1SDA070969R1 ABB - E2.2S 1250 Ekip Hi-Touch LSIG 3p F HR

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
93951f71-79f6-4cd1-80e4-c7909f9baa54 Italy
Simplified SCIP:
77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany
bffca4b8-cc43-4760-9490-599d85598d59 Poland
e66feb15-45a7-402a-885b-567ad390a6e3 Poland
16400ca4-5e80-4420-982b-8573796a6059 Hungary
d01d409d-835b-4eba-81f3-1a206a2f1b24 Belgium
59f22650-15c6-4cf3-81e8-936fb8c114dc Spain
2392a3fb-3f44-46f4-9dbe-35b3f18fd0a3 Czech Republic
d856b782-40d9-4d5f-9eaf-6ac5d42fe19e Poland
283339fe-92aa-4860-af51-cda42672e306 Norway
6fd0a2c2-40a6-4c1b-8891-da5cc7f79bf9 Hungary
f434cbad-8c1f-492e-9765-c8f8167927d4 Estonia
86d5c231-42f5-446b-a34e-43304d107673 Denmark
53abf30e-bf07-4085-8cce-5c8cd62100af Germany
dbf528bf-9554-4f30-b26a-02c4a26f0b00 Germany
272adc79-6785-401e-80b5-e2b2e3cbcbcd Germany
0fc4f35f-d13c-4c03-8f09-abc9a3437745 Germany
6ac32107-d851-47e7-9702-8bef3e0e530d Sweden
b7da3638-55c2-402e-8420-ae7abe843e93 Belgium
9396dbfd-071e-4f90-b7df-2f924996de4f Netherlands
80792894-4f83-4c20-9dab-294c74097336 France
0e3108de-20ee-4ddb-9c12-180961e99ce3 Greece
c028809b-13c3-4445-9c69-71828cb7c52f Finland
a1694668-4cc1-476e-99ef-3e2f5b40eebb Bulgaria
5e88e40e-524e-48d0-9f09-e7cf486a62a1 Croatia
c50f5f90-efff-420c-bb42-c569d4703136 France
3d9c4630-bd46-4103-bfa8-16d8631b5e9f Portugal
dcc2e542-6ea2-40ce-a663-fd493265c721 Sweden
77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany
bffca4b8-cc43-4760-9490-599d85598d59 Poland
e66feb15-45a7-402a-885b-567ad390a6e3 Poland
16400ca4-5e80-4420-982b-8573796a6059 Hungary
d01d409d-835b-4eba-81f3-1a206a2f1b24 Belgium
59f22650-15c6-4cf3-81e8-936fb8c114dc Spain
2392a3fb-3f44-46f4-9dbe-35b3f18fd0a3 Czech Republic
d856b782-40d9-4d5f-9eaf-6ac5d42fe19e Poland
283339fe-92aa-4860-af51-cda42672e306 Norway
6fd0a2c2-40a6-4c1b-8891-da5cc7f79bf9 Hungary

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z2SREHBK200A000000XX
EAN:
8015644748197
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
276 mm
Product Net Height:
371 mm
Product Net Depth / Length:
270 mm
Product Net Weight:
41 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
515 mm
Package Level 1 Gross Weight:
46 kg
Package Level 1 EAN:
8015644748197

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
83 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M12
Release:
Ekip Hi-Touch LSIG
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Rear flat Horizontal
Terminal Type:
Bolt
Tightening Torque:
70 N·m

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
93951f71-79f6-4cd1-80e4-c7909f9baa54 Italy
Simplified SCIP:
77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany
bffca4b8-cc43-4760-9490-599d85598d59 Poland
e66feb15-45a7-402a-885b-567ad390a6e3 Poland
16400ca4-5e80-4420-982b-8573796a6059 Hungary
d01d409d-835b-4eba-81f3-1a206a2f1b24 Belgium
59f22650-15c6-4cf3-81e8-936fb8c114dc Spain
2392a3fb-3f44-46f4-9dbe-35b3f18fd0a3 Czech Republic
d856b782-40d9-4d5f-9eaf-6ac5d42fe19e Poland
283339fe-92aa-4860-af51-cda42672e306 Norway
6fd0a2c2-40a6-4c1b-8891-da5cc7f79bf9 Hungary
f434cbad-8c1f-492e-9765-c8f8167927d4 Estonia
86d5c231-42f5-446b-a34e-43304d107673 Denmark
53abf30e-bf07-4085-8cce-5c8cd62100af Germany
dbf528bf-9554-4f30-b26a-02c4a26f0b00 Germany
272adc79-6785-401e-80b5-e2b2e3cbcbcd Germany
0fc4f35f-d13c-4c03-8f09-abc9a3437745 Germany
6ac32107-d851-47e7-9702-8bef3e0e530d Sweden
b7da3638-55c2-402e-8420-ae7abe843e93 Belgium
9396dbfd-071e-4f90-b7df-2f924996de4f Netherlands
80792894-4f83-4c20-9dab-294c74097336 France
0e3108de-20ee-4ddb-9c12-180961e99ce3 Greece
c028809b-13c3-4445-9c69-71828cb7c52f Finland
a1694668-4cc1-476e-99ef-3e2f5b40eebb Bulgaria
5e88e40e-524e-48d0-9f09-e7cf486a62a1 Croatia
c50f5f90-efff-420c-bb42-c569d4703136 France
3d9c4630-bd46-4103-bfa8-16d8631b5e9f Portugal
dcc2e542-6ea2-40ce-a663-fd493265c721 Sweden
77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany
bffca4b8-cc43-4760-9490-599d85598d59 Poland
e66feb15-45a7-402a-885b-567ad390a6e3 Poland
16400ca4-5e80-4420-982b-8573796a6059 Hungary
d01d409d-835b-4eba-81f3-1a206a2f1b24 Belgium
59f22650-15c6-4cf3-81e8-936fb8c114dc Spain
2392a3fb-3f44-46f4-9dbe-35b3f18fd0a3 Czech Republic
d856b782-40d9-4d5f-9eaf-6ac5d42fe19e Poland
283339fe-92aa-4860-af51-cda42672e306 Norway
6fd0a2c2-40a6-4c1b-8891-da5cc7f79bf9 Hungary

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z2SREHBK200A000000XX
EAN:
8015644748197
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
276 mm
Product Net Height:
371 mm
Product Net Depth / Length:
270 mm
Product Net Weight:
41 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
515 mm
Package Level 1 Gross Weight:
46 kg
Package Level 1 EAN:
8015644748197

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
83 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M12
Release:
Ekip Hi-Touch LSIG
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Rear flat Horizontal
Terminal Type:
Bolt
Tightening Torque:
70 N·m

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator