Digital I/O device for INTERBUS twisted pair with 500 kbaud, eight inputs (24 V DC), eight outputs (24 V DC, 0.5 A), sensor/actuator connection via 5-pos. M12 female connectors, rugged metal housing, IP67 protection
Digital input device for INTERBUS twisted pair with 500 kbaud, 16 inputs (24 V DC), sensor connection via 5-pos. M12 female connectors, rugged metal housing, IP67 protection
Inline digital output terminal block, without accessories, 1 relay changeover contact, gold contact, 5 - 253 V AC, 3A
Inline digital output terminal block, without accessories, 4 relay changeover contacts, gold contacts, 5 - 253 V AC, 3 A
Inline positioning terminal, without accessories, 1 absolute encoder input, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 500 mA, 3-conductor connection technology
Inline positioning terminal, without accessories, 1 incremental encoder input, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 500 mA, 3-conductor connection technology
Power bridge, for Inline power-level terminal blocks
Power plug, for Inline power-level terminals
Plug set, for Inline field multiplexers
Motor Protection Module
Separating plate, 2 mm thick, black, required at the start and end of a PI terminal strip where continuous bridges are used.
Base terminal block for non intrinsically safe signals with knife disconnection and test connections.
Ex-basic terminal block, with knife disconnection and integrated temperature measurement of the input terminal blocks for cold point compensation
2835862 ND 2835862 NON EX ISOLATING AMP 3 WAY.
Motherboard to accept 16 x PI-Nicht-Ex-i isolator modules (PI-N-...), three terminal points for the field side for every module, 37-pos. D-SUB pin strip for connection of the signals to the control system level, assembly on NS 32, or NS 35/7.5.
Non Ex Analog Output: output signal conditioner. Isolates and converts analog standard signals. With configurable input/output. 3-way isolated (input/output/supply).
Ex i output signal conditioner, HART-compatible. Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Galvanic 3-way isolation (input / output / supply). Line fault detection.
2835600 ND 2835600 EX I THERMOCOUPLE.
2835590 ND 2835590 EX I THERMOMETER TRANSDUCER.
Ex i motherboard to accept 16 x PI-Ex i isolator modules (PI-Ex-), three terminal points for the field side for every module, 37-pos. D-SUB pin strip for connection of the signals to the control system level, assembly on NS 32, or NS 35/7.5.
Ex universal module carrier (motherboard) to hold 3-conductor measuring transducers, intrinsically safe, for max. 8 PI- modules, for mounting on NS 35/7.5 or NS 32
Ex motherboard, intrinsically safe, for accommodating 16 PI/Ex- process interface modules, for assembly on NS 35/7.5 or NS 32
Ex i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted to a safe area. Relay output (N/C contact), line fault detection. Galvanic 3-way isolation.
2835312 ND 2835312 ADAPTER CABLES.