ATV930C16N4 Schneider Electric

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant Standard version
With braking chopper
Device Application Industrial Application
Product destination Synchronous motors
Asynchronous motors
Phase 3 phase
Single phase
Mounting Mode Wall mount
Continuous output current 302 A 4 kHz normal duty
250 A 4 kHz heavy duty
Communication Port Protocol Ethernet IP/Modbus TCP
Modbus
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 302.0 A
Motor power kW 160.0 kW normal duty
132.0 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Line side screw terminal 2 x 95...3 x 120 mm² 2 x AWG 3/0...2 x 300 kcmil
DC bus screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Local signalling Local diagnostic: 3 LEDs (mono/dual colour)
5 LEDs (dual colour)
2 LEDs (dual colour)
1 LED (red)
Isolation Between power and control terminals
Discrete input number 10
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
S, U or customized
Motor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
Switching frequency 1...8 kHz adjustable
2.5...8 kHz with derating factor
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 284.0 A 380 V normal duty)
237.0 A 380 V heavy duty)
262.0 A 480 V normal duty)
213.0 A 480 V heavy duty)
Maximum Input Current per Phase 284.0 A
Maximum output voltage 480.0 V
Apparent power 201.3 kVA 380...480 V normal duty)
161.4 kVA 380...480 V heavy duty)
Maximum transient current 362 A 60 s normal duty)
375 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 250.0 A
Base load current at low overload 302.0 A
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 12.6 in (320 mm)
Height 47.4 in (1205 mm)
Depth 15.5 in (393 mm)
Product Weight 229.3 lb(US) (104 kg)
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price73,418.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
73,418.00 kr
0.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Main

Characteristic Value(s)
Range of Product Altivar Process ATV900
Product Specific Application Process for industrial
Product or Component Type Variable speed drive
Variant Standard version
With braking chopper
Device Application Industrial Application
Product destination Synchronous motors
Asynchronous motors
Phase 3 phase
Single phase
Mounting Mode Wall mount
Continuous output current 302 A 4 kHz normal duty
250 A 4 kHz heavy duty
Communication Port Protocol Ethernet IP/Modbus TCP
Modbus
Option card Slot A communication module Profibus DP V1
Slot A communication module PROFINET
Slot A communication module DeviceNet
Slot A communication module EtherCAT
Slot A communication module CANopen daisy chain RJ45
Slot A communication module CANopen SUB-D 9
Slot A communication module CANopen screw terminals
Slot A/slot B/slot C digital and analog I/O extension module
Slot A/slot B/slot C output relay extension module
Slot B 5/12 V digital encoder interface module
Slot B analog encoder interface module
Slot B resolver encoder interface module
[Us] rated supply voltage 380...480 V - 15...10 %
[Us] rated supply voltage 380...480 V
Relative symmetric mains voltage tolerance 10 %
Relative symmetric network frequency tolerance 5 %
nominal output current 302.0 A
Motor power kW 160.0 kW normal duty
132.0 kW heavy duty
EMC filter Integrated
With EMC plate option
IP degree of protection IP21
Degree of protection UL type 1

Complementary

Characteristic Value(s)
Electrical connection Line side screw terminal 2 x 95...3 x 120 mm² 2 x AWG 3/0...2 x 300 kcmil
DC bus screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Local signalling Local diagnostic: 3 LEDs (mono/dual colour)
5 LEDs (dual colour)
2 LEDs (dual colour)
1 LED (red)
Isolation Between power and control terminals
Discrete input number 10
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
S, U or customized
Motor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
Switching frequency 1...8 kHz adjustable
2.5...8 kHz with derating factor
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 284.0 A 380 V normal duty)
237.0 A 380 V heavy duty)
262.0 A 480 V normal duty)
213.0 A 480 V heavy duty)
Maximum Input Current per Phase 284.0 A
Maximum output voltage 480.0 V
Apparent power 201.3 kVA 380...480 V normal duty)
161.4 kVA 380...480 V heavy duty)
Maximum transient current 362 A 60 s normal duty)
375 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 250.0 A
Base load current at low overload 302.0 A
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 12.6 in (320 mm)
Height 47.4 in (1205 mm)
Depth 15.5 in (393 mm)
Product Weight 229.3 lb(US) (104 kg)
Characteristic Value(s)
Electrical connection Line side screw terminal 2 x 95...3 x 120 mm² 2 x AWG 3/0...2 x 300 kcmil
DC bus screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16
Transmission Rate 10/100 Mbit/s Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Data format 8 bits, configurable odd, even or no parity Modbus serial
Type of polarization No impedance Modbus serial
Number of addresses 1…247 Modbus serial
Local signalling Local diagnostic: 3 LEDs (mono/dual colour)
5 LEDs (dual colour)
2 LEDs (dual colour)
1 LED (red)
Isolation Between power and control terminals
Discrete input number 10
Relay output type Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
Physical interface Ethernet
2-wire RS 485
Connector Type 2 RJ45
1 RJ45
Method of access Slave Modbus TCP
Transmission Rate 10, 100 Mbits
4.8 kbps
9600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency 599 Hz
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
S, U or customized
Motor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
Switching frequency 1...8 kHz adjustable
2.5...8 kHz with derating factor
Nominal switching frequency 2.5 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 284.0 A 380 V normal duty)
237.0 A 380 V heavy duty)
262.0 A 480 V normal duty)
213.0 A 480 V heavy duty)
Maximum Input Current per Phase 284.0 A
Maximum output voltage 480.0 V
Apparent power 201.3 kVA 380...480 V normal duty)
161.4 kVA 380...480 V heavy duty)
Maximum transient current 362 A 60 s normal duty)
375 A 60 s heavy duty)
Network Frequency 50-60 Hz
Prospective line Isc 50 kA
Base load current at high overload 250.0 A
Base load current at low overload 302.0 A
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set 1
Width 12.6 in (320 mm)
Height 47.4 in (1205 mm)
Depth 15.5 in (393 mm)
Product Weight 229.3 lb(US) (104 kg)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator