1SDA068345R1 ABB - XT4H 250 TMA 250-2500 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.30 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
62f9b351-ae79-4e9f-bcc2-3128e3e2c068 Italy
Simplified SCIP:
a666ddee-2f0c-4cc9-b780-45990b58daf1 France
5fc8293e-1254-426f-9c08-917a0fefa1c9 Hungary
d8363695-6bd4-4b93-8d7f-704aba26987e Spain
55a55b89-0a86-4b66-b799-b2bebeefd9a5 Belgium
2cdfac74-28b9-410f-b447-ebe0790a78bb Portugal
89f82776-1052-4d91-b549-432bed4af6f6 Sweden
c1ad9aab-0fca-489c-9bd8-cc6858c73e3a Denmark
2194f03c-206b-421b-b48b-255f38b3c7f9 Germany
439d606c-53fe-4d76-a049-2d99d573e5d5 Croatia
00d22dac-8573-4a2d-977e-f5bade8ed752 Germany
39696282-b1ab-4610-9a36-89952adc2c23 Germany
e00cab3c-82ee-4441-b67b-600e947eddce Czech Republic
5aa5b7db-121e-4b67-b890-f3b0463595ef Finland
5ef4a016-2cc4-40cb-a478-ac96c72429fc Germany
8ffbe887-725b-4704-99a2-f93c232b6f95 Poland
694e7183-4ac1-4a13-a8b3-ee80f93c0f8f Poland
24247938-7415-4855-ba4f-566e4fddbd73 Bulgaria
45c0fb37-15e5-4588-95ae-711e85044975 Sweden
265478ed-ed1e-4409-9c0c-8b81cbff4d50 Netherlands
efdc7c30-8fe1-4ecf-b929-3fe26ce7f5e1 Norway
51a1b38e-2881-4b85-85fc-e4df0031051c France
d209594f-884f-433d-b226-c700b5339f11 Greece
9ab14d06-cec2-471c-98db-a78af23d27e0 Germany
6f10939e-fcef-4c3e-9de4-3554146772c9 Estonia
db432cbc-16cf-4ee1-9d18-6a2cf39da8ec Belgium
17cad91e-24dc-4e76-8a9f-d98d82c8e84e Poland
df9f87c4-e9c4-44a7-9ba9-df705883ce17 Hungary
a666ddee-2f0c-4cc9-b780-45990b58daf1 France
5fc8293e-1254-426f-9c08-917a0fefa1c9 Hungary
d8363695-6bd4-4b93-8d7f-704aba26987e Spain
55a55b89-0a86-4b66-b799-b2bebeefd9a5 Belgium
2cdfac74-28b9-410f-b447-ebe0790a78bb Portugal
89f82776-1052-4d91-b549-432bed4af6f6 Sweden
c1ad9aab-0fca-489c-9bd8-cc6858c73e3a Denmark
2194f03c-206b-421b-b48b-255f38b3c7f9 Germany
439d606c-53fe-4d76-a049-2d99d573e5d5 Croatia
00d22dac-8573-4a2d-977e-f5bade8ed752 Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT4HE3250BFF000XXX
E-Number (Finland):
3638098
E-Number (Norway):
4379904
EAN:
8015644022518
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
160 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
2.253 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
151 mm
Package Level 1 Height:
214 mm
Package Level 1 Depth / Length:
171 mm
Package Level 1 Gross Weight:
2.386 kg
Package Level 1 EAN:
8015644022518

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..200 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 16.44 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1250…2500 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
750 V DC
690 V AC
750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMA
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
H
Standards:
IEC60947-2
Sub-type:
XT4
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.30 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
62f9b351-ae79-4e9f-bcc2-3128e3e2c068 Italy
Simplified SCIP:
a666ddee-2f0c-4cc9-b780-45990b58daf1 France
5fc8293e-1254-426f-9c08-917a0fefa1c9 Hungary
d8363695-6bd4-4b93-8d7f-704aba26987e Spain
55a55b89-0a86-4b66-b799-b2bebeefd9a5 Belgium
2cdfac74-28b9-410f-b447-ebe0790a78bb Portugal
89f82776-1052-4d91-b549-432bed4af6f6 Sweden
c1ad9aab-0fca-489c-9bd8-cc6858c73e3a Denmark
2194f03c-206b-421b-b48b-255f38b3c7f9 Germany
439d606c-53fe-4d76-a049-2d99d573e5d5 Croatia
00d22dac-8573-4a2d-977e-f5bade8ed752 Germany
39696282-b1ab-4610-9a36-89952adc2c23 Germany
e00cab3c-82ee-4441-b67b-600e947eddce Czech Republic
5aa5b7db-121e-4b67-b890-f3b0463595ef Finland
5ef4a016-2cc4-40cb-a478-ac96c72429fc Germany
8ffbe887-725b-4704-99a2-f93c232b6f95 Poland
694e7183-4ac1-4a13-a8b3-ee80f93c0f8f Poland
24247938-7415-4855-ba4f-566e4fddbd73 Bulgaria
45c0fb37-15e5-4588-95ae-711e85044975 Sweden
265478ed-ed1e-4409-9c0c-8b81cbff4d50 Netherlands
efdc7c30-8fe1-4ecf-b929-3fe26ce7f5e1 Norway
51a1b38e-2881-4b85-85fc-e4df0031051c France
d209594f-884f-433d-b226-c700b5339f11 Greece
9ab14d06-cec2-471c-98db-a78af23d27e0 Germany
6f10939e-fcef-4c3e-9de4-3554146772c9 Estonia
db432cbc-16cf-4ee1-9d18-6a2cf39da8ec Belgium
17cad91e-24dc-4e76-8a9f-d98d82c8e84e Poland
df9f87c4-e9c4-44a7-9ba9-df705883ce17 Hungary
a666ddee-2f0c-4cc9-b780-45990b58daf1 France
5fc8293e-1254-426f-9c08-917a0fefa1c9 Hungary
d8363695-6bd4-4b93-8d7f-704aba26987e Spain
55a55b89-0a86-4b66-b799-b2bebeefd9a5 Belgium
2cdfac74-28b9-410f-b447-ebe0790a78bb Portugal
89f82776-1052-4d91-b549-432bed4af6f6 Sweden
c1ad9aab-0fca-489c-9bd8-cc6858c73e3a Denmark
2194f03c-206b-421b-b48b-255f38b3c7f9 Germany
439d606c-53fe-4d76-a049-2d99d573e5d5 Croatia
00d22dac-8573-4a2d-977e-f5bade8ed752 Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT4HE3250BFF000XXX
E-Number (Finland):
3638098
E-Number (Norway):
4379904
EAN:
8015644022518
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
160 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
2.253 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
151 mm
Package Level 1 Height:
214 mm
Package Level 1 Depth / Length:
171 mm
Package Level 1 Gross Weight:
2.386 kg
Package Level 1 EAN:
8015644022518

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..200 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 16.44 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1250…2500 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
750 V DC
690 V AC
750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 45 kA
(690 V AC) 15 kA
(250 V DC) 2 Poles in Series 70 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMA
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
H
Standards:
IEC60947-2
Sub-type:
XT4
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator