LJ-S040 Keyence

Specifications

Model

LJ-S040

Reference distance

70 mm 2.76" *1

Measurement range

Z-axis (height)

±18 mm ±0.71" (F.S.=36 mm 1.42")

X-axis (width)

NEAR side

31 mm 1.22"

Reference distance

35 mm 1.38"

FAR side

39 mm 1.54"

Y-axis

Reference distance

80 mm 3.15"

XY data interval

12.5 μm 0.0005"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.5 μm 0.000020" *4

XY (distance)

1 μm 0.000039" *5

Linearity

Standard area

±0.02% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price361,227.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
0.00 kr
361,227.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

LJ-S040

Reference distance

70 mm 2.76" *1

Measurement range

Z-axis (height)

±18 mm ±0.71" (F.S.=36 mm 1.42")

X-axis (width)

NEAR side

31 mm 1.22"

Reference distance

35 mm 1.38"

FAR side

39 mm 1.54"

Y-axis

Reference distance

80 mm 3.15"

XY data interval

12.5 μm 0.0005"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.5 μm 0.000020" *4

XY (distance)

1 μm 0.000039" *5

Linearity

Standard area

±0.02% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

Model

LJ-S040

Reference distance

70 mm 2.76" *1

Measurement range

Z-axis (height)

±18 mm ±0.71" (F.S.=36 mm 1.42")

X-axis (width)

NEAR side

31 mm 1.22"

Reference distance

35 mm 1.38"

FAR side

39 mm 1.54"

Y-axis

Reference distance

80 mm 3.15"

XY data interval

12.5 μm 0.0005"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.5 μm 0.000020" *4

XY (distance)

1 μm 0.000039" *5

Linearity

Standard area

±0.02% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator