LV848073 Schneider Electric

Main

Characteristic Value(s)
Range MasterPacT
product name MasterPact MTZ2
Device short name MTZ2 25 H1
Product or component type Circuit breaker
Device application Power distribution protection
Poles description 4P
Neutral position Right
Control unit Without control unit
Product compatibility control unit MicroLogic 2.0 X
control unit MicroLogic 5.0 X
control unit MicroLogic 6.0 X
control unit MicroLogic 7.0 X
control unit MicroLogic 2.0 Xi
control unit MicroLogic 5.0 Xi
control unit MicroLogic 6.0 Xi
control unit MicroLogic 7.0 Xi
[In] rated current 2500 A at 40 °C
Performance type H1 66 kA 415 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
control type Push-button
Mounting mode Fixed

Complementary

Characteristic Value(s)
[Icu] rated ultimate short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 66 kA 0.5 s
66 kA 1 s
66 kA 3 s
[Icm] rated short-circuit making capacity 145 kA 220/415 V AC at 50/60 Hz
145 kA 440 V AC at 50/60 Hz
145 kA 500/525 V AC at 50/60 Hz
145 kA 660/690 V AC at 50/60 Hz
Sensor rating 1250 A
1600 A
2000 A
2500 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 260 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Rails
Base plate
Upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 20000 cycles with periodic preventive maintenance
Electrical durability AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height 352 mm
Width 537 mm
Depth 300 mm
Product weight 65 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme
Price on request
Ask for quote
   

Notify Me When Available

Main

Characteristic Value(s)
Range MasterPacT
product name MasterPact MTZ2
Device short name MTZ2 25 H1
Product or component type Circuit breaker
Device application Power distribution protection
Poles description 4P
Neutral position Right
Control unit Without control unit
Product compatibility control unit MicroLogic 2.0 X
control unit MicroLogic 5.0 X
control unit MicroLogic 6.0 X
control unit MicroLogic 7.0 X
control unit MicroLogic 2.0 Xi
control unit MicroLogic 5.0 Xi
control unit MicroLogic 6.0 Xi
control unit MicroLogic 7.0 Xi
[In] rated current 2500 A at 40 °C
Performance type H1 66 kA 415 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
control type Push-button
Mounting mode Fixed

Complementary

Characteristic Value(s)
[Icu] rated ultimate short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 66 kA 0.5 s
66 kA 1 s
66 kA 3 s
[Icm] rated short-circuit making capacity 145 kA 220/415 V AC at 50/60 Hz
145 kA 440 V AC at 50/60 Hz
145 kA 500/525 V AC at 50/60 Hz
145 kA 660/690 V AC at 50/60 Hz
Sensor rating 1250 A
1600 A
2000 A
2500 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 260 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Rails
Base plate
Upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 20000 cycles with periodic preventive maintenance
Electrical durability AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height 352 mm
Width 537 mm
Depth 300 mm
Product weight 65 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme
Characteristic Value(s)
[Icu] rated ultimate short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 66 kA 0.5 s
66 kA 1 s
66 kA 3 s
[Icm] rated short-circuit making capacity 145 kA 220/415 V AC at 50/60 Hz
145 kA 440 V AC at 50/60 Hz
145 kA 500/525 V AC at 50/60 Hz
145 kA 660/690 V AC at 50/60 Hz
Sensor rating 1250 A
1600 A
2000 A
2500 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 260 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Rails
Base plate
Upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 20000 cycles with periodic preventive maintenance
Electrical durability AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height 352 mm
Width 537 mm
Depth 300 mm
Product weight 65 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator