1SDA068057R1 ABB - XT3N 250 TMD 160-1600 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
9bbfba75-9598-428d-b05c-f0866bf2751d Italy
Simplified SCIP:
186dcd54-25fa-4101-9c9d-b698b1d9acbd Germany
0f0b6c02-b429-4c5b-926f-cb98f2d67a2a Netherlands
98303b6e-e09e-4d19-b13c-ca9a183fa838 Germany
9c07c0e2-1148-4ec8-86fe-83805de4787c Sweden
d6110866-5eb1-4998-846a-f3abb00c6ac8 Germany
b6b5a8ba-d149-47be-86db-2706e8b5d07a Croatia
9c8684f1-75a6-411d-b40c-b2c1eb903a29 Poland
66e732e6-a80f-46ea-9100-dc9681f76b58 Norway
a2af9d3f-d2ac-40c2-ac89-95e627804dab Finland
82e8de99-3818-41fd-9db5-91ebce08b7f2 Netherlands
3a54d027-860b-411a-ab7e-7794a03b2661 Germany
c29148ed-c752-4943-957b-48e521c158ee Bulgaria
6c0ae89b-503b-40c5-b10c-ff76a49d3008 Sweden
d6c64ba9-85dc-481a-85b8-f90725c33c5d Denmark
e57dfc82-4dc2-4877-8dff-06df839ec912 Poland
837fc8cc-9c01-4d53-9da3-a45547db61cc France
6c291123-4d2c-4a87-b5eb-6628e649ce91 Netherlands
dcf6a8aa-4991-4f94-a572-0ced9306f46f Czech Republic
cbc03a45-e6a8-48ca-8bc6-79ff97ca0363 Poland
b22f5b77-4e46-4d88-84e2-f6591e411317 Netherlands
78537439-cebf-4238-a8f9-c2074c24574d Estonia
c4b3c616-343d-4c0c-b00b-dfd8fdc44373 Greece
f05da2e3-db7d-41e9-880a-f2c26a984e4d Portugal
c5a1d7c1-1ab9-446e-adf0-e252be4f7576 Germany
083ae48c-ec3e-45db-b57c-63d74c83cfbe France
9933c2d8-203d-4642-9ef1-e02ec99f9ecd Netherlands
7fe72321-80b3-4336-9e2f-4e3501fd7699 Spain
186dcd54-25fa-4101-9c9d-b698b1d9acbd Germany
0f0b6c02-b429-4c5b-926f-cb98f2d67a2a Netherlands
98303b6e-e09e-4d19-b13c-ca9a183fa838 Germany
9c07c0e2-1148-4ec8-86fe-83805de4787c Sweden
d6110866-5eb1-4998-846a-f3abb00c6ac8 Germany
b6b5a8ba-d149-47be-86db-2706e8b5d07a Croatia
9c8684f1-75a6-411d-b40c-b2c1eb903a29 Poland
66e732e6-a80f-46ea-9100-dc9681f76b58 Norway
a2af9d3f-d2ac-40c2-ac89-95e627804dab Finland
82e8de99-3818-41fd-9db5-91ebce08b7f2 Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NE3160AFF000XXX
E-Number (Norway):
4309661
E-Number (Sweden):
3182433
EAN:
8015644019280
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.7 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
1.702 kg
Package Level 1 EAN:
8015644019280

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7.9 W
Rated Current (In):
160 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1600 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
112...160 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price2,778.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
2,778.00 kr
0.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
9bbfba75-9598-428d-b05c-f0866bf2751d Italy
Simplified SCIP:
186dcd54-25fa-4101-9c9d-b698b1d9acbd Germany
0f0b6c02-b429-4c5b-926f-cb98f2d67a2a Netherlands
98303b6e-e09e-4d19-b13c-ca9a183fa838 Germany
9c07c0e2-1148-4ec8-86fe-83805de4787c Sweden
d6110866-5eb1-4998-846a-f3abb00c6ac8 Germany
b6b5a8ba-d149-47be-86db-2706e8b5d07a Croatia
9c8684f1-75a6-411d-b40c-b2c1eb903a29 Poland
66e732e6-a80f-46ea-9100-dc9681f76b58 Norway
a2af9d3f-d2ac-40c2-ac89-95e627804dab Finland
82e8de99-3818-41fd-9db5-91ebce08b7f2 Netherlands
3a54d027-860b-411a-ab7e-7794a03b2661 Germany
c29148ed-c752-4943-957b-48e521c158ee Bulgaria
6c0ae89b-503b-40c5-b10c-ff76a49d3008 Sweden
d6c64ba9-85dc-481a-85b8-f90725c33c5d Denmark
e57dfc82-4dc2-4877-8dff-06df839ec912 Poland
837fc8cc-9c01-4d53-9da3-a45547db61cc France
6c291123-4d2c-4a87-b5eb-6628e649ce91 Netherlands
dcf6a8aa-4991-4f94-a572-0ced9306f46f Czech Republic
cbc03a45-e6a8-48ca-8bc6-79ff97ca0363 Poland
b22f5b77-4e46-4d88-84e2-f6591e411317 Netherlands
78537439-cebf-4238-a8f9-c2074c24574d Estonia
c4b3c616-343d-4c0c-b00b-dfd8fdc44373 Greece
f05da2e3-db7d-41e9-880a-f2c26a984e4d Portugal
c5a1d7c1-1ab9-446e-adf0-e252be4f7576 Germany
083ae48c-ec3e-45db-b57c-63d74c83cfbe France
9933c2d8-203d-4642-9ef1-e02ec99f9ecd Netherlands
7fe72321-80b3-4336-9e2f-4e3501fd7699 Spain
186dcd54-25fa-4101-9c9d-b698b1d9acbd Germany
0f0b6c02-b429-4c5b-926f-cb98f2d67a2a Netherlands
98303b6e-e09e-4d19-b13c-ca9a183fa838 Germany
9c07c0e2-1148-4ec8-86fe-83805de4787c Sweden
d6110866-5eb1-4998-846a-f3abb00c6ac8 Germany
b6b5a8ba-d149-47be-86db-2706e8b5d07a Croatia
9c8684f1-75a6-411d-b40c-b2c1eb903a29 Poland
66e732e6-a80f-46ea-9100-dc9681f76b58 Norway
a2af9d3f-d2ac-40c2-ac89-95e627804dab Finland
82e8de99-3818-41fd-9db5-91ebce08b7f2 Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NE3160AFF000XXX
E-Number (Norway):
4309661
E-Number (Sweden):
3182433
EAN:
8015644019280
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
105 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.7 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
1.702 kg
Package Level 1 EAN:
8015644019280

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7.9 W
Rated Current (In):
160 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1600 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
112...160 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator