Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 75 kW
(400 V) 132 kW
(500 V) 160 kW
(230 V) 75 kW
(400 V) 132 kW
(500 V) 160 kW
250 A
at 230 V 132 kW
at 400 V 220 kW
at 500 V 295 kW
at 230 V 132 kW
at 400 V 220 kW
at 500 V 295 kW
430 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 10.2 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX250
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 75 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 200 Hp
(550 ... 600 V AC) Three Phase 250 Hp
(200 ... 208 V AC) Three Phase 75 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 200 Hp
(550 ... 600 V AC) Three Phase 250 Hp
Main Circuit 600 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501542
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 90 kW
(400 V) 160 kW
(500 V) 200 kW
(230 V) 90 kW
(400 V) 160 kW
(500 V) 200 kW
300 A
at 230 V 160 kW
at 400 V 257 kW
at 500 V 355 kW
at 230 V 160 kW
at 400 V 257 kW
at 500 V 355 kW
515 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
30 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 10.2 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX300
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 100 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 250 Hp
(550 ... 600 V AC) Three Phase 300 Hp
(200 ... 208 V AC) Three Phase 100 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 250 Hp
(550 ... 600 V AC) Three Phase 300 Hp
Main Circuit 600 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501474
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 110 kW
(400 V) 200 kW
(500 V) 257 kW
(230 V) 110 kW
(400 V) 200 kW
(500 V) 257 kW
370 A
at 230 V 200 kW
at 400 V 355 kW
at 500 V 450 kW
at 230 V 200 kW
at 400 V 355 kW
at 500 V 450 kW
640 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX370
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 150 Hp
(440 ... 480 V AC) Three Phase 300 Hp
(550 ... 600 V AC) Three Phase 350 Hp
(200 ... 208 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 150 Hp
(440 ... 480 V AC) Three Phase 300 Hp
(550 ... 600 V AC) Three Phase 350 Hp
Main Circuit 600 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501535
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
361 mm
493 mm
282 mm
25 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 132 kW
(400 V) 250 kW
(500 V) 315 kW
(230 V) 132 kW
(400 V) 250 kW
(500 V) 315 kW
470 A
at 230 V 250 kW
at 400 V 450 kW
at 500 V 600 kW
at 230 V 250 kW
at 400 V 450 kW
at 500 V 600 kW
814 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
Yes
Yes
Yes
Yes
Yes
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 35 N·m
PSTX470
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 150 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 400 Hp
(550 ... 600 V AC) Three Phase 500 Hp
(200 ... 208 V AC) Three Phase 150 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 400 Hp
(550 ... 600 V AC) Three Phase 500 Hp
Main Circuit 600 V
Main Circuit 309.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
470 mm
381 mm
650 mm
29 kg
7320500508954
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
361 mm
493 mm
282 mm
27 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 160 kW
(400 V) 315 kW
(500 V) 400 kW
(230 V) 160 kW
(400 V) 315 kW
(500 V) 400 kW
570 A
at 230 V 295 kW
at 400 V 540 kW
at 500 V 700 kW
at 230 V 295 kW
at 400 V 540 kW
at 500 V 700 kW
987 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
Yes
Yes
Yes
Yes
Yes
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 35 N·m
PSTX570
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 200 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 500 Hp
(550 ... 600 V AC) Three Phase 600 Hp
(200 ... 208 V AC) Three Phase 200 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 500 Hp
(550 ... 600 V AC) Three Phase 600 Hp
Main Circuit 600 V
Main Circuit 309.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
470 mm
381 mm
650 mm
31 kg
7320500508992
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
493 mm
369 mm
46.5 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 250 kW
(400 V) 450 kW
(500 V) 600 kW
(230 V) 250 kW
(400 V) 450 kW
(500 V) 600 kW
840 A
at 230 V 450 kW
at 400 V 800 kW
at 500 V 1000 kW
at 230 V 450 kW
at 400 V 800 kW
at 500 V 1000 kW
1455 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 V
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX840
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 300 Hp
(220 ... 240 V AC) Three Phase 350 Hp
(440 ... 480 V AC) Three Phase 700 Hp
(550 ... 600 V AC) Three Phase 800 Hp
(200 ... 208 V AC) Three Phase 300 Hp
(220 ... 240 V AC) Three Phase 350 Hp
(440 ... 480 V AC) Three Phase 700 Hp
(550 ... 600 V AC) Three Phase 800 Hp
Main Circuit 600 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
58.5 kg
7320500510421
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
515 mm
367 mm
62.3 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
1050 A
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
1810 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX1050
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
Main Circuit 600 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
4. Large Equipment (Any External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
74.3 kg
7320500510445
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
565 mm
367 mm
63.3 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
1250 A
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
2160 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX1250
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
Main Circuit 600 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
4. Large Equipment (Any External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
75.3 kg
7320500510469
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.6 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
(690 V) 25 kW
(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
(690 V) 25 kW
30 A
at 230 V 12.5 kW
at 400 V 25 kW
at 500 V 30 kW
at 690 V 45 kW
at 230 V 12.5 kW
at 400 V 25 kW
at 500 V 30 kW
at 690 V 45 kW
52 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX30
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
46ee42b5-0784-4f84-a200-fba43f921301 China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.6 kg
7320500501382
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.6 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 9 kW
(400 V) 18.5 kW
(500 V) 22 kW
(690 V) 30 kW
(230 V) 9 kW
(400 V) 18.5 kW
(500 V) 22 kW
(690 V) 30 kW
37 A
at 230 V 15 kW
at 400 V 30 kW
at 500 V 37 kW
at 690 V 55 kW
at 230 V 15 kW
at 400 V 30 kW
at 500 V 37 kW
at 690 V 55 kW
64 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX37
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 25 Hp
(550 ... 600 V AC) Three Phase 30 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
46ee42b5-0784-4f84-a200-fba43f921301 China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.6 kg
7320500501429
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.6 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 12.5 kW
(400 V) 22 kW
(500 V) 25 kW
(690 V) 37 kW
(230 V) 12.5 kW
(400 V) 22 kW
(500 V) 25 kW
(690 V) 37 kW
45 A
at 230 V 25 kW
at 400 V 37 kW
at 500 V 45 kW
at 690 V 59 kW
at 230 V 25 kW
at 400 V 37 kW
at 500 V 45 kW
at 690 V 59 kW
76 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX45
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
e1fe3351-a6ac-4cbd-aebf-814f3a66a5bc China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.6 kg
7320500501412
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.6 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 15 kW
(400 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
(230 V) 15 kW
(400 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
60 A
at 230 V 30 kW
at 400 V 55 kW
at 500 V 75 kW
at 690 V 90 kW
at 230 V 30 kW
at 400 V 55 kW
at 500 V 75 kW
at 690 V 90 kW
105 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX60
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
d1eab0cb-c4c6-4233-8fa0-1a9d9a9b7de8 China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.6 kg
7320500501375
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.7 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 18.5 kW
(400 V) 37 kW
(500 V) 45 kW
(690 V) 59 kW
(230 V) 18.5 kW
(400 V) 37 kW
(500 V) 45 kW
(690 V) 59 kW
72 A
at 230 V 37 kW
at 400 V 59 kW
at 500 V 80 kW
at 690 V 110 kW
at 230 V 37 kW
at 400 V 59 kW
at 500 V 80 kW
at 690 V 110 kW
124 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX72
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 ... 208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
ac10f14a-1b4e-426d-af4a-2e5fd406051c China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.7 kg
7320500501399
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.7 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 22 kW
(400 V) 45 kW
(500 V) 55 kW
(690 V) 75 kW
(230 V) 22 kW
(400 V) 45 kW
(500 V) 55 kW
(690 V) 75 kW
85 A
at 230 V 40 kW
at 400 V 75 kW
at 500 V 90 kW
at 690 V 132 kW
at 230 V 40 kW
at 400 V 75 kW
at 500 V 90 kW
at 690 V 132 kW
147 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX85
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
(200 ... 208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
f3a0566c-5aad-4ac9-94d0-4c2d5492623c China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.7 kg
7320500501351
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.7 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 30 kW
(400 V) 55 kW
(500 V) 75 kW
(690 V) 90 kW
(230 V) 30 kW
(400 V) 55 kW
(500 V) 75 kW
(690 V) 90 kW
105 A
at 230 V 55 kW
at 400 V 90 kW
at 500 V 110 kW
at 690 V 160 kW
at 230 V 55 kW
at 400 V 90 kW
at 500 V 110 kW
at 690 V 160 kW
181 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX105
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
Main Circuit 690 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
e7940dd6-ebdc-421a-ac15-6f53c066ab8e Sweden
0b26b9b3-1b09-4bda-808b-1c558c375102 Portugal
0ecd87f6-0b3d-4907-8e10-b07e53cce57a Greece
0ff651df-9e2c-4fd7-b1e3-7cdaed08d236 Estonia
185e87bb-a37a-47ec-bd3d-a49bd77cbe1f Belgium
26dbf795-797e-4169-9759-e7ad5374af6a Sweden
28ddc28d-3da5-43e8-94da-a1fef8c1eab9 Germany
2ac451b5-ed1c-4476-9960-5ffabd9a0512 Finland
32f62b4f-95d7-4d73-aff3-62825836cebe Norway
3bed07d0-3bb9-44af-a139-581d61ebcd55 Hungary
42618e39-7d5c-43e9-9c94-b18398113682 Poland
4b0c1e22-8250-42b2-85b2-2be2b3907126 Germany
53f68d24-5dc7-4aed-be25-6a92d43375e7 Germany
58568401-1ee5-4bda-92b9-97e38b7e9aee Hungary
7cd4d1f3-bb06-450b-b35d-875203c7f72d France
8697daae-e634-4686-a21d-36ea2c0dac72 Czech Republic
8777ac81-e4a5-4d81-8368-c11520219b5a Germany
8ef52d23-dd29-4c2b-8238-e3befec6b35f Poland
8f2933a9-0358-42b9-976b-1823cdc5cecc Bulgaria
9615b811-0bd3-4002-9062-d525714c5595 Croatia
a8593dc1-700a-43cd-8208-68e0d6de8729 France
ba0882b5-3f8d-416f-b004-0428942396a0 Denmark
bfbd2c7e-2d98-4400-8a70-755f22a45b45 Spain
c780222a-3d86-4656-bd30-fa6943426d29 Belgium
d9ebb58f-6b81-4c30-aa3f-99a3694286dd Italy
ed181487-611b-4185-8e13-39630ba2d6c0 Netherlands
ed52b8d9-4f83-4b16-ab5b-c14b8acb3935 Germany
ee24cbb2-bc7b-487d-8c7d-25111e9ddb8b Poland
0b26b9b3-1b09-4bda-808b-1c558c375102 Portugal
0ecd87f6-0b3d-4907-8e10-b07e53cce57a Greece
0ff651df-9e2c-4fd7-b1e3-7cdaed08d236 Estonia
185e87bb-a37a-47ec-bd3d-a49bd77cbe1f Belgium
26dbf795-797e-4169-9759-e7ad5374af6a Sweden
28ddc28d-3da5-43e8-94da-a1fef8c1eab9 Germany
2ac451b5-ed1c-4476-9960-5ffabd9a0512 Finland
32f62b4f-95d7-4d73-aff3-62825836cebe Norway
3bed07d0-3bb9-44af-a139-581d61ebcd55 Hungary
42618e39-7d5c-43e9-9c94-b18398113682 Poland
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.7 kg
7320500501344
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
199 mm
377 mm
283 mm
7 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
142 A
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
245 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 14 N·m
PSTX142
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
Main Circuit 690 V
Main Circuit 123.9
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
7f3a5266-46a0-4bd5-8956-4cb28cf71584 France
86667217-7850-4464-bc67-0989310e6d51 Belgium
8945c0b2-d687-4890-84ec-bfd8b63a6873 Belgium
8de00583-51c1-4c15-921d-cf224e8d6a7b Greece
95cdfb74-c4de-43c9-a407-a32f70a6bc98 Poland
99ee119e-fa5f-497c-961a-89051ecf6b00 Poland
b797e4b8-7518-46e0-ab6f-0e4d1c2aa87a Germany
bf3d4a73-1b3c-451a-b266-236ba7136eed Hungary
c0ef8ad3-55b8-4056-8a87-a33727de619c France
c6ec4ad1-bc67-4e74-b1bd-5e37556b8b4e Norway
c7da1248-c80a-4811-a6a8-195c040a4df8 Sweden
c83eb676-1ff4-412a-af63-9f6fe9b3a126 Poland
c93a6f14-01b7-4e10-8eaf-7b935d98e077 Germany
d0f38e66-e5ff-4c69-a6b4-db6ed0a1dc9b Netherlands
d236d276-4f52-41a5-aad1-8b8367bd7a2b Portugal
de94f801-93d2-454f-b5a5-8d39e3193292 Spain
fa967b40-4d4f-4609-80c5-d1098a8f5331 Hungary
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
263 mm
323 mm
454 mm
8.7 kg
7320500501450
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
199 mm
377 mm
283 mm
8.9 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 45 kW
(400 V) 90 kW
(500 V) 110 kW
(690 V) 160 kW
(230 V) 45 kW
(400 V) 90 kW
(500 V) 110 kW
(690 V) 160 kW
170 A
at 230 V 90 kW
at 400 V 160 kW
at 500 V 200 kW
at 690 V 257 kW
at 230 V 90 kW
at 400 V 160 kW
at 500 V 200 kW
at 690 V 257 kW
300 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 14 N·m
PSTX170
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 50 Hp
(220 ... 240 V AC) Three Phase 60 Hp
(440 ... 480 V AC) Three Phase 125 Hp
(550 ... 600 V AC) Three Phase 150 Hp
(200 ... 208 V AC) Three Phase 50 Hp
(220 ... 240 V AC) Three Phase 60 Hp
(440 ... 480 V AC) Three Phase 125 Hp
(550 ... 600 V AC) Three Phase 150 Hp
Main Circuit 690 V
Main Circuit 123.9
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
263 mm
323 mm
454 mm
10.4 kg
7320500501443
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
13.3 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 59 kW
(400 V) 110 kW
(500 V) 132 kW
(690 V) 184 kW
(230 V) 59 kW
(400 V) 110 kW
(500 V) 132 kW
(690 V) 184 kW
210 A
at 230 V 102 kW
at 400 V 184 kW
at 500 V 250 kW
at 690 V 315 kW
at 230 V 102 kW
at 400 V 184 kW
at 500 V 250 kW
at 690 V 315 kW
360 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 10.2 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX210
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 60 Hp
(220 ... 240 V AC) Three Phase 75 Hp
(440 ... 480 V AC) Three Phase 150 Hp
(550 ... 600 V AC) Three Phase 200 Hp
(200 ... 208 V AC) Three Phase 60 Hp
(220 ... 240 V AC) Three Phase 75 Hp
(440 ... 480 V AC) Three Phase 150 Hp
(550 ... 600 V AC) Three Phase 200 Hp
Main Circuit 690 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
16.3 kg
7320500501528
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 75 kW
(400 V) 132 kW
(500 V) 160 kW
(690 V) 220 kW
(230 V) 75 kW
(400 V) 132 kW
(500 V) 160 kW
(690 V) 220 kW
250 A
at 230 V 132 kW
at 400 V 220 kW
at 500 V 295 kW
at 690 V 400 kW
at 230 V 132 kW
at 400 V 220 kW
at 500 V 295 kW
at 690 V 400 kW
430 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX250
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 75 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 200 Hp
(550 ... 600 V AC) Three Phase 250 Hp
(200 ... 208 V AC) Three Phase 75 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 200 Hp
(550 ... 600 V AC) Three Phase 250 Hp
Main Circuit 690 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501511
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 90 kW
(400 V) 160 kW
(500 V) 200 kW
(690 V) 257 kW
(230 V) 90 kW
(400 V) 160 kW
(500 V) 200 kW
(690 V) 257 kW
300 A
at 230 V 160 kW
at 400 V 257 kW
at 500 V 355 kW
at 690 V 500 kW
at 230 V 160 kW
at 400 V 257 kW
at 500 V 355 kW
at 690 V 500 kW
515 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX300
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 100 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 250 Hp
(550 ... 600 V AC) Three Phase 300 Hp
(200 ... 208 V AC) Three Phase 100 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 250 Hp
(550 ... 600 V AC) Three Phase 300 Hp
Main Circuit 690 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501481
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
258 mm
470 mm
279 mm
15.5 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 110 kW
(400 V) 200 kW
(500 V) 257 kW
(690 V) 355 kW
(230 V) 110 kW
(400 V) 200 kW
(500 V) 257 kW
(690 V) 355 kW
370 A
at 230 V 200 kW
at 400 V 355 kW
at 500 V 450 kW
at 690 V 600 kW
at 230 V 200 kW
at 400 V 355 kW
at 500 V 450 kW
at 690 V 600 kW
640 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Hole Diameter 10.2 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 25 N·m
PSTX370
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 150 Hp
(440 ... 480 V AC) Three Phase 300 Hp
(550 ... 600 V AC) Three Phase 350 Hp
(200 ... 208 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 150 Hp
(440 ... 480 V AC) Three Phase 300 Hp
(550 ... 600 V AC) Three Phase 350 Hp
Main Circuit 690 V
Main Circuit 221.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
352 mm
379 mm
564 mm
18.5 kg
7320500501498
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
361 mm
493 mm
282 mm
25 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 132 kW
(400 V) 250 kW
(500 V) 315 kW
(690 V) 450 kW
(230 V) 132 kW
(400 V) 250 kW
(500 V) 315 kW
(690 V) 450 kW
470 A
at 230 V 250 kW
at 400 V 450 kW
at 500 V 600 kW
at 690 V 800 kW
at 230 V 250 kW
at 400 V 450 kW
at 500 V 600 kW
at 690 V 800 kW
814 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
Yes
Yes
Yes
Yes
Yes
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 35 N·m
PSTX470
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 150 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 400 Hp
(550 ... 600 V AC) Three Phase 500 Hp
(200 ... 208 V AC) Three Phase 150 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 400 Hp
(550 ... 600 V AC) Three Phase 500 Hp
Main Circuit 690 V
Main Circuit 309.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
470 mm
381 mm
650 mm
29 kg
7320500508985
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
361 mm
493 mm
282 mm
27 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 160 kW
(400 V) 315 kW
(500 V) 400 kW
(690 V) 560 kW
(230 V) 160 kW
(400 V) 315 kW
(500 V) 400 kW
(690 V) 560 kW
570 A
at 230 V 295 kW
at 400 V 540 kW
at 500 V 700 kW
at 690 V 960 kW
at 230 V 295 kW
at 400 V 540 kW
at 500 V 700 kW
at 690 V 960 kW
987 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
Yes
Yes
Yes
Yes
Yes
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 35 N·m
PSTX570
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 200 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 500 Hp
(550 ... 600 V AC) Three Phase 600 Hp
(200 ... 208 V AC) Three Phase 200 Hp
(220 ... 240 V AC) Three Phase 200 Hp
(440 ... 480 V AC) Three Phase 500 Hp
(550 ... 600 V AC) Three Phase 600 Hp
Main Circuit 690 V
Main Circuit 309.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
470 mm
381 mm
650 mm
31 kg
7320500508978
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
493 mm
369 mm
46.5 kg
Technical
208 ... 690 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 200 kW
(400 V) 400 kW
(500 V) 500 kW
(690 V) 710 kW
(230 V) 200 kW
(400 V) 400 kW
(500 V) 500 kW
(690 V) 710 kW
720 A
at 230 V 355 kW
at 400 V 710 kW
at 500 V 880 kW
at 690 V 1200 kW
at 230 V 355 kW
at 400 V 710 kW
at 500 V 880 kW
at 690 V 1200 kW
1247 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX720
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 250 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
(200 ... 208 V AC) Three Phase 250 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
Main Circuit 690 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
58.5 kg
7320500510407
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter
ABB industrial PLCs are the ultimate solution for modern businesses striving for efficiency, productivity, and unparalleled control. As a business owner, you know that every operation demands precision, consistency, and absolute reliability. That's why the brand has developed a powerful tool that will revolutionize the way you manage your industrial processes. With ABB PLCs, you'll unlock a world of limitless possibilities. Their cutting-edge technology ensures seamless integration, allowing you to effortlessly streamline your manufacturing operations. Say goodbye to the days of complicated manual controls and labor-intensive processes—these industrial PLC systems are here to simplify your operations and supercharge your business.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.
We at PLC Direct understand that you can’t rely on just any automation equipment to keep your facilities operating at their best. That’s why we make sure that we only feature products from top brands in our inventory. Whether you’re running a current ABB PLC model or an older one, we carry compatible replacements and parts to keep things moving smoothly. Shop with us today to find the perfect industrial PLC for your needs.