KV-XL202 Keyence

Specifications

Model

KV-XL202

Type

Serial communication unit

Communication standard

RS-232C

Connection interface

European terminal block with 7 poles (detachable) × 2 ports

Transmission specifications

Electrical termination (terminator)

-

Transmission rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps

Transmission method

Full duplex

Data format

Start bit: 1 bit
Data bit: 7 bits, 8 bits
Stop bit: 1 bit, 2 bits

Error detection

Parity: Even, odd, none

RS/CS flow control

ON or OFF

Transmission distance

15 m 49.2'

Number of transmission units

1

Connectable CPU unit

KV-X Series/KV-8000A

Refresh

Automatic refresh, direct refresh, inter-unit synchronization refresh

Serial communication functions

Non-procedure, PROTOCOL STUDIO, Modbus slave, etc.

Serial communication function execution methods

Ladder program, unit program (flow)

Unit program capacity

3 MB (Max. number of blocks: Approx. 20000)

flow

Max. number of flows

256

Number of simultaneous activities

Unlimited

Flow

Internal data Memory

524288 words

PROTOCOL STUDIO

Transmission method

Cyclic communication: Tx + Rx, Tx only, Rx only
Event communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx, Break Tx

Max. number of connected devices

2

Max. number of communication commands

48/96*1

Maximum number of total frames

Rx: 48/96*1 × 16;
Tx: 48/96*1 × 1

Max. number of compared received frames

16 per command

Maximum number of block elements

96 per frame

Transmission data length

1 to 2048 bytes per frame

Reception data length

PLC link

Communication patterns

Write, read, transfer

Number of link settings

512 settings max.*2

Link data size

1440 words max. per setting (bit: 720 words, word: 720 words)
737280 words max. (total) (1440 words × 512 settings)

Data unit

1 word

Number of connected models

2 models max. (1 model × 2 ports)

Number of connected units

2 max. (1 unit × 2 ports)

Trigger types

Cyclic/event (64 settings max. for event*2)

Update interval

10 to 65535 ms

Internal current consumption

140 mA or less

Weight

Approx. 200 g

*1 The max. is 48 when “Standard” is set for the number of communication commands in Unit Editor and 96 when “Extended” is set.
*2 Total for one KV-XL202/XL402 unit.

Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price10,616.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
0.00 kr
10,616.00 kr
4,669.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Specifications

Model

KV-XL202

Type

Serial communication unit

Communication standard

RS-232C

Connection interface

European terminal block with 7 poles (detachable) × 2 ports

Transmission specifications

Electrical termination (terminator)

-

Transmission rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps

Transmission method

Full duplex

Data format

Start bit: 1 bit
Data bit: 7 bits, 8 bits
Stop bit: 1 bit, 2 bits

Error detection

Parity: Even, odd, none

RS/CS flow control

ON or OFF

Transmission distance

15 m 49.2'

Number of transmission units

1

Connectable CPU unit

KV-X Series/KV-8000A

Refresh

Automatic refresh, direct refresh, inter-unit synchronization refresh

Serial communication functions

Non-procedure, PROTOCOL STUDIO, Modbus slave, etc.

Serial communication function execution methods

Ladder program, unit program (flow)

Unit program capacity

3 MB (Max. number of blocks: Approx. 20000)

flow

Max. number of flows

256

Number of simultaneous activities

Unlimited

Flow

Internal data Memory

524288 words

PROTOCOL STUDIO

Transmission method

Cyclic communication: Tx + Rx, Tx only, Rx only
Event communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx, Break Tx

Max. number of connected devices

2

Max. number of communication commands

48/96*1

Maximum number of total frames

Rx: 48/96*1 × 16;
Tx: 48/96*1 × 1

Max. number of compared received frames

16 per command

Maximum number of block elements

96 per frame

Transmission data length

1 to 2048 bytes per frame

Reception data length

PLC link

Communication patterns

Write, read, transfer

Number of link settings

512 settings max.*2

Link data size

1440 words max. per setting (bit: 720 words, word: 720 words)
737280 words max. (total) (1440 words × 512 settings)

Data unit

1 word

Number of connected models

2 models max. (1 model × 2 ports)

Number of connected units

2 max. (1 unit × 2 ports)

Trigger types

Cyclic/event (64 settings max. for event*2)

Update interval

10 to 65535 ms

Internal current consumption

140 mA or less

Weight

Approx. 200 g

*1 The max. is 48 when “Standard” is set for the number of communication commands in Unit Editor and 96 when “Extended” is set.
*2 Total for one KV-XL202/XL402 unit.

Model

KV-XL202

Type

Serial communication unit

Communication standard

RS-232C

Connection interface

European terminal block with 7 poles (detachable) × 2 ports

Transmission specifications

Electrical termination (terminator)

-

Transmission rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps

Transmission method

Full duplex

Data format

Start bit: 1 bit
Data bit: 7 bits, 8 bits
Stop bit: 1 bit, 2 bits

Error detection

Parity: Even, odd, none

RS/CS flow control

ON or OFF

Transmission distance

15 m 49.2'

Number of transmission units

1

Connectable CPU unit

KV-X Series/KV-8000A

Refresh

Automatic refresh, direct refresh, inter-unit synchronization refresh

Serial communication functions

Non-procedure, PROTOCOL STUDIO, Modbus slave, etc.

Serial communication function execution methods

Ladder program, unit program (flow)

Unit program capacity

3 MB (Max. number of blocks: Approx. 20000)

flow

Max. number of flows

256

Number of simultaneous activities

Unlimited

Flow

Internal data Memory

524288 words

PROTOCOL STUDIO

Transmission method

Cyclic communication: Tx + Rx, Tx only, Rx only
Event communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx, Break Tx

Max. number of connected devices

2

Max. number of communication commands

48/96*1

Maximum number of total frames

Rx: 48/96*1 × 16;
Tx: 48/96*1 × 1

Max. number of compared received frames

16 per command

Maximum number of block elements

96 per frame

Transmission data length

1 to 2048 bytes per frame

Reception data length

PLC link

Communication patterns

Write, read, transfer

Number of link settings

512 settings max.*2

Link data size

1440 words max. per setting (bit: 720 words, word: 720 words)
737280 words max. (total) (1440 words × 512 settings)

Data unit

1 word

Number of connected models

2 models max. (1 model × 2 ports)

Number of connected units

2 max. (1 unit × 2 ports)

Trigger types

Cyclic/event (64 settings max. for event*2)

Update interval

10 to 65535 ms

Internal current consumption

140 mA or less

Weight

Approx. 200 g

*1 The max. is 48 when “Standard” is set for the number of communication commands in Unit Editor and 96 when “Extended” is set.
*2 Total for one KV-XL202/XL402 unit.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator