Plug-in industrial relay with power contacts, 2 changeover contacts, test key, mechanical switch position indicator, polarity: bipolar, input voltage: 24 V DC
Uninterruptible power supply with integrated power supply unit. For lead AGM energy storage with 1.3 Ah to 12 Ah nominal capacity. Input: 1-phase, output: 24 V DC/5 A. Push-in connection technology
Plug-in octal relay with power contacts, 3 change-over contacts, test key, mechanical switch position display, coil voltage: 220VDC, response voltage at 23C without pre-excitation 60% ... 80% of the rated voltage (132VDC ... 176VDC)
Plug-in octal relay with power contacts, 2 change-over contacts, test key, mechanical switch position display, coil voltage: 220VDC, response voltage at 23C without pre-excitation 60% ... 80% of the rated voltage (132VDC ... 176VDC)
Analog output module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4...20mA, 0...20mA, 0...10V, 2...10V) can be configured via DIP switch, Push-in connection
Analog output module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4...20mA, 0...20mA, 0...10V, 2...10V) can be configured via DIP switch, screw connection
Pt 100/Pt1000 temperature transducer for PLC logic logic modules (Generation 2 only), single-channel, signal type (Pt 100, Pt 1000) can be configured via DIP switch, Push-in connection
Pt 100/Pt1000 temperature transducer for PLC logic logic modules (Generation 2 only), single-channel, signal type (Pt 100, Pt 1000) can be configured via DIP switch, screw connection
Analog input module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4...20mA, 0...20mA, 0...10V, 2...10V) can be configured via DIP switch, Push-in connection
Analog input module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4...20mA, 0...20mA, 0...10V, 2...10V) can be configured via DIP switch, screw connection
Two-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA 20 mA. Push-in connection technology.
Two-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA 20 mA. Screw connection technology.
Plug-in industrial relay with power contacts, 4 changeover contacts, test key, mechanical switch position indicator, polarity: bipolar, input voltage: 24 V DC
Single-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA 20 mA. Screw connection technology.
The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.
Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
FASTCON Pro plug set consisting of four plugs with screw connection, one for each position on the module. Suitable for all MINI Analog Pro modules.
Pre-assembled relay module with push-in connection, consisting of: relay base, power contact relay, plug-in display/suppressor module, and retaining bracket. Contact type: 1 PDT. Input voltage: 12 V DC
Assembled shielded round cable connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.) connection 2: D-SUB socket strip (1x 37-position) cable length: 10 m
Assembled shielded round cable connection 1: Single wires (25-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.) connection 2: D-SUB socket strip (1x 25-position) cable length: 10 m
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3�V, current limitation at 48�mA, line fault transparency, error message output, up to SIL�3 according to IEC�61508, Push-in connection.
Single-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA 20 mA. Push-in connection technology.
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3�V, current limitation at 48�mA, line fault transparency, error message output, up to SIL�3 according to IEC�61508 screw connection.