Keyence

GL-R52H Keyence

Specifications

Model

GL-R52H

Detection capability

ø0.98" ø25 mm

Total length

40.94" 1040mm

No. of beam

52

Detection height

40.16" 1020mm

Protection height

41.93" 1065mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

10

OFF→ON

53.9*2

All blocked→ON

77*3

Optical synchronization system
(Channel A or B)

ON→OFF

14.3

OFF→ON

60.3*2

All blocked→ON

94.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

69

Receiver

80

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1440 g

Receiver

1450 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.


Sale price10,391.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
10,391.00 kr
0.00 kr
5,582.00 kr

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Specifications

Model

GL-R52H

Detection capability

ø0.98" ø25 mm

Total length

40.94" 1040mm

No. of beam

52

Detection height

40.16" 1020mm

Protection height

41.93" 1065mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

10

OFF→ON

53.9*2

All blocked→ON

77*3

Optical synchronization system
(Channel A or B)

ON→OFF

14.3

OFF→ON

60.3*2

All blocked→ON

94.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

69

Receiver

80

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1440 g

Receiver

1450 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Specifications

Model

GL-R52H

Detection capability

ø0.98" ø25 mm

Total length

40.94" 1040mm

No. of beam

52

Detection height

40.16" 1020mm

Protection height

41.93" 1065mm

Beam axis spacing/Lens diameter

20 mm / ø5 0.79" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

10

OFF→ON

53.9*2

All blocked→ON

77*3

Optical synchronization system
(Channel A or B)

ON→OFF

14.3

OFF→ON

60.3*2

All blocked→ON

94.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

69

Receiver

80

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1440 g

Receiver

1450 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed