Keyence

FD-Q10C Keyence

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.


Sale price4,853.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
4,853.00 kr
3,913.00 kr
0.00 kr

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed