Three-phase solid-state contactor with 230 V AC input, 37 A output current, zero voltage switch, optionally with thermal fuse
Three-phase solid-state contactor with 230 V AC input, 2 A output current, zero voltage switch, optionally with thermal fuse
Three-phase power meter for active power measurement with direct measurement in networks of up to 500�V�/�80�A, with S0 output, with digital input and RS-485 interface, certified in accordance with the MID directive
Three-phase power meter for active power measurement with direct measurement in networks of up to 500�V�/�80�A, with S0 output, with digital input and MBUS interface, certified in accordance with the MID directive
Three-phase power meter for active power measurement with direct measurement in networks of up to 500�V�/�80�A, with S0 output, Ethernet interface, certified in accordance with the MID directive
Three-phase power meter for active power measurement with current transformer measurement 1�A�/�5�A in networks of up to 500�V, with S0 output, Ethernet interface, certified in accordance with the MID directive
Three-phase power meter for active power measurement with current transformer measurement 1�A�/�5�A in networks of up to 500�V, with S0 output, with digital input and RS-485 interface, certified in accordance with the MID directive
Three-phase power meter for active power measurement with current transformer measurement 1�A�/�5�A in networks of up to 500�V, with S0 output, with digital input and MBUS interface, certified in accordance with the MID directive.
Three-phase energy meter for real power measurement in networks up to 460�V�/�65�A, with 3 digital inputs and RS-485 interface, certified according to the MID directive
This is an individual product please order the complete set. The measuring transducer processes the mV signal of the upstream Rogowski coil. The measuring transducer has 8 current measuring ranges (100 A ... 4000 A AC) which can be set max. output current of 1 A AC.
The stand-alone device for PROFIBUS has 8 digital outputs each with a load capacity of 2 A. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for PROFIBUS has 8 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 600 mA.
The stand-alone device for PROFIBUS has 8 digital inputs and 8 digital outputs each with a load capacity of 500 mA. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for PROFIBUS has 4 digital inputs and 4 digital outputs each with a load capacity of 2 A. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for PROFIBUS has 16 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 1.2 A.
The stand-alone device for INTERBUS has 8 digital outputs each with a load capacity of 2 A. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for INTERBUS has 8 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 600 mA.
The stand-alone device for INTERBUS has 8 digital inputs and 8 digital outputs each with a load capacity of 500 mA. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for INTERBUS has 4 digital inputs and 4 digital outputs each with a load capacity of 2 A. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for INTERBUS has 16 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 1.2 A.
The stand-alone device for DeviceNet has 8 digital inputs and 8 digital outputs each with a load capacity of 500 mA. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload
The stand-alone device for DeviceNet� has 16 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 1.2 A.
The stand-alone device for CANopen� has 8 digital inputs and 8 digital outputs each with a load capacity of 500 mA. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload.
The stand-alone device for CANopen� has 16 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 1.2 A.