PGA36120 Schneider

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Main

Characteristic Value(s)
Range PowerPact
product name PowerPact P
Product or Component Type Circuit breaker
Device Application Distribution

Complementary

Characteristic Value(s)
Line Rated Current 1200 A
Number of Poles 3P
Control Type Toggle
Breaking capacity code G
Breaking capacity AIR 65 kA 240 V AC 50/60 Hz UL 489
AIR 35 kA 480 V AC 50/60 Hz UL 489
AIR 18 kA 600 V AC 50/60 Hz UL 489
Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2
Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage 600 V AC 50/60 Hz UL 489
Network Frequency 50/60 Hz
[Ics] rated service breaking capacity 25 kA 240 V AC 50/60 Hz IEC 60947-2
20 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Trip unit technology Electronic, basic, ET 1.0I, I
Continuous current rating 80 %
[Ui] rated insulation voltage 750 V IEC 60947-2
Trip unit name ET 1.0I
AWG gauge 4 x AWG 3/0...500 kcmil aluminium/copper
Local signalling 1 trip indicator green)
Mounting mode I-Line bracket)
Mounting Support Bracket
Electrical connection I-Line connection, line
Lugs, load
Terminal identifier AL1200P25K
Long time pick-up adjustment range 1 In
Mounting Height 9 in (228.6 mm)
Tightening torque 442.5 lbf.in (50 N.m) 0.1…0.4 in² (95…240 mm²) (4 x AWG 3/0...500 kcmil)
8.9…11.5 lbf.in (1.0…1.3 N.m)
Number of slots 2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length 1.2 in (30 mm)
Height 16.16 in (410.46 mm)
Width 8.27 in (210.06 mm)
Depth 8.05 in (204.47 mm)
Product Weight 32 lb(US) (14.5 kg)
Quantity per Set 1
Phase connection ABC
Circuit breaker application HACR rated
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price152,531.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
0.00 kr
152,531.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Main

Characteristic Value(s)
Range PowerPact
product name PowerPact P
Product or Component Type Circuit breaker
Device Application Distribution

Complementary

Characteristic Value(s)
Line Rated Current 1200 A
Number of Poles 3P
Control Type Toggle
Breaking capacity code G
Breaking capacity AIR 65 kA 240 V AC 50/60 Hz UL 489
AIR 35 kA 480 V AC 50/60 Hz UL 489
AIR 18 kA 600 V AC 50/60 Hz UL 489
Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2
Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage 600 V AC 50/60 Hz UL 489
Network Frequency 50/60 Hz
[Ics] rated service breaking capacity 25 kA 240 V AC 50/60 Hz IEC 60947-2
20 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Trip unit technology Electronic, basic, ET 1.0I, I
Continuous current rating 80 %
[Ui] rated insulation voltage 750 V IEC 60947-2
Trip unit name ET 1.0I
AWG gauge 4 x AWG 3/0...500 kcmil aluminium/copper
Local signalling 1 trip indicator green)
Mounting mode I-Line bracket)
Mounting Support Bracket
Electrical connection I-Line connection, line
Lugs, load
Terminal identifier AL1200P25K
Long time pick-up adjustment range 1 In
Mounting Height 9 in (228.6 mm)
Tightening torque 442.5 lbf.in (50 N.m) 0.1…0.4 in² (95…240 mm²) (4 x AWG 3/0...500 kcmil)
8.9…11.5 lbf.in (1.0…1.3 N.m)
Number of slots 2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length 1.2 in (30 mm)
Height 16.16 in (410.46 mm)
Width 8.27 in (210.06 mm)
Depth 8.05 in (204.47 mm)
Product Weight 32 lb(US) (14.5 kg)
Quantity per Set 1
Phase connection ABC
Circuit breaker application HACR rated
Characteristic Value(s)
Line Rated Current 1200 A
Number of Poles 3P
Control Type Toggle
Breaking capacity code G
Breaking capacity AIR 65 kA 240 V AC 50/60 Hz UL 489
AIR 35 kA 480 V AC 50/60 Hz UL 489
AIR 18 kA 600 V AC 50/60 Hz UL 489
Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2
Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage 600 V AC 50/60 Hz UL 489
Network Frequency 50/60 Hz
[Ics] rated service breaking capacity 25 kA 240 V AC 50/60 Hz IEC 60947-2
20 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Trip unit technology Electronic, basic, ET 1.0I, I
Continuous current rating 80 %
[Ui] rated insulation voltage 750 V IEC 60947-2
Trip unit name ET 1.0I
AWG gauge 4 x AWG 3/0...500 kcmil aluminium/copper
Local signalling 1 trip indicator green)
Mounting mode I-Line bracket)
Mounting Support Bracket
Electrical connection I-Line connection, line
Lugs, load
Terminal identifier AL1200P25K
Long time pick-up adjustment range 1 In
Mounting Height 9 in (228.6 mm)
Tightening torque 442.5 lbf.in (50 N.m) 0.1…0.4 in² (95…240 mm²) (4 x AWG 3/0...500 kcmil)
8.9…11.5 lbf.in (1.0…1.3 N.m)
Number of slots 2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length 1.2 in (30 mm)
Height 16.16 in (410.46 mm)
Width 8.27 in (210.06 mm)
Depth 8.05 in (204.47 mm)
Product Weight 32 lb(US) (14.5 kg)
Quantity per Set 1
Phase connection ABC
Circuit breaker application HACR rated

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator