SD326RU68S2 Schneider

Main

Characteristic Value(s)
Range of Product Lexium SD3
Product or Component Type Motion stepper drive
Device short name SD326
Supply voltage limits 100…120 V
200…240 V

Complementary

Characteristic Value(s)
Format of the drive Block
Phase Single phase
[Us] rated supply voltage 100...120 V - 15...10 %
200...230 V - 15...10 %
Supply voltage type AC/DC
Network frequency limits 50…60 Hz - 15...10 %)
Communication interface Pulse/direction, Integrated
Function Available Rotation monitoring
Holding brake monitoring
Maximum motor phase current 6.8 A
Current consumption <= 0.2 mA 24 V control voltage
Nominal power 280 W 115 V
420 W 230 V
Short-circuit current 0.5 kA
Associated fuse rating 10 A 115 V
6 A 230 V
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA IEC 60990-3
Voltage state 0 guaranteed <= 5 V 24 V optocoupler input signals
<= 0.5 V 5 V optocoupler input signals
Voltage state 1 guaranteed 15...30 V 24 V optocoupler input signals
2.5...5.25 V 5 V optocoupler input signals
Input current 25 mA 5 V optocoupler input signals
7 mA 24 V optocoupler input signals
Maximum input frequency 200 kHz 24 V optocoupler input signals
200 kHz 5 V optocoupler input signals
400 kHz ENC_A/ENC_B signal input
Maximum switching voltage 30 V DC readiness signal output)
Maximum switching current 200 mA readiness signal output)
50 mA 24 V output signals)RM-FAULT_OUT
1.7 mA 24 V output signals)+BRAKE_OUT
Maximum voltage drop <1 V 50 mA load 24 V output signals
<1 V 50 mA load ENC+5V_OUT signal output
<1 V 50 mA load readiness signal output
Physical interface RS422 - ENC_A/ENC_B signal input
Output voltage <= 30 V 24 V output signals)
4.75...5.25 V ENC+5V_OUT signal output)
Input voltage 24 V -15 %/+20 % 24 V control voltage
Residual ripple <= 5 % 24 V control voltage)
type of cooling Fan
Maximum mechanical speed 3000 rpm
Height 5.7 in (145 mm)
Width 2.8 in (72 mm)
Depth 5.5 in (140 mm)
Shock resistance 15 gn 11 ms IEC 60068-2-27
Product Weight 2.6 lb(US) (1.2 kg)
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price18,930.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
0.00 kr
18,930.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Main

Characteristic Value(s)
Range of Product Lexium SD3
Product or Component Type Motion stepper drive
Device short name SD326
Supply voltage limits 100…120 V
200…240 V

Complementary

Characteristic Value(s)
Format of the drive Block
Phase Single phase
[Us] rated supply voltage 100...120 V - 15...10 %
200...230 V - 15...10 %
Supply voltage type AC/DC
Network frequency limits 50…60 Hz - 15...10 %)
Communication interface Pulse/direction, Integrated
Function Available Rotation monitoring
Holding brake monitoring
Maximum motor phase current 6.8 A
Current consumption <= 0.2 mA 24 V control voltage
Nominal power 280 W 115 V
420 W 230 V
Short-circuit current 0.5 kA
Associated fuse rating 10 A 115 V
6 A 230 V
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA IEC 60990-3
Voltage state 0 guaranteed <= 5 V 24 V optocoupler input signals
<= 0.5 V 5 V optocoupler input signals
Voltage state 1 guaranteed 15...30 V 24 V optocoupler input signals
2.5...5.25 V 5 V optocoupler input signals
Input current 25 mA 5 V optocoupler input signals
7 mA 24 V optocoupler input signals
Maximum input frequency 200 kHz 24 V optocoupler input signals
200 kHz 5 V optocoupler input signals
400 kHz ENC_A/ENC_B signal input
Maximum switching voltage 30 V DC readiness signal output)
Maximum switching current 200 mA readiness signal output)
50 mA 24 V output signals)RM-FAULT_OUT
1.7 mA 24 V output signals)+BRAKE_OUT
Maximum voltage drop <1 V 50 mA load 24 V output signals
<1 V 50 mA load ENC+5V_OUT signal output
<1 V 50 mA load readiness signal output
Physical interface RS422 - ENC_A/ENC_B signal input
Output voltage <= 30 V 24 V output signals)
4.75...5.25 V ENC+5V_OUT signal output)
Input voltage 24 V -15 %/+20 % 24 V control voltage
Residual ripple <= 5 % 24 V control voltage)
type of cooling Fan
Maximum mechanical speed 3000 rpm
Height 5.7 in (145 mm)
Width 2.8 in (72 mm)
Depth 5.5 in (140 mm)
Shock resistance 15 gn 11 ms IEC 60068-2-27
Product Weight 2.6 lb(US) (1.2 kg)
Characteristic Value(s)
Format of the drive Block
Phase Single phase
[Us] rated supply voltage 100...120 V - 15...10 %
200...230 V - 15...10 %
Supply voltage type AC/DC
Network frequency limits 50…60 Hz - 15...10 %)
Communication interface Pulse/direction, Integrated
Function Available Rotation monitoring
Holding brake monitoring
Maximum motor phase current 6.8 A
Current consumption <= 0.2 mA 24 V control voltage
Nominal power 280 W 115 V
420 W 230 V
Short-circuit current 0.5 kA
Associated fuse rating 10 A 115 V
6 A 230 V
Overvoltage category III
Inrush current 60 A
Maximum leakage current 30 mA IEC 60990-3
Voltage state 0 guaranteed <= 5 V 24 V optocoupler input signals
<= 0.5 V 5 V optocoupler input signals
Voltage state 1 guaranteed 15...30 V 24 V optocoupler input signals
2.5...5.25 V 5 V optocoupler input signals
Input current 25 mA 5 V optocoupler input signals
7 mA 24 V optocoupler input signals
Maximum input frequency 200 kHz 24 V optocoupler input signals
200 kHz 5 V optocoupler input signals
400 kHz ENC_A/ENC_B signal input
Maximum switching voltage 30 V DC readiness signal output)
Maximum switching current 200 mA readiness signal output)
50 mA 24 V output signals)RM-FAULT_OUT
1.7 mA 24 V output signals)+BRAKE_OUT
Maximum voltage drop <1 V 50 mA load 24 V output signals
<1 V 50 mA load ENC+5V_OUT signal output
<1 V 50 mA load readiness signal output
Physical interface RS422 - ENC_A/ENC_B signal input
Output voltage <= 30 V 24 V output signals)
4.75...5.25 V ENC+5V_OUT signal output)
Input voltage 24 V -15 %/+20 % 24 V control voltage
Residual ripple <= 5 % 24 V control voltage)
type of cooling Fan
Maximum mechanical speed 3000 rpm
Height 5.7 in (145 mm)
Width 2.8 in (72 mm)
Depth 5.5 in (140 mm)
Shock resistance 15 gn 11 ms IEC 60068-2-27
Product Weight 2.6 lb(US) (1.2 kg)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator