Filters
Best selling products
22918 products
interface converter Phased-out product !!! For further information, please contact our sales department 24 V AC/DC, 3-way separation input: 0-20 mA output: 0-20 mA screw terminal
Temperature monitoring relay Thermocouple J,K, T,E, N,S, R,B 2 threshold values digitally adjustable -99 °C to 1800 °C (sensor-dependent) 24 V AC/DC 2 x 1 CO + 1 NO, Width 45 mm screw terminal
Temperature monitoring relay Thermocouple J, T, E, K, N 2 threshold values digitally adjustable -99 °C to 999 °C 24 - 240 V AC/DC 2 x 1 CO + 1 NO, Width 45 mm Spring-type terminal
Temperature monitoring relay Thermocouple type J, overshoot 2 threshold values, Width 22.5 mm 0 °C to 600 °C 24 - 240 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal
Temperature monitoring relay Thermocouple type J, overshoot 2 threshold values, Width 22.5 mm 0 C to 600 C 24 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal
Temperature monitoring relay Pt100, Undershoot 2 threshold values, Width 22.5 mm -50 °C to 50 °C 24 - 240 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal
Temperature monitoring relay PT100, Overshoot 2 threshold values, Width 22.5 mm 0 C to 100 C 24 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal
Monitoring relay, can be mounted to Contactor 3RT2, Size S0 standard, digitally adjustable Apparant/active current monitoring 4...40 A, 20...400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min spring-type connection system
Monitoring relay, can be mounted to Contactor 3RT2, Size S00 standard, digitally adjustable Apparant/active current monitoring 1.6-16 A, 20-400 Hz, 3-phase Supply 24-240 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min Screw connection system
Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment Apparent current monitoring 1.6-16 A, 20-400 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system
Output coupler Optocoupler 1 S, transistor, 24 V DC Output max. 30 V DC, 5 A Short circuit-proof Screw terminal Overall width 6.2 mm Thermal current 5 A
Timing relay, Multifunction Phased-out product !!! For further information, please contact our sales department Spring-type terminal 1 NO contact, delayed 1 NO contact, instantaneous 3 s...60 s 24 V AC/DC 100-127 V AC at 50/60 Hz AC
Timing relay, electronic Phased-out product !!! For further information, please contact our sales department with star-delta (wye-delta) function 1 NO contact, delayed 1 NO contact, instantaneous 1 time range 3...60 s 24 V AC/DC and 100...127 V AC at 50/60 Hz AC screw terminal
Timing relay, Multifunction Phased-out product !!! For further information, please contact our sales department Spring-type terminal 1 NO contact, delayed 1 NO contact instantaneous 1 time range 1...20 s 24 V AC/DC, 200-240 V AC at 50/60 Hz AC
Timing relay, Processor basis Phased-out product !!! For further information, please contact our sales department OFF delay 2 change-over contacts, without auxiliary voltage 0.05 s...600 s, 200-240 V AC/DC Spring-type terminal
Timing relay, Multifunction Phased-out product !!! For further information, please contact our sales department 2 change-over contacts, 16 functions 15 time ranges (0.05 s-100 h) 24 V, 100-127 V AC and 24 V DC at 50/60 Hz AC with LED, Screw terminal
Timing relay, Multifunction Phased-out product !!! For further information, please contact our sales department 1 change-over contact, 8 functions 15 time ranges (0.05 s-100 h) 24 V, 100-127 V AC and 24 V DC at 50/60 Hz AC with LED, Screw terminal
The preferred successor is 3RN2023-2DW30 Thermistor motor protection for 2 sensor circuits Warning and switching-off 1 NO + 1 CO, 24-240 V AC/DC
Thermistor motor protection for 2 sensor circuits Warning and switching-off 1 NO + 1 CO, 24-240 V AC/DC
!!! Phased-out product !!! The preferred successor is 3RN2013-2BW30 Thermistor motor protection Multifunctional evaluation unit Manual/Auto/Remote Short-circuit detection, 2 CO
Motor starter SIRIUS 3RM1 Reversing starter SAFETY 500 V; 1.6 - 7.0 A; 24 V DC Control circuit push-in Main circuit screw terminal
Motor starter SIRIUS 3RM1 Reversing starter SAFETY 500 V; 1.6 - 7.0 A; 24 V DC Push-in connection method
Motor starter SIRIUS 3RM1 Reversing starter 500 V; 0.4-2.0 A; 24 V DC Push-in connection method
CJ1 Position control module w/EtherCAT interface, 4 axes, servo control, 55 deg at 460 mA max at 5/DC
Filters