Filters
New products
25836 products
SIRIUS safety relay with relay enabling circuits (EC) 24 V DC, 45 mm overall width Screw terminal EC instantaneous: 3 NO EC delayed: 0 NO SC: 2 NC Autostart/monitored start Basic device Maximum achieved SIL: 3, PL: E
Contactor safety combination for safety circuits Enabling and signaling circuit 5 NO+1 NC DC operation 24 V DC
SIRIUS soft starter Values at 400 V, 40 °C Standard: 162 A, 90 kW Inside-delta: 281 A, 160 kW 200-460 V AC, 230 V AC Screw terminals
SIRIUS soft starter S12 356 A, 200 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals
SIRIUS soft starter S6 162 A, 90 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals
SIRIUS soft starter S6 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals
SIRIUS soft starter S3 106 A, 55 kW/400 V, 40 °C 200-480 V AC, 110-230 V AC/DC Screw terminals
SIRIUS soft starter S3 80 A, 45 kW/400 V, 40 °C 200-480 V AC, 110-230 V AC/DC Screw terminals
Circuit breaker size S0 for motor protection, CLASS 10 A-release 16...22 A N-release 286 A screw terminal Standard switching capacity
3RV2011-1JA10 SIEMENS Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.1...1.6 A N-release 21 A screw terminal Standard switching capacity
Circuit breaker size S3 for motor protection, CLASS 10 A-release 80...100 A N-release 1235 A Screw terminal Standard switching capacity
Circuit breaker size S3 for motor protection, CLASS 10 A-release 45...63 A N-release 819 A Screw terminal Standard switching capacity
Circuit breaker size S2 for motor protection, CLASS 10 A-release 36...45 A N-release 585 A Screw terminal Standard switching capacity
Circuit breaker size S0 for motor protection CLASS 10 A-release 2.8...4 A Short-circuit release 52 A Screw terminal Standard switching capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2011-1EA10<< Notes Sucessor:The successor is 3RV2011-1EA10
Circuit breaker size S0 for motor protection CLASS 10 A-release 0.45...0.63 A Short-circuit release 8.2 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2011-0GA15<< Notes Sucessor:The successor is 3RV2011-0GA15
Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.1...1.6 A N-release 21 A Screw terminal Standard switching capacity
Circuit breaker size S3 for motor protection, CLASS 10 A-release 22...32 A N-release 416 A Screw terminal increased switching capacity
Circuit breaker size S0 for motor protection CLASS 10 A-release 20...25 A Short-circuit release 325 A Screw terminal Standard switching capacity !!! Phased-out product !!! Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2021-4DA10<< Notes Sucessor:The successor is 3RV2021-4DA10
Power contactor, AC-3 50 A, 22 kW / 400 V 400 V AC, 50 Hz / 60 Hz, 440 V, 60 Hz, 3-pole, Size S2, screw terminal
65MM TERMINAL MODULE FOR ET200S HIGH FEATURE LINE STARTER/LINE DIR.STARTER- STARTER WITH SUPPLY CONNECTOR