Digital output unit, 64 x transistor outputs, NPN, 0.5 A, 12 to 24 VDC, 2 x FCN40 connectors (not included)
Digital output module, 64-PNP (transistor sourcing) output, 24/DC 0.3A max switching capacity, 16 points/1 common, MIL connector, 4 word, 170 mA at 5DC max current consumption
Digital output module, 64-NPN (transistor sinking) output, 24/DC 0.3A max switching capacity, 16 points/1 common, MIL connector, 4 word, 170 mA at 5DC max current consumption
Controllers DC24V 64PT NPN MIL Output
Power supply unit, 100-240 VAC, output capacity: 25 W, with maintenance forecast monitor
Isolated analog input module, 10 ms/2 inputs, 1/64,000 resolution, removable terminal block, 180 mA max at 5/DC
Universal input-hi resolution analog module, 4 universal inputs, removable terminal block, 1 word allocation, screw terminals, 31 mm width, 0.3 A at 5/DC
Profibus-DP master module, 9.6 to 12Mbit/s, 7k words I/O and 25 words CIO, 9-pin female sub-D connector, rotary switch, 400 mA at 5/DC
ISOLATED THERMOCOUPLE INPUT UNIT, 2 X INPUTS (B, E, J, K, L, N, R, S, T, U, WRE-5-26, PL2; +/-100MV), 1:64,000 RESOLUTION, 10MS/2 INPUTS CONVERSION TIME
Input module, isolated-type thermocouple , 250 ms/4 inputs, removable terminal block, 250 mA max at 5/DC
Input module, isolated-type resistance thermometer, 250 ms/4 inputs, 3-wire method, removable terminal block,250 mA max at 5/DC
Serial communication unit, 2x RS-232C ports, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, Modbus-RTU, Modbus-ASCII, Host Link), Modbus RTU Slave
Serial high-speed communication unit, 2x RS-232C ports, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, MODBUS-RTU, MODBUS-ASCII, Host Link), MODBUS RTU Slave, up to 230 kbps
Serial communication unit, 2x RS422/485 ports, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, Modbus-RTU, Modbus-ASCII, Host Link), Modbus RTU Slave
Serial high-speed communication unit, 2x RS-422/485 ports, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, MODBUS-RTU, MODBUS-ASCII, Host Link), MODBUS RTU Slave, up to 230 kbps
Serial communication unit, 1x RS-232C port + 1x RS422/485 port, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, Modbus-RTU, Modbus-ASCII, Host Link), Modbus RTU Slave
Serial high-speed communication unit, 1x RS-232C port + 1x RS-422/485 port, Protocol Macro, Host Link, 1:N NT Link, No protocol, Serial Gateway (CompoWay/F, MODBUS-RTU, MODBUS-ASCII, Host Link), MODBUS RTU Slave, up to 230 kbps
CJ1 HIGH-SPEED DATA STORAGE AND PROCESSING UNIT, 1 X 10/100BASE-TX PORT, CF CARD SLOT