This Micrologic 6.2 A (Ammeter) is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an excellent choice for all standard and specific applications protection. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 A |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 100 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Ammeter |
| Communication of data | Maximeters/minimeters Instantaneous and demand values Power quality Demand current and power Protection and alarm settings Time-stamped histories and event tables Maintenance indicators Energy metering |
| Electrical data recording | Maintenance indicators |

This Micrologic 6.2 A (Ammeter) is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an excellent choice for all standard and specific applications protection. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 A |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 40 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 18...40 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Ammeter |
| Communication of data | Power quality Maximeters/minimeters Protection and alarm settings Time-stamped histories and event tables Demand current and power Energy metering Maintenance indicators Instantaneous and demand values |
| Electrical data recording | Maintenance indicators |

This Micrologic 6.2 E (Energy) is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 E indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 E is equipped with a display module that gives energy measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 E |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 100 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Energy meter |
| Communication of data | Time-stamped histories and event tables Power quality Demand current and power Protection and alarm settings Maximeters/minimeters Maintenance indicators Instantaneous and demand values Energy metering |
| Electrical data recording | Maintenance indicators |

This Micrologic 6.2 E (Energy) is a 3 poles 3d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 E indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 E is equipped with a display module that gives energy measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 E |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 40 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 18...40 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Energy meter |
| Communication of data | Energy metering Protection and alarm settings Time-stamped histories and event tables Maximeters/minimeters Power quality Instantaneous and demand values Demand current and power Maintenance indicators |
| Electrical data recording | Maintenance indicators |

This MA25 is a 3 poles 3d magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 25A rating magnetic trip unit is an optimum choice for motor protection applications. It embeds an adjustable instantaneous magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MA |
| Trip unit technology | Magnetic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 |
| Device Application | Motor |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | I |
| Protection type | I : for short-circuit protection (magnetic) |
| Trip unit rated current | 25 A 149 °F (65 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Instantaneous protection pick-up adjustment type Ii | Adjustable 9 settings |
| [Ii] instantaneous protection pick-up adjustment range | 6...14 x In |
| Earth-leakage protection | Without |

This MA2.5 is a 3 poles 3d magnetic trip unit used on Compact NSX 100 circuit breakers. This 2.5A rating magnetic trip unit is an optimum choice for motor protection applications. It embeds an adjustable instantaneous magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MA |
| Trip unit technology | Magnetic |
| Range Compatibility | ComPact NSX100 |
| Device Application | Motor |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | I |
| Protection type | I : for short-circuit protection (magnetic) |
| Trip unit rated current | 2.5 A 149 °F (65 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Instantaneous protection pick-up adjustment type Ii | Adjustable 9 settings |
| [Ii] instantaneous protection pick-up adjustment range | 6...14 x In |
| Earth-leakage protection | Without |

trip unit Micrologic 6.2 A for Compact NSX 100/160/250 circuit breakers, electronic, rating 100A, 4 poles 4d

This Micrologic 6.2 A (Ammeter) is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 40A rating electronic trip unit is an excellent choice for all standard and specific applications protection. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 A indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 A is equipped with a display module that gives current measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 A |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 4P |
| Protected poles description | 4t 3t + OSN 3t + N/2 3t |
| Neutral position | Left |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 40 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 18...40 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Neutral protection settings | 0.5 x Ir 3t + N/2) 1 x Ir 4t) 1.6 x Ir 3t + OSN) No protection 3t) |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Ammeter |
| Communication of data | Instantaneous and demand values Time-stamped histories and event tables Maximeters/minimeters Demand current and power Protection and alarm settings Power quality Energy metering Maintenance indicators |
| Electrical data recording | Maintenance indicators |

This Micrologic 6.2 E (Energy) is a 4 poles 4d electronic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating electronic trip unit is an optimum choice for all standard and specific applications. It embeds adjustable long time protection against overloads. It provides also adjustable short-time protection and instantaneous protection against short-circuits. It has an additional and adjustable ground fault protection. Micrologic 6.2 E indicates overloads with Alarm LEDs. The green Ready LED flashes if the circuit breaker is ready to trip. Micrologic 6.2 E is equipped with a display module that gives energy measurement and allows fine adjustment settings. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | MicroLogic 6.2 E |
| Trip unit technology | Electronic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX250 |
| Device Application | Distribution |
| Number of poles | 4P |
| Protected poles description | 3t + OSN 4t 3t + N/2 3t |
| Neutral position | Left |
| Trip unit protection functions | LSIG |
| Protection type | L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection |
| Trip unit rated current | 100 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15â¦400 s 1.5 x Ir 0.35â¦11 s 7.2 x Ir 0.5â¦16 s 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...12 x In Compact NSX250 1.5...15 x In Compact NSX100 1.5...15 x In Compact NSX160 |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In In = 40 A 0.2...1 x In In > 40 A Ig enable on/off |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0â¦0.4 s I²t=off 0.1â¦0.4 s I²t=on |
| Earth-leakage protection | Without |
| Neutral protection settings | 0.5 x Ir 3t + N/2) 1 x Ir 4t) 1.6 x Ir 3t + OSN) No protection 3t) |
| Zone selective interlocking ZSI | With |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type of Measurement | Energy meter |
| Communication of data | Power quality Demand current and power Instantaneous and demand values Maximeters/minimeters Protection and alarm settings Time-stamped histories and event tables Energy metering Maintenance indicators |
| Electrical data recording | Maintenance indicators |

trip unit Micrologic 6.2 E for Compact NSX 100/160/250 circuit breakers, electronic, rating 40A, 4 poles 4d

This TM63G is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 63A rating thermal-magnetic trip unit is an optimum choice for generator protection applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 ComPact NSX100...250 DC |
| Product or Component Type | Trip unit |
| Trip unit name | TM-G |
| Trip unit technology | Thermal-magnetic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Device Application | Generator |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 63 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network type | AC DC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120â¦400 s 1.5 x In |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 125 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |

This TM25G is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100 circuit breakers. This 25A rating thermal-magnetic trip unit is an optimum choice for generator protection applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 DC ComPact NSX100...250 |
| Product or Component Type | Trip unit |
| Trip unit name | TM-G |
| Trip unit technology | Thermal-magnetic |
| Range Compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Device Application | Generator |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 25 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network type | AC DC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120â¦400 s 1.5 x In |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 80 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |

This TM16G is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100 circuit breakers. This 16A rating thermal-magnetic trip unit is an optimum choice for generator protection applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of Product | ComPact NSX100...250 ComPact NSX100...250 DC |
| Product or Component Type | Trip unit |
| Trip unit name | TM-G |
| Trip unit technology | Thermal-magnetic |
| Range Compatibility | ComPact NSX100 ComPact NSX100 DC |
| Device Application | Generator |
| Number of poles | 3P |
| Protected poles description | 3t |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 16 A 104 °F (40 °C) |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network type | AC DC |
| Network Frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120â¦400 s 1.5 x In |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 63 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |

This TM63G is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 63A rating thermal-magnetic trip unit is an optimum choice for generator protection applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of product | ComPact NSX100...250 ComPact NSX100...250 DC |
| Product or component type | Trip unit |
| Trip unit name | TM-G |
| Trip unit technology | Thermal-magnetic |
| Range compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Device application | Generator |
| Number of poles | 4P |
| Protected poles description | 4t |
| Neutral position | Left |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network type | DC AC |
| Network frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120â¦400 s at 1.5 x In |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 125 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Neutral protection settings | 1 x Ir (4t) |

This TM40G is a 4 poles 4d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 40A rating thermal-magnetic trip unit is an optimum choice for generator protection applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and Compact NSX basic frame.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| Range of product | ComPact NSX100...250 DC ComPact NSX100...250 |
| Product or component type | Trip unit |
| Trip unit name | TM-G |
| Trip unit technology | Thermal-magnetic |
| Range compatibility | ComPact NSX100 ComPact NSX160 ComPact NSX100 DC |
| Device application | Generator |
| Number of poles | 4P |
| Protected poles description | 4t |
| Neutral position | Left |
| Trip unit protection functions | LI |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rated current | 40 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 750 V DC |
| Network type | DC AC |
| Network frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120â¦400 s at 1.5 x In |
| Short-time protection pick-up adjustment type Isd | Fixed |
| [Isd] Short-time protection pick-up adjustment range | 80 A |
| Short-time protection delay adjustment type tsd | Fixed |
| Earth-leakage protection | Without |
| Neutral protection settings | 1 x Ir (4t) |