1SDA066818R1 ABB - XT1B 160 TMD 100-1000 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
688e96d7-2d1c-4e22-b59c-50ff06516bf8 Italy
Simplified SCIP:
b081d9e5-0266-467a-8f8f-906a85a12afa Germany
4be3f089-aca5-4fb8-8ca5-ca75d8b5d067 Sweden
27550f41-4161-4b3a-8225-f1e246ce2a09 Germany
6c03d9fa-a586-4041-bf40-cd77812ad7f8 Germany
90c62ad0-99e2-4cfb-a4b3-7a1d2b822175 Czech Republic
70f88417-6d1f-4419-b8ca-cd081ff4976a Poland
9f1ba41e-13c8-4949-8f02-c3e198ca3ccb Netherlands
7f066c37-7fb1-47df-b33d-5f27effe988d Netherlands
ba2a17d0-ebc2-40ef-8670-1145eb519351 Estonia
72d61050-bae5-4d72-b9f9-bd391a4a830e Greece
d9334c91-3248-4e66-9b4c-3919e09712e4 Portugal
dd27b78a-c66a-4eb0-b691-907a2e33f930 Norway
6bfbb959-ec01-495a-a4a0-08ac8e4e3667 Finland
8186f6da-48cd-49d8-a4ec-d7d71c32770c Netherlands
b3c31785-12c6-4630-83f1-b2d78d65bea1 Germany
9607cf14-ae26-4495-a29e-67cdeff195c1 Denmark
b7deb7c4-4af4-4932-8db3-8f1bd014dce3 Germany
d1429ebb-e55d-4293-a755-dff56a49be68 Croatia
6d10ed05-32eb-48f2-88a8-1b46926daf87 Poland
13935ad8-46e8-49d7-9e27-360bd0cbc6a4 France
d9a62902-39ce-4272-bc64-dbb65a1b0e6f Netherlands
c2927a9e-50d1-4415-82df-df6998b70511 Spain
fea510e3-600e-4a0a-9c52-8483df25f240 Netherlands
b55767a9-8b5d-4dce-b7f7-413e4c989aec Bulgaria
ed811c7e-4d71-472c-8176-6c42e3067f7e Sweden
4cd65b04-2f4a-4fe8-8d5a-cb5ddd0c309d Poland
458cef3b-a92d-4b27-894c-1c5125dd37d5 France
b081d9e5-0266-467a-8f8f-906a85a12afa Germany
4be3f089-aca5-4fb8-8ca5-ca75d8b5d067 Sweden
27550f41-4161-4b3a-8225-f1e246ce2a09 Germany
6c03d9fa-a586-4041-bf40-cd77812ad7f8 Germany
90c62ad0-99e2-4cfb-a4b3-7a1d2b822175 Czech Republic
70f88417-6d1f-4419-b8ca-cd081ff4976a Poland
9f1ba41e-13c8-4949-8f02-c3e198ca3ccb Netherlands
7f066c37-7fb1-47df-b33d-5f27effe988d Netherlands
ba2a17d0-ebc2-40ef-8670-1145eb519351 Estonia
72d61050-bae5-4d72-b9f9-bd391a4a830e Greece

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE4100AFF000XXX
E-Number (Finland):
3640500
E-Number (Norway):
4309708
EAN:
8015644007256
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.44 kg
Package Level 1 EAN:
8015644007256

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
688e96d7-2d1c-4e22-b59c-50ff06516bf8 Italy
Simplified SCIP:
b081d9e5-0266-467a-8f8f-906a85a12afa Germany
4be3f089-aca5-4fb8-8ca5-ca75d8b5d067 Sweden
27550f41-4161-4b3a-8225-f1e246ce2a09 Germany
6c03d9fa-a586-4041-bf40-cd77812ad7f8 Germany
90c62ad0-99e2-4cfb-a4b3-7a1d2b822175 Czech Republic
70f88417-6d1f-4419-b8ca-cd081ff4976a Poland
9f1ba41e-13c8-4949-8f02-c3e198ca3ccb Netherlands
7f066c37-7fb1-47df-b33d-5f27effe988d Netherlands
ba2a17d0-ebc2-40ef-8670-1145eb519351 Estonia
72d61050-bae5-4d72-b9f9-bd391a4a830e Greece
d9334c91-3248-4e66-9b4c-3919e09712e4 Portugal
dd27b78a-c66a-4eb0-b691-907a2e33f930 Norway
6bfbb959-ec01-495a-a4a0-08ac8e4e3667 Finland
8186f6da-48cd-49d8-a4ec-d7d71c32770c Netherlands
b3c31785-12c6-4630-83f1-b2d78d65bea1 Germany
9607cf14-ae26-4495-a29e-67cdeff195c1 Denmark
b7deb7c4-4af4-4932-8db3-8f1bd014dce3 Germany
d1429ebb-e55d-4293-a755-dff56a49be68 Croatia
6d10ed05-32eb-48f2-88a8-1b46926daf87 Poland
13935ad8-46e8-49d7-9e27-360bd0cbc6a4 France
d9a62902-39ce-4272-bc64-dbb65a1b0e6f Netherlands
c2927a9e-50d1-4415-82df-df6998b70511 Spain
fea510e3-600e-4a0a-9c52-8483df25f240 Netherlands
b55767a9-8b5d-4dce-b7f7-413e4c989aec Bulgaria
ed811c7e-4d71-472c-8176-6c42e3067f7e Sweden
4cd65b04-2f4a-4fe8-8d5a-cb5ddd0c309d Poland
458cef3b-a92d-4b27-894c-1c5125dd37d5 France
b081d9e5-0266-467a-8f8f-906a85a12afa Germany
4be3f089-aca5-4fb8-8ca5-ca75d8b5d067 Sweden
27550f41-4161-4b3a-8225-f1e246ce2a09 Germany
6c03d9fa-a586-4041-bf40-cd77812ad7f8 Germany
90c62ad0-99e2-4cfb-a4b3-7a1d2b822175 Czech Republic
70f88417-6d1f-4419-b8ca-cd081ff4976a Poland
9f1ba41e-13c8-4949-8f02-c3e198ca3ccb Netherlands
7f066c37-7fb1-47df-b33d-5f27effe988d Netherlands
ba2a17d0-ebc2-40ef-8670-1145eb519351 Estonia
72d61050-bae5-4d72-b9f9-bd391a4a830e Greece

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE4100AFF000XXX
E-Number (Finland):
3640500
E-Number (Norway):
4309708
EAN:
8015644007256
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.44 kg
Package Level 1 EAN:
8015644007256

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 7 W
Rated Current (In):
100 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1000 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
70...100 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator