1SDA067579R1 ABB XT2S 160 TMA 100-1000 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
3ab5640d-37fb-4cae-81f8-cfec9c602b02 Italy
Simplified SCIP:
2d089f31-cb88-4915-8170-59efad6bb39d Germany
1682bfc3-bfff-4b4b-b66a-f09c758ac429 Netherlands
72d025f7-fcb6-4240-9b25-35ee1675e21d Bulgaria
ce33effe-16fc-4560-8618-61463d052835 Sweden
e6b22c86-4c0f-49bf-b640-50bed22d6edd Poland
2991b0f8-1acd-4a14-897e-6916f60b24fd France
9db1cdbe-c313-47ba-a0b2-7ceef06aa1f1 Poland
ec8b4785-15d3-444c-85c8-3680b3822b0c Norway
43ee3bd3-b26d-4a36-ab66-efb14b09a97d Finland
08fe280f-9a1b-4882-bcc6-478ef91fea5c Netherlands
791cd437-8385-410e-a7b9-97f8e56bea72 Germany
5d2d5d65-fa86-4380-b01b-4bb882cbe325 Netherlands
d385cc2f-5f88-42bf-a647-9ddb3d4530ef Netherlands
f9807cb5-3cd9-41a0-9a89-948a9ffc334c Poland
bf1635c3-de67-446a-8dd4-aaa10a6e2f7f Sweden
c072697a-9563-4ec0-a80d-00b1c942044f Germany
08e7fa02-2acd-4bf3-93a7-cc9f03ad363c Germany
ed427cf6-fcf7-4c40-a60b-d21a72d4c839 France
46d51828-4bb9-4245-9535-1c58e21954ba Netherlands
293861c1-a0df-49d4-b2f0-05d2adf8bd36 Spain
5116c9d0-6ced-48b9-a24c-7c804e156a57 Estonia
c215591f-8132-4d7e-963d-b82ca6d8fa82 Greece
c37f9121-d2ca-4d88-b85a-792a5e81795e Portugal
fe667a36-bf30-4170-a9a6-2b48fa5c0106 Denmark
2784b2c1-3172-4b77-95d3-e16b44fec3b0 Germany
0d8519f1-4f4a-431b-87bf-9963601202cd Croatia
80e6f324-02d5-4391-b66c-67b0ba5a86f9 Czech Republic
2d089f31-cb88-4915-8170-59efad6bb39d Germany
1682bfc3-bfff-4b4b-b66a-f09c758ac429 Netherlands
72d025f7-fcb6-4240-9b25-35ee1675e21d Bulgaria
ce33effe-16fc-4560-8618-61463d052835 Sweden
e6b22c86-4c0f-49bf-b640-50bed22d6edd Poland
2991b0f8-1acd-4a14-897e-6916f60b24fd France
9db1cdbe-c313-47ba-a0b2-7ceef06aa1f1 Poland
ec8b4785-15d3-444c-85c8-3680b3822b0c Norway
43ee3bd3-b26d-4a36-ab66-efb14b09a97d Finland
08fe280f-9a1b-4882-bcc6-478ef91fea5c Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE4100BFF000XXX
E-Number (Finland):
3640599
E-Number (Norway):
4379595
EAN:
8015644014759
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
120 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.45 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
131 mm
Package Level 1 Height:
212 mm
Package Level 1 Depth / Length:
147 mm
Package Level 1 Gross Weight:
1.55 kg
Package Level 1 EAN:
8015644014759

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 8.08 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
500…1000 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMA
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.70 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
3ab5640d-37fb-4cae-81f8-cfec9c602b02 Italy
Simplified SCIP:
2d089f31-cb88-4915-8170-59efad6bb39d Germany
1682bfc3-bfff-4b4b-b66a-f09c758ac429 Netherlands
72d025f7-fcb6-4240-9b25-35ee1675e21d Bulgaria
ce33effe-16fc-4560-8618-61463d052835 Sweden
e6b22c86-4c0f-49bf-b640-50bed22d6edd Poland
2991b0f8-1acd-4a14-897e-6916f60b24fd France
9db1cdbe-c313-47ba-a0b2-7ceef06aa1f1 Poland
ec8b4785-15d3-444c-85c8-3680b3822b0c Norway
43ee3bd3-b26d-4a36-ab66-efb14b09a97d Finland
08fe280f-9a1b-4882-bcc6-478ef91fea5c Netherlands
791cd437-8385-410e-a7b9-97f8e56bea72 Germany
5d2d5d65-fa86-4380-b01b-4bb882cbe325 Netherlands
d385cc2f-5f88-42bf-a647-9ddb3d4530ef Netherlands
f9807cb5-3cd9-41a0-9a89-948a9ffc334c Poland
bf1635c3-de67-446a-8dd4-aaa10a6e2f7f Sweden
c072697a-9563-4ec0-a80d-00b1c942044f Germany
08e7fa02-2acd-4bf3-93a7-cc9f03ad363c Germany
ed427cf6-fcf7-4c40-a60b-d21a72d4c839 France
46d51828-4bb9-4245-9535-1c58e21954ba Netherlands
293861c1-a0df-49d4-b2f0-05d2adf8bd36 Spain
5116c9d0-6ced-48b9-a24c-7c804e156a57 Estonia
c215591f-8132-4d7e-963d-b82ca6d8fa82 Greece
c37f9121-d2ca-4d88-b85a-792a5e81795e Portugal
fe667a36-bf30-4170-a9a6-2b48fa5c0106 Denmark
2784b2c1-3172-4b77-95d3-e16b44fec3b0 Germany
0d8519f1-4f4a-431b-87bf-9963601202cd Croatia
80e6f324-02d5-4391-b66c-67b0ba5a86f9 Czech Republic
2d089f31-cb88-4915-8170-59efad6bb39d Germany
1682bfc3-bfff-4b4b-b66a-f09c758ac429 Netherlands
72d025f7-fcb6-4240-9b25-35ee1675e21d Bulgaria
ce33effe-16fc-4560-8618-61463d052835 Sweden
e6b22c86-4c0f-49bf-b640-50bed22d6edd Poland
2991b0f8-1acd-4a14-897e-6916f60b24fd France
9db1cdbe-c313-47ba-a0b2-7ceef06aa1f1 Poland
ec8b4785-15d3-444c-85c8-3680b3822b0c Norway
43ee3bd3-b26d-4a36-ab66-efb14b09a97d Finland
08fe280f-9a1b-4882-bcc6-478ef91fea5c Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT2SE4100BFF000XXX
E-Number (Finland):
3640599
E-Number (Norway):
4379595
EAN:
8015644014759
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
120 mm
Product Net Height:
130 mm
Product Net Depth / Length:
82.5 mm
Product Net Weight:
1.45 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
131 mm
Package Level 1 Height:
212 mm
Package Level 1 Depth / Length:
147 mm
Package Level 1 Gross Weight:
1.55 kg
Package Level 1 EAN:
8015644014759

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 32.5..100 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 8.08 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
500…1000 A
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 36 kA
(525 V AC) 25 kA
(690 V AC) 12 kA
(250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMA
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
S
Standards:
IEC60947-2
Sub-type:
XT2
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator