1SDA067397R1 ABB - XT1C 160 TMD 100-1000 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy
Simplified SCIP:
0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany
690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands
1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands
faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany
3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark
adf816cc-8afa-408f-b37f-84d38645b9ce Germany
f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia
a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic
b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands
678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands
2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia
769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece
c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal
0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria
3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden
3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland
25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France
dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden
3b414454-d89f-4090-bb59-470a3c7330ea Germany
59695450-664d-4372-9510-6f5c4ac5ad03 Germany
35ec2353-58cd-472a-b909-85aa064a6204 Spain
95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands
5ec14cea-f544-4faa-ab16-fd3819a27732 Poland
ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland
37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland
3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway
b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France
0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany
690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands
1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands
faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany
3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark
adf816cc-8afa-408f-b37f-84d38645b9ce Germany
f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia
a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic
b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands
678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1CE3100AFF000XXX
E-Number (Finland):
3638777
E-Number (Norway):
4309617
EAN:
8015644012915
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.136 kg
Package Level 1 EAN:
8015644012915

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
C
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price1,351.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
1,351.00 kr
0.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy
Simplified SCIP:
0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany
690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands
1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands
faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany
3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark
adf816cc-8afa-408f-b37f-84d38645b9ce Germany
f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia
a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic
b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands
678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands
2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia
769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece
c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal
0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria
3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden
3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland
25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France
dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden
3b414454-d89f-4090-bb59-470a3c7330ea Germany
59695450-664d-4372-9510-6f5c4ac5ad03 Germany
35ec2353-58cd-472a-b909-85aa064a6204 Spain
95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands
5ec14cea-f544-4faa-ab16-fd3819a27732 Poland
ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland
37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland
3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway
b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France
0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany
690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands
1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands
faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany
3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark
adf816cc-8afa-408f-b37f-84d38645b9ce Germany
f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia
a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic
b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands
678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1CE3100AFF000XXX
E-Number (Finland):
3638777
E-Number (Norway):
4309617
EAN:
8015644012915
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.136 kg
Package Level 1 EAN:
8015644012915

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
C
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator