1SDA066816R1 ABB - XT1B 160 TMD 63-630 4p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
7e73f8c2-9fcf-46fd-8ce8-8ff3065446c7 Italy
Simplified SCIP:
44cb4be4-a1b4-471c-80e4-5307577945cb Germany
2b4cd088-0d46-4c30-bb6a-fb441b7fb7fb Poland
b7062f07-5e00-42af-9950-e858adf3f3bd Norway
3f87f6c9-8b2b-4ba3-84e7-e4bf7c4dbc7c Finland
b0f1fc93-a34d-458d-8e5e-7e6c7fda2025 Netherlands
0994645c-6924-49ce-aa7d-e31f5e03f896 Germany
11a258b4-39ac-46b4-8a4c-aeed35ebf9da Denmark
7998dd24-22f6-40bf-90a9-f95105e027b1 Germany
1380dbaa-9f5b-4c5a-a7f2-568dc4c78999 Croatia
5ffe1b0a-3c9a-42c4-861e-3d907b4f9fa3 Czech Republic
6abaabeb-16c8-4cb6-aef2-7390cbe2b1da Poland
32be922d-f98f-47fe-9186-edcf13f4f64b Netherlands
54b32461-e46b-4996-bcf2-3f2b76dbdd71 Netherlands
43eb203d-6065-412f-b732-744eae5e5eb0 Estonia
c4908d83-b7ef-4b8d-8997-e74109d80de6 Greece
320d11f0-a17d-4e87-a794-375d391e75f4 Portugal
e6eb8d27-f481-4de3-a533-d3fe70af7f6a Bulgaria
34915fc1-7263-488f-b83f-da09bdd995be Sweden
a540bb0a-5c6d-479d-8984-36b5f089d8a7 Poland
c3e3417c-d555-4879-9f50-f327aba9cc45 France
cf23ebf3-cbe3-4128-a848-761e96a2adb6 Sweden
89e58f18-2822-40de-b715-47eeb3764a40 Germany
4f114a61-8884-4a65-a44a-0c453d2e1ada Germany
8e0863a3-ad22-4ce7-983c-ea3d4580aac7 France
61686ad8-6b0e-43f3-b96a-9777eabf3f98 Netherlands
1f1f32e9-0f0b-4294-84ff-23fee2cdc5ab Spain
72846ad8-efea-488f-9610-a0ce79670d85 Netherlands
44cb4be4-a1b4-471c-80e4-5307577945cb Germany
2b4cd088-0d46-4c30-bb6a-fb441b7fb7fb Poland
b7062f07-5e00-42af-9950-e858adf3f3bd Norway
3f87f6c9-8b2b-4ba3-84e7-e4bf7c4dbc7c Finland
b0f1fc93-a34d-458d-8e5e-7e6c7fda2025 Netherlands
0994645c-6924-49ce-aa7d-e31f5e03f896 Germany
11a258b4-39ac-46b4-8a4c-aeed35ebf9da Denmark
7998dd24-22f6-40bf-90a9-f95105e027b1 Germany
1380dbaa-9f5b-4c5a-a7f2-568dc4c78999 Croatia
5ffe1b0a-3c9a-42c4-861e-3d907b4f9fa3 Czech Republic

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE4063AFF000XXX
E-Number (Finland):
3638196
E-Number (Norway):
4309706
EAN:
8015644007232
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.43 kg
Package Level 1 EAN:
8015644007232

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
630 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
7e73f8c2-9fcf-46fd-8ce8-8ff3065446c7 Italy
Simplified SCIP:
44cb4be4-a1b4-471c-80e4-5307577945cb Germany
2b4cd088-0d46-4c30-bb6a-fb441b7fb7fb Poland
b7062f07-5e00-42af-9950-e858adf3f3bd Norway
3f87f6c9-8b2b-4ba3-84e7-e4bf7c4dbc7c Finland
b0f1fc93-a34d-458d-8e5e-7e6c7fda2025 Netherlands
0994645c-6924-49ce-aa7d-e31f5e03f896 Germany
11a258b4-39ac-46b4-8a4c-aeed35ebf9da Denmark
7998dd24-22f6-40bf-90a9-f95105e027b1 Germany
1380dbaa-9f5b-4c5a-a7f2-568dc4c78999 Croatia
5ffe1b0a-3c9a-42c4-861e-3d907b4f9fa3 Czech Republic
6abaabeb-16c8-4cb6-aef2-7390cbe2b1da Poland
32be922d-f98f-47fe-9186-edcf13f4f64b Netherlands
54b32461-e46b-4996-bcf2-3f2b76dbdd71 Netherlands
43eb203d-6065-412f-b732-744eae5e5eb0 Estonia
c4908d83-b7ef-4b8d-8997-e74109d80de6 Greece
320d11f0-a17d-4e87-a794-375d391e75f4 Portugal
e6eb8d27-f481-4de3-a533-d3fe70af7f6a Bulgaria
34915fc1-7263-488f-b83f-da09bdd995be Sweden
a540bb0a-5c6d-479d-8984-36b5f089d8a7 Poland
c3e3417c-d555-4879-9f50-f327aba9cc45 France
cf23ebf3-cbe3-4128-a848-761e96a2adb6 Sweden
89e58f18-2822-40de-b715-47eeb3764a40 Germany
4f114a61-8884-4a65-a44a-0c453d2e1ada Germany
8e0863a3-ad22-4ce7-983c-ea3d4580aac7 France
61686ad8-6b0e-43f3-b96a-9777eabf3f98 Netherlands
1f1f32e9-0f0b-4294-84ff-23fee2cdc5ab Spain
72846ad8-efea-488f-9610-a0ce79670d85 Netherlands
44cb4be4-a1b4-471c-80e4-5307577945cb Germany
2b4cd088-0d46-4c30-bb6a-fb441b7fb7fb Poland
b7062f07-5e00-42af-9950-e858adf3f3bd Norway
3f87f6c9-8b2b-4ba3-84e7-e4bf7c4dbc7c Finland
b0f1fc93-a34d-458d-8e5e-7e6c7fda2025 Netherlands
0994645c-6924-49ce-aa7d-e31f5e03f896 Germany
11a258b4-39ac-46b4-8a4c-aeed35ebf9da Denmark
7998dd24-22f6-40bf-90a9-f95105e027b1 Germany
1380dbaa-9f5b-4c5a-a7f2-568dc4c78999 Croatia
5ffe1b0a-3c9a-42c4-861e-3d907b4f9fa3 Czech Republic

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE4063AFF000XXX
E-Number (Finland):
3638196
E-Number (Norway):
4309706
EAN:
8015644007232
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.43 kg
Package Level 1 EAN:
8015644007232

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In):
63 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
630 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
44.1...63 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator