN/IEC 60664-1 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks

Main

Characteristic Value(s)
Range of Product Modicon M221
Product or Component Type Logic controller
[Us] rated supply voltage 24 V DC
Discrete input number 8, discrete input 4 fast input IEC 61131-2 Type 1
Analogue input number 2 0...10 V
Discrete output type Transistor
Discrete output number 8 transistor 2 fast output
Discrete output voltage 24 V DC
Discrete output current 0.5 A

Complementary

Characteristic Value(s)
Discrete I/O number 16
Maximum number of I/O expansion module 7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits 20.4…28.8 V
Inrush current 35 A
Maximum power consumption in W 22 W 24 V with max number of I/O expansion module)
3.2 W 24 V without I/O expansion module)
Power supply output current 0.52 A 5 V expansion bus
0.49 A 24 V expansion bus
Discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time analog input
Permitted overload on inputs +/- 30 V DC 5 min maximum)analog input
+/- 13 V DC permanent)analog input
Voltage state 1 guaranteed >= 15 V input
Voltage state 0 guaranteed <= 5 V input
Discrete input current 7 mA discrete input
5 mA fast input
Input impedance 100 kOhm analog input
3.4 kOhm input
4.9 kOhm fast input
Response time 35 µs turn-off, I2...I5 input
5 µs turn-on, I0, I1, I6, I7 fast input
35 µs turn-on, other terminals input
5 µs turn-off, I0, I1, I6, I7 fast input
100 µs turn-off, other terminals input
5 µs turn-on, turn-off, Q0...Q1 output
50 µs turn-on, turn-off, Q2...Q3 output
300 µs turn-on, turn-off, other terminals output
Configurable filtering time 0 ms input
3 ms input
12 ms input
Discrete output logic Positive logic (source)
Maximum current per output common 4 A
Output frequency 100 kHz fast output (PWM/PLS mode) Q0...Q1
5 kHz output Q2...Q3
0.1 kHz output Q4...Q6
Absolute accuracy error +/- 1 % of full scale analog input
Maximum leakage current 0.1 mA transistor output
Maximum voltage drop <1 V
Mechanical durability 20000000 cycles transistor output
Maximum tungsten load <12 W output and fast output
Protection type Short-circuit and overload protection with automatic reset
Short-circuit protection on output
Overload and short-circuit protection 1 A
Reset time 1 s automatic reset
Memory capacity 256 kB user application and data RAM 10000 instructions
256 kB internal variables RAM
Data backed up 256 kB built-in flash memory backup of application and data
Data storage equipment 2 GB SD card optional)
Battery type BR2032 or CR2032X lithium non-rechargeable
Backup time 1 year 77 °F (25 °C) by interruption of power supply)
Execution time for 1 KInstruction 0.3 ms event and periodic task
0.7 ms other instruction
Execution time per instruction 0.2 µs Boolean
Exct time for event task 60 µs response time
Application structure 8 interrupt tasks
1 cyclic auxiliary task
1 configurable freewheeling/cyclic master task
Maximum size of object areas 8000 %MW memory words
255 %C counters
512 %KW constant words
255 %TM timers
512 %M memory bits
Realtime clock With
Clock drift <= 30 s/month 77 °F (25 °C)
Regulation loop Adjustable PID regulator up to 14 simultaneous loops
Positioning functions PTO 2 pulse/direction 100 kHz)
PTO 1 CW/CCW 100 kHz)
Function Available Frequency generator
PWM
PLS
Counting input number 4 fast input (HSC mode) 100 kHz 32 bits
counter function Single phase
Pulse/direction
A/B
Integrated connection type USB port mini B USB 2.0
Non isolated serial link serial 1 RJ45 RS485
Non isolated serial link serial 2 RJ45 RS232/RS485
Supply Serial 1)serial link supply 5 V, <200 mA
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232
480 Mbit/s USB
Communication port protocol USB port USB - SoMachine-Network
Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Communication Service Modbus master
Modbus slave
Local signalling 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
Electrical connection terminal block, 3 for connecting the 24 V DC power supply
connector, 4 for analogue inputs
Mini B USB 2.0 connector for a programming terminal
removable screw terminal block, 10 for inputs
removable screw terminal block, 11 for outputs
Maximum cable distance between devices Shielded cable <32.8 ft (10 m) fast input
Unshielded cable <98.4 ft (30 m) output
Unshielded cable <98.4 ft (30 m) digital input
Unshielded cable <3.3 ft (1 m) analog input
Shielded cable <9.8 ft (3 m) fast output
Insulation Between input and internal logic 500 V AC
Between fast input and internal logic 500 V AC
Non-insulated between inputs
Between output and internal logic 500 V AC
Between output groups 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between fast output and internal logic 500 V AC
Non-insulated between outputs
Marking CE
Mounting support Top hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height 3.5 in (90 mm)
Depth 2.8 in (70 mm)
Width 2.8 in (70 mm)
Product Weight 0.582 lb(US) (0.264 kg)
TM221CE16T Schneider Electric
Schneider TM221CE16T Schneider Electric
Sale price €248,95
In stock, 30 units

Logic controller, Modicon M221, 16 IO transistor PNP Ethernet

METSEPM8244 Schneider Electric
Schneider METSEPM8244 Schneider Electric
Sale price €3.439,95
Only 5 units left

The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. DIN rail mounting with remote display.

Main

Characteristic Value(s)
Range PowerLogic
product name PowerLogic PM8000
Product or Component Type Power meter
Device short name PM8244
Market segment Buildings large building cost management: billing: sub feeder
Buildings small building network management: main incomer
Buildings medium building network management: main incomer
Buildings large building network management: main incomer
Buildings large building network management: sub feeder
Buildings multi-site network management: main incomer
Buildings multi-site network management: sub feeder
Data center network management: main incomer
Data center network management: sub feeder
Healthcare network management: main incomer
Healthcare network management: sub feeder
Industry network management: main incomer
Industry network management: sub feeder
Utility: sub feeder
model type Standard

Complementary

Characteristic Value(s)
Power quality analysis EN 50160 2010 compliance report
IEEE 519 2014 compliance report
IEC 61000-4-30 class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
IEC 62586 power quality monitoring
disturbance direction detection
rapid voltage change
Device Application WAGES metering
Power monitoring
Type of measurement Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
supply voltage 90...415 V AC 45...65 Hz +/- 10 %
110...415 V DC +/- 10 %
Network Frequency 50 Hz
60 Hz
Line Rated Current 10 A
5 A
1 A
Poles description 3P
1P + N
3P + N
Power Consumption in VA 16 VA 230 V AC
Display Type Remote LCD display
Display Resolution 320 x 240 pixels QVGA
Sampling rate 256 samples/cycle
Measurement current 50…10000 mA
Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Frequency measurement range 42…69 Hz
Number of inputs 3 digital 30 V AC
3 digital 60 V DC
Measurement accuracy Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
Accuracy class Class 0.2S active energy IEC 62053-22
Class 0.2 active energy ANSI C12.20
Class 0.2 active power IEC 61557-12
Class 0.5S reactive energy IEC 62053-24
Class 0.5 power factor IEC 61557-12
Class 0.2 voltage IEC 61557-12
Class 0.2 current IEC 61557-12
Number of Outputs 1 pulse
Information displayed Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
Communication port protocol Modbus RTU 115 kbauds - 2-wire
ION 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
RSTP 801.1d 2004
Communication port support ETHERNET
Screw terminal block RS485
Communication Network Type IPv6 (internet protocol)
Data recording Sequence of event recording
Event logs
Min/max of instantaneous values
Harmonics logs
Alarm logs
GPS synchronisation
Waveform logs
Data logs
Time stamping
Trending/forecasting
Sag and swell logs
50 data recorders
Memory capacity 512 MB
Web services Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
Communication Service SMTP e-mail notification
RSTP support
NTP time synchronization
DHCP
PTP time synchronization
Cybersecurity Password protection
Syslog protocol support
Port hardening
Robust security logs
Enable/disable communication ports
Mounting Mode Flush-mounted
Clip-on
Mounting support DIN rail meter device
Framework remote display
Provided Equipment Remote display
Installation category III
Safety Construction III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Standards IEC 62053-22
IEC 62053-24
IEC 62052-11
IEC 61557-12
IEEE 1588
IEC 62586-2
IEC 61326-1
Product certifications CE
CULus
N998
Width 3.6 in (90.5 mm)
Depth 3.6 in (90.8 mm)
Height 3.6 in (90.5 mm)
Product Weight 18.6 oz (528 g)
LUCA32BL Schneider Electric
Schneider LUCA32BL Schneider Electric
Sale price €168,95
Only 6 units left

TeSys U standard control unit to be inserted in power bases LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. It provides full protection to motors with a rated current Ir 8-32A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys Ultra
product name TeSys Ultra
Device short name LUCA
Product or Component Type Standard control unit
Device Application Motor control
Motor protection
Product Specific Application Basic protection requirements for motor starters: overload and short-circuit
main function available Earth fault protection
Protection against overload and short-circuit
Manual reset
Protection against phase failure and phase imbalance
Product compatibility Power base LUB32
Power base LUB38
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B32BL
Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage 690 V AC
Network frequency 40...60 Hz
Load type 3-phase motor self-cooled
Utilisation category AC-43
AC-44
AC-41
Motor power kW 15 kW 400...440 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 690 V AC 50/60 Hz
rated motor current adjustment range 8…32 A
Thermal overload class Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2
Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
Tripping threshold 14.2 x Ir +/- 20 %
Phase failure sensitivity Yes
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Control circuit voltage limits 20...27 V DC 24 V in operation
14.5 V DC 24 V drop-out
Typical current consumption 220 mA 24 V DC I maximum while closing with LUB32
220 mA 24 V DC I maximum while closing with LUB38
80 mA 24 V DC I rms sealed with LUB32
80 mA 24 V DC I rms sealed with LUB38
Heat dissipation 3 W control circuit with LUB32
3 W control circuit with LUB38
Operating time 35 ms opening with LUB32 control circuit
35 ms opening with LUB38 control circuit
70 ms closing with LUB32 control circuit
70 ms closing with LUB38 control circuit
Standards EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
Product Certifications CE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage 690 V IEC 60947-6-2
600 V UL 60947-4-1
600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing mode Plug-in (front face)
Width 1.8 in (45 mm)
Height 2.6 in (66 mm)
Depth 2.4 in (60 mm)
Product Weight 0.298 lb(US) (0.135 kg)
Compatibility code LUCA
LUCA12FU Schneider Electric
Schneider LUCA12FU Schneider Electric
Sale price €131,95
In stock, 11 units

Standard control unit, TeSys U, 3-12A, 3P motors, thermal magnetic protection, class 10, coil 110-240V AC/DC

LC1F630 Schneider Electric
Schneider LC1F630 Schneider Electric
Sale price €2.799,95
Only 8 units left

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 481000V AC 40/400Hz, LX4 - 48...440V DC

LC1D38BD Schneider Electric
Schneider LC1D38BD Schneider Electric
Sale price €111,95
Only 7 units left

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 38A/690V AC-3/3e (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 25HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
38 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
38 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V DC

Complementary

Characteristic Value(s)
Motor power kW 18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
9 kW at 220...230 V AC 50/60 Hz (AC-3)
18.5 kW at 415...440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
9 kW at 220...230 V AC 50/60 Hz (AC-3e)
18.5 kW at 415...440 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors
10 hp at 200/208 V AC 50/60 Hz for 3 phase motors
5 hp at 240 V AC 50/60 Hz for 1 phase motors
20 hp at 480 V AC 50/60 Hz for 3 phase motors
25 hp at 600 V AC 50/60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
50 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 60 A 104 °F (40 °C) - 10 min for power circuit
430 A 104 °F (40 °C) - 1 s for power circuit
150 A 104 °F (40 °C) - 1 min for power circuit
310 A 104 °F (40 °C) - 10 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm - Ith 50 A 50 Hz for power circuit
Power dissipation per pole 5 W AC-1
3 W AC-3
3 W AC-3e
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 30 Mcycles
Electrical durability 1.4 Mcycles 50 A AC-1 <= 440 V
1.4 Mcycles 38 A AC-3 <= 440 V
1.4 Mcycles 38 A AC-3e <= 440 V
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W 5.4 W 68 °F (20 °C))
Hold-in power consumption in W 5.4 W 68 °F (20 °C)
Operating time 20 ±20 % ms opening
63 ±15 % ms closing
Time constant 28 ms
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.02 in² (1…10 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.009 in² (1.5…6 mm²) - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail