1SDA066819R1 ABB XT1B 160 TMD 125-1250 4p F F InN50%

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
181894a4-69ef-4895-a66a-25dd0eef5d9d Italy
Simplified SCIP:
e427db7b-10bf-4025-b7ac-81c12f5ea1c7 Germany
4de8c36f-2cbb-4e8a-a8b4-2f475f189501 Netherlands
40136458-e14e-476e-8179-7ea32264365e Poland
6613de96-0b00-4191-b40f-0f4bcc795b24 Norway
6caa81af-d20d-499e-80ef-330da21b0df5 Finland
f335879b-9cd2-4125-9222-7e706babd337 Netherlands
88e3ca0a-5644-4253-9d8f-8bd9d78bfe8b Germany
5d3cd608-24bc-42fc-900c-aed277a4834a Denmark
e62f2b2a-4586-4e3b-b8c1-2a6912d19409 Germany
767991c0-f474-410b-a9b2-2ce8ee3290af Croatia
6e3ccc1e-5d7f-4ff2-a751-d17da170a7c7 Czech Republic
ad3517c0-061e-4ff0-a6b2-237e948f1276 Poland
14cb9065-5ca5-4d49-b88b-1882425ce23e Netherlands
7cb4acd2-9714-4014-abee-36ab38d8da7b Netherlands
ce0c3d9a-ab70-4dc4-9dec-6e585950628c Estonia
679052fd-3ccd-4ff9-9a43-70bee57b22ee Greece
98a310da-f88a-4cb6-8d20-142045dc2217 Portugal
ee52d4f7-7a3b-46a5-9e3b-a4a407848a77 Bulgaria
8842217a-946c-48ee-9a1b-2e3ee9b99d2e Sweden
130ff520-5aa1-496a-8479-8755a05447c7 Poland
78ef2262-3bdc-41f4-b8b7-f303bb1aed8f France
e3117c04-36cf-4309-b0aa-ad330acf7bd6 Sweden
cda6b271-229e-405c-bb4f-9fa49d80f0fa Germany
3f7bb12f-3f0c-4fa1-ae78-06054dd9a486 Germany
15ccfe03-d457-4da9-9ec1-9ff6c5d4d960 France
d631c483-9c97-4b94-9277-790736b5e721 Netherlands
b1f65d4f-fb08-4e59-9a80-3339b41e8b98 Spain
e427db7b-10bf-4025-b7ac-81c12f5ea1c7 Germany
4de8c36f-2cbb-4e8a-a8b4-2f475f189501 Netherlands
40136458-e14e-476e-8179-7ea32264365e Poland
6613de96-0b00-4191-b40f-0f4bcc795b24 Norway
6caa81af-d20d-499e-80ef-330da21b0df5 Finland
f335879b-9cd2-4125-9222-7e706babd337 Netherlands
88e3ca0a-5644-4253-9d8f-8bd9d78bfe8b Germany
5d3cd608-24bc-42fc-900c-aed277a4834a Denmark
e62f2b2a-4586-4e3b-b8c1-2a6912d19409 Germany
767991c0-f474-410b-a9b2-2ce8ee3290af Croatia

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BEN125AFF000XXX
E-Number (Finland):
3640501
EAN:
8015644007263
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.447 kg
Package Level 1 EAN:
8015644007263

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 10.7 W
Rated Current (In):
125 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1250 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
87.5...125 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
181894a4-69ef-4895-a66a-25dd0eef5d9d Italy
Simplified SCIP:
e427db7b-10bf-4025-b7ac-81c12f5ea1c7 Germany
4de8c36f-2cbb-4e8a-a8b4-2f475f189501 Netherlands
40136458-e14e-476e-8179-7ea32264365e Poland
6613de96-0b00-4191-b40f-0f4bcc795b24 Norway
6caa81af-d20d-499e-80ef-330da21b0df5 Finland
f335879b-9cd2-4125-9222-7e706babd337 Netherlands
88e3ca0a-5644-4253-9d8f-8bd9d78bfe8b Germany
5d3cd608-24bc-42fc-900c-aed277a4834a Denmark
e62f2b2a-4586-4e3b-b8c1-2a6912d19409 Germany
767991c0-f474-410b-a9b2-2ce8ee3290af Croatia
6e3ccc1e-5d7f-4ff2-a751-d17da170a7c7 Czech Republic
ad3517c0-061e-4ff0-a6b2-237e948f1276 Poland
14cb9065-5ca5-4d49-b88b-1882425ce23e Netherlands
7cb4acd2-9714-4014-abee-36ab38d8da7b Netherlands
ce0c3d9a-ab70-4dc4-9dec-6e585950628c Estonia
679052fd-3ccd-4ff9-9a43-70bee57b22ee Greece
98a310da-f88a-4cb6-8d20-142045dc2217 Portugal
ee52d4f7-7a3b-46a5-9e3b-a4a407848a77 Bulgaria
8842217a-946c-48ee-9a1b-2e3ee9b99d2e Sweden
130ff520-5aa1-496a-8479-8755a05447c7 Poland
78ef2262-3bdc-41f4-b8b7-f303bb1aed8f France
e3117c04-36cf-4309-b0aa-ad330acf7bd6 Sweden
cda6b271-229e-405c-bb4f-9fa49d80f0fa Germany
3f7bb12f-3f0c-4fa1-ae78-06054dd9a486 Germany
15ccfe03-d457-4da9-9ec1-9ff6c5d4d960 France
d631c483-9c97-4b94-9277-790736b5e721 Netherlands
b1f65d4f-fb08-4e59-9a80-3339b41e8b98 Spain
e427db7b-10bf-4025-b7ac-81c12f5ea1c7 Germany
4de8c36f-2cbb-4e8a-a8b4-2f475f189501 Netherlands
40136458-e14e-476e-8179-7ea32264365e Poland
6613de96-0b00-4191-b40f-0f4bcc795b24 Norway
6caa81af-d20d-499e-80ef-330da21b0df5 Finland
f335879b-9cd2-4125-9222-7e706babd337 Netherlands
88e3ca0a-5644-4253-9d8f-8bd9d78bfe8b Germany
5d3cd608-24bc-42fc-900c-aed277a4834a Denmark
e62f2b2a-4586-4e3b-b8c1-2a6912d19409 Germany
767991c0-f474-410b-a9b2-2ce8ee3290af Croatia

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BEN125AFF000XXX
E-Number (Finland):
3640501
EAN:
8015644007263
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.447 kg
Package Level 1 EAN:
8015644007263

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 10.7 W
Rated Current (In):
125 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1250 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
87.5...125 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator